{"id":{"repo_id":"vilnius","oai_identifier":"oai:vu.lt:elaba:308325086"},"canonical_url":"https://search.ndltd.org/etd/vilnius/oai:vu.lt:elaba:308325086","repository":{"repo_id":"vilnius","name":"Vilnius University","base_url":"https://epublications.vu.lt/oai"},"display":{"title":"Ferocenu modifikuoto grafeno oksido taikymas gliukozės ir sarkozino biojutikliams kurti /","abstract":"This bachelor’s thesis focused on the development of biosensors capable of detecting sarcosine and glucose. The glucose biosensor was used as a model system for optimizing the sarcosine biosensor. Sarcosine was chosen as the analyte due to the potential link described in the literature between elevated levels of sarcosine and prostate cancer. Since prostate cancer is the most commonly diagnosed type of cancer in men worldwide, the detection of sarcosine is worthy of attention. Ferrocene-modified graphene oxide (Fc-GO) was synthesized. A graphite electrode (GE) was selected for biosensor measurements instead of a glassy carbon electrode (GCE) due to its bigger surface area. Best sensitivity was achieved with Fc-GO concentration of 12 mg/ml and the glutaraldehyde concentration of 0.5%. After 110 hours, the GE/Fc-GO/CS/HRP/SOx biosensor was deemed unsuitable for accurate sarcosine measurements. The maximum sensitivity of the biosensor, 0.62 nA/µM, was determined when the biosensor was pre-conditioned in a 50 mM KCl buffer solution prior to the first measurement. The RSD values of the glucose and sarcosine biosensors indicated that they are suitable for analyte measurement. However, a gradual decrease in response is observed, making the biosensors most suitable for single-use applications. During the selectivity study, it was found that ascorbic acid had the most significant interfering effect on the glucose biosensor, while tyrosine and ascorbic acid had the most significant interfering effects on the sarcosine biosensor. Real samples test results showed that the glucose biosensor detected a glucose concentration of 3.62 ± 1.35 mM in the HN (normal) blood serum sample and 14.21 ± 1.86 mM in HP (pathologic) samples. Meanwhile, the MEDSAN MS-2001 determined a glucose concentration of 3.72 ± 0.11 mM in the HN sample and 13.57 ± 0.41 mM in HP. The sarcosine biosensor was used to determine the sarcosine concentration in blood serum with added sarcosine solution (5 mM), in curd, and in curd with added sarcosine solution (0.05 mM). The concentration of sarcosine in blood serum was determined to be 4.56 ± 0.48 mM, in curd 0.073 ± 0.01 mM, and in curd with added sarcosine solution 0.3 mM.","abstract_html":"This bachelor’s thesis focused on the development of biosensors capable of detecting sarcosine and glucose. The glucose biosensor was used as a model system for optimizing the sarcosine biosensor. Sarcosine was chosen as the analyte due to the potential link described in the literature between elevated levels of sarcosine and prostate cancer. Since prostate cancer is the most commonly diagnosed type of cancer in men worldwide, the detection of sarcosine is worthy of attention. Ferrocene-modified graphene oxide (Fc-GO) was synthesized. A graphite electrode (GE) was selected for biosensor measurements instead of a glassy carbon electrode (GCE) due to its bigger surface area. Best sensitivity was achieved with Fc-GO concentration of 12 mg/ml and the glutaraldehyde concentration of 0.5%. After 110 hours, the GE/Fc-GO/CS/HRP/SOx biosensor was deemed unsuitable for accurate sarcosine measurements. The maximum sensitivity of the biosensor, 0.62 nA/µM, was determined when the biosensor was pre-conditioned in a 50 mM KCl buffer solution prior to the first measurement. The RSD values of the glucose and sarcosine biosensors indicated that they are suitable for analyte measurement. However, a gradual decrease in response is observed, making the biosensors most suitable for single-use applications. During the selectivity study, it was found that ascorbic acid had the most significant interfering effect on the glucose biosensor, while tyrosine and ascorbic acid had the most significant interfering effects on the sarcosine biosensor. Real samples test results showed that the glucose biosensor detected a glucose concentration of 3.62 ± 1.35 mM in the HN (normal) blood serum sample and 14.21 ± 1.86 mM in HP (pathologic) samples. Meanwhile, the MEDSAN MS-2001 determined a glucose concentration of 3.72 ± 0.11 mM in the HN sample and 13.57 ± 0.41 mM in HP. The sarcosine biosensor was used to determine the sarcosine concentration in blood serum with added sarcosine solution (5 mM), in curd, and in curd with added sarcosine solution (0.05 mM). The concentration of sarcosine in blood serum was determined to be 4.56 ± 0.48 mM, in curd 0.073 ± 0.01 mM, and in curd with added sarcosine solution 0.3 mM.","abstract_has_math":false,"creators":["Kornilova, Viktorija,"],"institution":"Institutional Repository of Vilnius University","degree_name":null,"degree_level":null,"degree_discipline":null,"degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026","date_published":"2026","updated_at":"2026-11-19T10:12:42Z","subjects":[],"languages":["lit"],"rights":["info:eu-repo/semantics/openAccess"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://repository.vu.lt/VU:ELABAETD308325086&prefLang=en_US","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://repository.vu.lt/VU:ELABAETD308325086&prefLang=en_US","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":"open","embargo_until":null,"access_note":null},"source_record":{"url":"https://epublications.vu.lt/oai?