{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/116111"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/116111","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The Chondroid Conundrum: Transpharyngeal Removal of Guttural Pouch Chondroids in Horses","abstract":"Removal of chondroids from the guttural pouches (GP) of affected horses is essential to prevent asymptomatic transmission of Strangles (Streptococcus equi subsp equi). Current chondroid removal via endoscopic basket or percutaneous surgery has limitations, including time, cost and complications. Dorsal pharyngeal recess (DPR) fenestration of the GP using transendoscopic laser is minimally invasive, but has not been optimized for removal of GP chondroids. Our objective was to determine if a 3D-printed instrument improved lavage efficacy for chondroid removal from a dorsal pharyngeal recess (DPR) fenestration, and to compare instrument placement directly through the DPR fenestration vs. through the SPO. We hypothesized that: 1) use of a 3D-printed instrument would recover more prostheses, reduce lavage time, and incur less soft tissue damage than lavage alone; and 2) that 3D-printed instrument placement through the DPR would recover more prostheses, reduce lavage time, and incur in less soft tissue damage than placement through the salpingopharyngeal ostium (SPO) in equine cadaveric heads. Procedures to remove 50 plastic 12 mm bead prostheses from the GP were randomized for 10 repeats: DPR+3D: 3D-printed instrument via DPR; DPR-3D: lavage via DPR; SPO+3D: 3D-printed instrument via SPO; SPO-3D: lavage via SPO. Lavage was administered in 2-minute cycles via 3D-printed instrument or tubing control. Bead recovery and rate to remove ≥96% or 3 consecutive no-yield cycles was recorded. Soft tissue damage was graded via endoscopy. Data were compared by GEE model and Fisher's exact test (p < 0.05). Median laser surgery time was 1225 seconds (range 563-2400 seconds). 3D-printed instrument chondroid removal procedures recovered significantly more beads (median 48 beads; range 0-49) and were significantly faster (median 24 beads/cycle; range 12-50) than lavage alone (median 6 beads/cycle; range 0-29 and 0.66 beads/cycle, range 0-49). There was no difference when the 3D-printed instrument was used through the DPR fenestration or SPO. Superficial mucosal damage occurred after 43.4% of fenestrations. Post-procedure, there was no difference in soft tissue damage between procedures (30.4% of heads). Use of the custom 3D-printed instrument efficiently removed GP chondroids through a DPR fenestration when used either through the fenestration or via the SPO. It may be a viable treatment alternative to current techniques and warrants testing in live horses.","abstract_html":"Removal of chondroids from the guttural pouches (GP) of affected horses is essential to prevent asymptomatic transmission of Strangles (Streptococcus equi subsp equi). Current chondroid removal via endoscopic basket or percutaneous surgery has limitations, including time, cost and complications. Dorsal pharyngeal recess (DPR) fenestration of the GP using transendoscopic laser is minimally invasive, but has not been optimized for removal of GP chondroids. Our objective was to determine if a 3D-printed instrument improved lavage efficacy for chondroid removal from a dorsal pharyngeal recess (DPR) fenestration, and to compare instrument placement directly through the DPR fenestration vs. through the SPO. We hypothesized that: 1) use of a 3D-printed instrument would recover more prostheses, reduce lavage time, and incur less soft tissue damage than lavage alone; and 2) that 3D-printed instrument placement through the DPR would recover more prostheses, reduce lavage time, and incur in less soft tissue damage than placement through the salpingopharyngeal ostium (SPO) in equine cadaveric heads. Procedures to remove 50 plastic 12 mm bead prostheses from the GP were randomized for 10 repeats: DPR+3D: 3D-printed instrument via DPR; DPR-3D: lavage via DPR; SPO+3D: 3D-printed instrument via SPO; SPO-3D: lavage via SPO. Lavage was administered in 2-minute cycles via 3D-printed instrument or tubing control. Bead recovery and rate to remove ≥96% or 3 consecutive no-yield cycles was recorded. Soft tissue damage was graded via endoscopy. Data were compared by GEE model and Fisher&#x27;s exact test (p &lt; 0.05). Median laser surgery time was 1225 seconds (range 563-2400 seconds). 