{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/101256"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/101256","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Simulation and study of harmonic interference in power line communications","abstract":"Power line carrier (PLC) is one of the communication and load control (C&LC) techniques employed in direct load control. A PLC is, within itself, a communication system. It utilizes power transmission line as a medium of transmitting control functions, and relaying. High frequencies, in the order of 30 to 300 kHz, are used. Power line carrier systems are, at present, the most attractive C&LC systems. Recently, dispersed generation - photovoltaics, wind energy, small scale hydro - is introduced to power systems. The introduction of small scale dispersed generation sources degrades the performance of PLC systems by injecting dc-ac inverter related harmonics into the distribution lines. These harmonics interfere with PLC signals. Thus load control functions assigned to PLC systems are affected. It is the purpose of this research to study how a PLC signal propagates through the transmission line and how it is affected by the harmonic interference. An experiment is conducted using a distribution network provided by the Jet Propulsion Laboratory discussions, and conclusions are presented.","abstract_html":"Power line carrier (PLC) is one of the communication and load control (C&amp;LC) techniques employed in direct load control. A PLC is, within itself, a communication system. It utilizes power transmission line as a medium of transmitting control functions, and relaying. High frequencies, in the order of 30 to 300 kHz, are used. Power line carrier systems are, at present, the most attractive C&amp;LC systems. Recently, dispersed generation - photovoltaics, wind energy, small scale hydro - is introduced to power systems. The introduction of small scale dispersed generation sources degrades the performance of PLC systems by injecting dc-ac inverter related harmonics into the distribution lines. These harmonics interfere with PLC signals. Thus load control functions assigned to PLC systems are affected. It is the purpose of this research to study how a PLC signal propagates through the transmission line and how it is affected by the harmonic interference. An experiment is conducted using a distribution network provided by the Jet Propulsion Laboratory discussions, and conclusions are presented.","abstract_has_math":false,"creators":["Roongsita, Somsak"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"M.S.","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1985,"date_issued":"1985","date_published":"1985","updated_at":"2026-11-18T20:01:29Z","subjects":["Electric interference","Electric lines -- Carrier transmission"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/101256","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/101256","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F101256","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Roongsita, Somsak"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-12-14T16:35:03Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-12-14T16:35:03Z"]},{"key":"dc:date.issued","label":"Date","values":["1985"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 13868520"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1985.R666"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Electric interference","Electric lines -- Carrier transmission"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/101256"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Power line carrier (PLC) is one of the communication and load control (C&LC) techniques employed in direct load control. A PLC is, within itself, a communication system. It utilizes power transmission line as a medium of transmitting control functions, and relaying. High frequencies, in the order of 30 to 300 kHz, are used. Power line carrier systems are, at present, the most attractive C&LC systems. Recently, dispersed generation - photovoltaics, wind energy, small scale hydro - is introduced to power systems. The introduction of small scale dispersed generation sources degrades the performance of PLC systems by injecting dc-ac inverter related harmonics into the distribution lines. These harmonics interfere with PLC signals. Thus load control functions assigned to PLC systems are affected. It is the purpose of this research to study how a PLC signal propagates through the transmission line and how it is affected by the harmonic interference. An experiment is conducted using a distribution network provided by the Jet Propulsion Laboratory discussions, and conclusions are presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xi, 159 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Simulation and study of harmonic interference in power line communications"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Roongsita, Somsak"],"dc:date.accessioned":["2020-12-14T16:35:03Z"],"dc:date.available":["2020-12-14T16:35:03Z"],"dc:date.issued":["1985"],"dc:description.abstract":["Power line carrier (PLC) is one of the communication and load control (C&LC) techniques employed in direct load control. A PLC is, within itself, a communication system. It utilizes power transmission line as a medium of transmitting control functions, and relaying. High frequencies, in the order of 30 to 300 kHz, are used. Power line carrier systems are, at present, the most attractive C&LC systems. Recently, dispersed generation - photovoltaics, wind energy, small scale hydro - is introduced to power systems. The introduction of small scale dispersed generation sources degrades the performance of PLC systems by injecting dc-ac inverter related harmonics into the distribution lines. These harmonics interfere with PLC signals. Thus load control functions assigned to PLC systems are affected. It is the purpose of this research to study how a PLC signal propagates through the transmission line and how it is affected by the harmonic interference. An experiment is conducted using a distribution network provided by the Jet Propulsion Laboratory discussions, and conclusions are presented."],"dc:description.degree":["M.S."],"dc:format.extent":["xi, 159 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/101256"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 13868520"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1985.R666"],"dc:subject.lcsh":["Electric interference","Electric lines -- Carrier transmission"],"dc:title":["Simulation and study of harmonic interference in power line communications"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:01:29Z"}