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Avu.lt%3Aelaba%3A308325086","prefix":"oai_dc"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Kornilova, Viktorija,"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026"]},{"key":"dc:publisher","label":"Institution","values":["Institutional Repository of Vilnius University"]},{"key":"dc:relation","label":"Dc Relation","values":["https://epublications.vu.lt/object/elaba:308325086/308325086.pdf"]},{"key":"dc:type","label":"Dc Type","values":["info:eu-repo/semantics/bachelorThesis"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["lit"]},{"key":"dc:rights","label":"Dc Rights","values":["info:eu-repo/semantics/openAccess"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.vu.lt/VU:ELABAETD308325086&prefLang=en_US"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["This bachelor’s thesis focused on the development of biosensors capable of detecting sarcosine and glucose. The glucose biosensor was used as a model system for optimizing the sarcosine biosensor. Sarcosine was chosen as the analyte due to the potential link described in the literature between elevated levels of sarcosine and prostate cancer. Since prostate cancer is the most commonly diagnosed type of cancer in men worldwide, the detection of sarcosine is worthy of attention. Ferrocene-modified graphene oxide (Fc-GO) was synthesized. A graphite electrode (GE) was selected for biosensor measurements instead of a glassy carbon electrode (GCE) due to its bigger surface area. Best sensitivity was achieved with Fc-GO concentration of 12 mg/ml and the glutaraldehyde concentration of 0.5%. After 110 hours, the GE/Fc-GO/CS/HRP/SOx biosensor was deemed unsuitable for accurate sarcosine measurements. The maximum sensitivity of the biosensor, 0.62 nA/µM, was determined when the biosensor was pre-conditioned in a 50 mM KCl buffer solution prior to the first measurement. The RSD values of the glucose and sarcosine biosensors indicated that they are suitable for analyte measurement. However, a gradual decrease in response is observed, making the biosensors most suitable for single-use applications. During the selectivity study, it was found that ascorbic acid had the most significant interfering effect on the glucose biosensor, while tyrosine and ascorbic acid had the most significant interfering effects on the sarcosine biosensor. Real samples test results showed that the glucose biosensor detected a glucose concentration of 3.62 ± 1.35 mM in the HN (normal) blood serum sample and 14.21 ± 1.86 mM in HP (pathologic) samples. Meanwhile, the MEDSAN MS-2001 determined a glucose concentration of 3.72 ± 0.11 mM in the HN sample and 13.57 ± 0.41 mM in HP. The sarcosine biosensor was used to determine the sarcosine concentration in blood serum with added sarcosine solution (5 mM), in curd, and in curd with added sarcosine solution (0.05 mM). The concentration of sarcosine in blood serum was determined to be 4.56 ± 0.48 mM, in curd 0.073 ± 0.01 mM, and in curd with added sarcosine solution 0.3 mM."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Ferocenu modifikuoto grafeno oksido taikymas gliukozės ir sarkozino biojutikliams kurti /","The use of ferrocene-modified graphene oxide for fabrication of glucose and sarcosine biosensors."]}]}],"canonical_facts":{"dc:creator":["Kornilova, Viktorija,"],"dc:date":["2026"],"dc:description":["This bachelor’s thesis focused on the development of biosensors capable of detecting sarcosine and glucose. The glucose biosensor was used as a model system for optimizing the sarcosine biosensor. Sarcosine was chosen as the analyte due to the potential link described in the literature between elevated levels of sarcosine and prostate cancer. Since prostate cancer is the most commonly diagnosed type of cancer in men worldwide, the detection of sarcosine is worthy of attention. Ferrocene-modified graphene oxide (Fc-GO) was synthesized. A graphite electrode (GE) was selected for biosensor measurements instead of a glassy carbon electrode (GCE) due to its bigger surface area. Best sensitivity was achieved with Fc-GO concentration of 12 mg/ml and the glutaraldehyde concentration of 0.5%. After 110 hours, the GE/Fc-GO/CS/HRP/SOx biosensor was deemed unsuitable for accurate sarcosine measurements. The maximum sensitivity of the biosensor, 0.62 nA/µM, was determined when the biosensor was pre-conditioned in a 50 mM KCl buffer solution prior to the first measurement. The RSD values of the glucose and sarcosine biosensors indicated that they are suitable for analyte measurement. However, a gradual decrease in response is observed, making the biosensors most suitable for single-use applications. During the selectivity study, it was found that ascorbic acid had the most significant interfering effect on the glucose biosensor, while tyrosine and ascorbic acid had the most significant interfering effects on the sarcosine biosensor. Real samples test results showed that the glucose biosensor detected a glucose concentration of 3.62 ± 1.35 mM in the HN (normal) blood serum sample and 14.21 ± 1.86 mM in HP (pathologic) samples. Meanwhile, the MEDSAN MS-2001 determined a glucose concentration of 3.72 ± 0.11 mM in the HN sample and 13.57 ± 0.41 mM in HP. The sarcosine biosensor was used to determine the sarcosine concentration in blood serum with added sarcosine solution (5 mM), in curd, and in curd with added sarcosine solution (0.05 mM). The concentration of sarcosine in blood serum was determined to be 4.56 ± 0.48 mM, in curd 0.073 ± 0.01 mM, and in curd with added sarcosine solution 0.3 mM."],"dc:format":["application/pdf"],"dc:identifier":["https://repository.vu.lt/VU:ELABAETD308325086&prefLang=en_US"],"dc:language":["lit"],"dc:publisher":["Institutional Repository of Vilnius University"],"dc:relation":["https://epublications.vu.lt/object/elaba:308325086/308325086.pdf"],"dc:rights":["info:eu-repo/semantics/openAccess"],"dc:title":["Ferocenu modifikuoto grafeno oksido taikymas gliukozės ir sarkozino biojutikliams kurti /","The use of ferrocene-modified graphene oxide for fabrication of glucose and sarcosine biosensors."],"dc:type":["info:eu-repo/semantics/bachelorThesis"]},"updated_at":"2026-11-19T10:12:42Z"}