3D-printed instrument chondroid removal procedures recovered significantly more beads (median 48 beads; range 0-49) and were significantly faster (median 24 beads/cycle; range 12-50) than lavage alone (median 6 beads/cycle; range 0-29 and 0.66 beads/cycle, range 0-49). There was no difference when the 3D-printed instrument was used through the DPR fenestration or SPO. Superficial mucosal damage occurred after 43.4% of fenestrations. Post-procedure, there was no difference in soft tissue damage between procedures (30.4% of heads). Use of the custom 3D-printed instrument efficiently removed GP chondroids through a DPR fenestration when used either through the fenestration or via the SPO. It may be a viable treatment alternative to current techniques and warrants testing in live horses.","abstract_has_math":false,"creators":["Cardona, Guillermo Andres"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Biomedical and Veterinary Sciences","degree_department":"Biomedical and Veterinary Sciences","school":null,"contributors":[],"advisors":[],"committee_chairs":["Bogers, Sophie Helen"],"committee_members":["Byron, Christopher R.","Dahlgren, Linda A.","McKenzie, Harold C."],"year":2023,"date_issued":"2023-08-18","date_published":"2023-08-18","updated_at":"2026-11-18T20:06:04Z","subjects":["Guttural pouch","chondroids","laser surgery","upper airway surgery","Streptococcus equi"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:38288"],"render_values":[{"text":"vt_gsexam:38288","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/116111","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/116111","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F116111","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Bogers, Sophie Helen"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Byron, Christopher R.","Dahlgren, Linda A.","McKenzie, Harold C."]},{"key":"dc:contributor.department","label":"Department","values":["Biomedical and Veterinary Sciences"]},{"key":"dc:creator","label":"Author","values":["Cardona, Guillermo Andres"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2023-08-25T08:00:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2023-08-25T08:00:45Z"]},{"key":"dc:date.issued","label":"Date","values":["2023-08-18"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Biomedical and Veterinary Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Guttural pouch","chondroids","laser surgery","upper airway surgery","Streptococcus equi"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:38288"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/116111"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Removal of chondroids from the guttural pouches (GP) of affected horses is essential to prevent asymptomatic transmission of Strangles (Streptococcus equi subsp equi). Current chondroid removal via endoscopic basket or percutaneous surgery has limitations, including time, cost and complications. Dorsal pharyngeal recess (DPR) fenestration of the GP using transendoscopic laser is minimally invasive, but has not been optimized for removal of GP chondroids. Our objective was to determine if a 3D-printed instrument improved lavage efficacy for chondroid removal from a dorsal pharyngeal recess (DPR) fenestration, and to compare instrument placement directly through the DPR fenestration vs. through the SPO. We hypothesized that: 1) use of a 3D-printed instrument would recover more prostheses, reduce lavage time, and incur less soft tissue damage than lavage alone; and 2) that 3D-printed instrument placement through the DPR would recover more prostheses, reduce lavage time, and incur in less soft tissue damage than placement through the salpingopharyngeal ostium (SPO) in equine cadaveric heads. Procedures to remove 50 plastic 12 mm bead prostheses from the GP were randomized for 10 repeats: DPR+3D: 3D-printed instrument via DPR; DPR-3D: lavage via DPR; SPO+3D: 3D-printed instrument via SPO; SPO-3D: lavage via SPO. Lavage was administered in 2-minute cycles via 3D-printed instrument or tubing control. Bead recovery and rate to remove ≥96% or 3 consecutive no-yield cycles was recorded. Soft tissue damage was graded via endoscopy. Data were compared by GEE model and Fisher's exact test (p < 0.05). Median laser surgery time was 1225 seconds (range 563-2400 seconds). 3D-printed instrument chondroid removal procedures recovered significantly more beads (median 48 beads; range 0-49) and were significantly faster (median 24 beads/cycle; range 12-50) than lavage alone (median 6 beads/cycle; range 0-29 and 0.66 beads/cycle, range 0-49). There was no difference when the 3D-printed instrument was used through the DPR fenestration or SPO. Superficial mucosal damage occurred after 43.4% of fenestrations. Post-procedure, there was no difference in soft tissue damage between procedures (30.4% of heads). Use of the custom 3D-printed instrument efficiently removed GP chondroids through a DPR fenestration when used either through the fenestration or via the SPO. It may be a viable treatment alternative to current techniques and warrants testing in live horses."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Strangles is an extremely infectious disease of horses that has negative financial and health consequences. After infection, some horses form balls of concrete-like pus in a structure in an air-filled sac of the ear canal called guttural pouches (GPs). These concretions, called chondroids, allow affected horses to continue to pass on infection to other horses. Removal of chondroids is needed to stop disease transmission but current non-surgical and surgical removal techniques have limitations. Surgical laser passed through an endoscope (medical camera) allows minimally invasive surgery of the guttural pouches. We performed laser surgery on cadaver horse heads to create access to the GP, then evaluated our ability to remove chondroid-like beads from the GP using a custom-made 3D-printed instrument. Our results showed efficient and complete removal of the beads compared to lavage without the 3D-printed instrument, with little damage to the heads. These findings are an initial step to development of a new chondroid-removal technique and may allow surgeons to more efficiently remove chondroids without the need for invasive surgery."