{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/113490"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/113490","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Effect of phosphorus limiting conditions on process performance in activated sludge","abstract":"The effect of phosphorus limiting conditions on process performance was investigated using laboratory scale activated sludge units. Data were collected for COD:P ratios of 287:1, 212:1, 87:1 and 56:1 at several mean cell residence times. Data collected at COD:P ratios of 287:1 and 212:1 produced sludge with extremely poor settling characteristics and data were collected for only one mean cell residence time at each ratio; Data for COD:P ratios of 87:1 and 56:1 were used to estimate kinetic coefficients. These kinetic coefficients were used to develop predicted values of process performance subject to phosphorus limiting conditions utilizing mathematical and stoichiometric relationships. Predicted values were compared to laboratory data. For both predicted values and laboratory data, a phosphorus limitation resulted in decreased COD removal efficiency, nearly 100 percent phosphorus removal efficiency, decreased reactor solids concentrations, solids with poor settling characteristics, decreased sludge production and artificially high F/M ratios.","abstract_html":"The effect of phosphorus limiting conditions on process performance was investigated using laboratory scale activated sludge units. Data were collected for COD:P ratios of 287:1, 212:1, 87:1 and 56:1 at several mean cell residence times. Data collected at COD:P ratios of 287:1 and 212:1 produced sludge with extremely poor settling characteristics and data were collected for only one mean cell residence time at each ratio; Data for COD:P ratios of 87:1 and 56:1 were used to estimate kinetic coefficients. These kinetic coefficients were used to develop predicted values of process performance subject to phosphorus limiting conditions utilizing mathematical and stoichiometric relationships. Predicted values were compared to laboratory data. For both predicted values and laboratory data, a phosphorus limitation resulted in decreased COD removal efficiency, nearly 100 percent phosphorus removal efficiency, decreased reactor solids concentrations, solids with poor settling characteristics, decreased sludge production and artificially high F/M ratios.","abstract_has_math":false,"creators":["Hawkins, James M. (James Meade)"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"M.S.","degree_level":"masters","degree_discipline":"Sanitary Engineering","degree_department":"Sanitary Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1983,"date_issued":"1983","date_published":"1983","updated_at":"2026-11-18T20:22:59Z","subjects":["Sewage -- Purification -- Activated sludge process","Sewage -- Purification -- Organic compounds removal"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/113490","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/113490","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F113490","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Sanitary Engineering"]},{"key":"dc:creator","label":"Author","values":["Hawkins, James M. (James Meade)"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-01-27T04:47:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-01-27T04:47:47Z"]},{"key":"dc:date.issued","label":"Date","values":["1983"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 11100019"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Sanitary Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1983.H383"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Sewage -- Purification -- Activated sludge process","Sewage -- Purification -- Organic compounds removal"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/113490"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The effect of phosphorus limiting conditions on process performance was investigated using laboratory scale activated sludge units. Data were collected for COD:P ratios of 287:1, 212:1, 87:1 and 56:1 at several mean cell residence times. Data collected at COD:P ratios of 287:1 and 212:1 produced sludge with extremely poor settling characteristics and data were collected for only one mean cell residence time at each ratio; Data for COD:P ratios of 87:1 and 56:1 were used to estimate kinetic coefficients. These kinetic coefficients were used to develop predicted values of process performance subject to phosphorus limiting conditions utilizing mathematical and stoichiometric relationships. Predicted values were compared to laboratory data. For both predicted values and laboratory data, a phosphorus limitation resulted in decreased COD removal efficiency, nearly 100 percent phosphorus removal efficiency, decreased reactor solids concentrations, solids with poor settling characteristics, decreased sludge production and artificially high F/M ratios."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 101 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Effect of phosphorus limiting conditions on process performance in activated sludge"]}]}],"canonical_facts":{"dc:contributor.department":["Sanitary Engineering"],"dc:creator":["Hawkins, James M. (James Meade)"],"dc:date.accessioned":["2023-01-27T04:47:47Z"],"dc:date.available":["2023-01-27T04:47:47Z"],"dc:date.issued":["1983"],"dc:description.abstract":["The effect of phosphorus limiting conditions on process performance was investigated using laboratory scale activated sludge units. Data were collected for COD:P ratios of 287:1, 212:1, 87:1 and 56:1 at several mean cell residence times. Data collected at COD:P ratios of 287:1 and 212:1 produced sludge with extremely poor settling characteristics and data were collected for only one mean cell residence time at each ratio; Data for COD:P ratios of 87:1 and 56:1 were used to estimate kinetic coefficients. These kinetic coefficients were used to develop predicted values of process performance subject to phosphorus limiting conditions utilizing mathematical and stoichiometric relationships. Predicted values were compared to laboratory data. For both predicted values and laboratory data, a phosphorus limitation resulted in decreased COD removal efficiency, nearly 100 percent phosphorus removal efficiency, decreased reactor solids concentrations, solids with poor settling characteristics, decreased sludge production and artificially high F/M ratios."],"dc:description.degree":["M.S."],"dc:format.extent":["ix, 101 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["http://hdl.handle.net/10919/113490"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 11100019"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1983.H383"],"dc:subject.lcsh":["Sewage -- Purification -- Activated sludge process","Sewage -- Purification -- Organic compounds removal"],"dc:title":["Effect of phosphorus limiting conditions on process performance in activated sludge"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Sanitary Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:22:59Z"}