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["The Chondroid Conundrum: Transpharyngeal Removal of Guttural Pouch Chondroids in Horses"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Bogers, Sophie Helen"],"dc:contributor.committeemember":["Byron, Christopher R.","Dahlgren, Linda A.","McKenzie, Harold C."],"dc:contributor.department":["Biomedical and Veterinary Sciences"],"dc:creator":["Cardona, Guillermo Andres"],"dc:date.accessioned":["2023-08-25T08:00:45Z"],"dc:date.available":["2023-08-25T08:00:45Z"],"dc:date.issued":["2023-08-18"],"dc:description.abstract":["Removal of chondroids from the guttural pouches (GP) of affected horses is essential to prevent asymptomatic transmission of Strangles (Streptococcus equi subsp equi). Current chondroid removal via endoscopic basket or percutaneous surgery has limitations, including time, cost and complications. Dorsal pharyngeal recess (DPR) fenestration of the GP using transendoscopic laser is minimally invasive, but has not been optimized for removal of GP chondroids. Our objective was to determine if a 3D-printed instrument improved lavage efficacy for chondroid removal from a dorsal pharyngeal recess (DPR) fenestration, and to compare instrument placement directly through the DPR fenestration vs. through the SPO. We hypothesized that: 1) use of a 3D-printed instrument would recover more prostheses, reduce lavage time, and incur less soft tissue damage than lavage alone; and 2) that 3D-printed instrument placement through the DPR would recover more prostheses, reduce lavage time, and incur in less soft tissue damage than placement through the salpingopharyngeal ostium (SPO) in equine cadaveric heads. Procedures to remove 50 plastic 12 mm bead prostheses from the GP were randomized for 10 repeats: DPR+3D: 3D-printed instrument via DPR; DPR-3D: lavage via DPR; SPO+3D: 3D-printed instrument via SPO; SPO-3D: lavage via SPO. Lavage was administered in 2-minute cycles via 3D-printed instrument or tubing control. Bead recovery and rate to remove ≥96% or 3 consecutive no-yield cycles was recorded. Soft tissue damage was graded via endoscopy. Data were compared by GEE model and Fisher's exact test (p < 0.05). Median laser surgery time was 1225 seconds (range 563-2400 seconds). 3D-printed instrument chondroid removal procedures recovered significantly more beads (median 48 beads; range 0-49) and were significantly faster (median 24 beads/cycle; range 12-50) than lavage alone (median 6 beads/cycle; range 0-29 and 0.66 beads/cycle, range 0-49). There was no difference when the 3D-printed instrument was used through the DPR fenestration or SPO. Superficial mucosal damage occurred after 43.4% of fenestrations. Post-procedure, there was no difference in soft tissue damage between procedures (30.4% of heads). Use of the custom 3D-printed instrument efficiently removed GP chondroids through a DPR fenestration when used either through the fenestration or via the SPO. It may be a viable treatment alternative to current techniques and warrants testing in live horses."],"dc:description.abstractgeneral":["Strangles is an extremely infectious disease of horses that has negative financial and health consequences. After infection, some horses form balls of concrete-like pus in a structure in an air-filled sac of the ear canal called guttural pouches (GPs). These concretions, called chondroids, allow affected horses to continue to pass on infection to other horses. Removal of chondroids is needed to stop disease transmission but current non-surgical and surgical removal techniques have limitations. Surgical laser passed through an endoscope (medical camera) allows minimally invasive surgery of the guttural pouches. We performed laser surgery on cadaver horse heads to create access to the GP, then evaluated our ability to remove chondroid-like beads from the GP using a custom-made 3D-printed instrument. Our results showed efficient and complete removal of the beads compared to lavage without the 3D-printed instrument, with little damage to the heads. These findings are an initial step to development of a new chondroid-removal technique and may allow surgeons to more efficiently remove chondroids without the need for invasive surgery."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:38288"],"dc:identifier.uri":["http://hdl.handle.net/10919/116111"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Guttural pouch","chondroids","laser surgery","upper airway surgery","Streptococcus equi"],"dc:title":["The Chondroid Conundrum: Transpharyngeal Removal of Guttural Pouch Chondroids in Horses"],"dc:type":["Thesis"],"thesis:degree_discipline":["Biomedical and Veterinary Sciences"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:06:04Z"}