{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/118360"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/118360","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Heat transfer between a shallow fluidized bed and a single horizontal tube immersed in the bed","abstract":"The heat transfer coefficient between a horizontal tube and a shallow fluidized bed of alumina particles (335-1261 micron) was measured, and the effects of the tube elevation (10-40 mm), static bed height (10-40 mm), and the design of the distributor were investigated. The cloud zone effect i.e. a sudden increase of the heat transfer coefficient when the tube was located right above the static bed height, has been verified as a feature of shallow bed systems; furthermore, the jet region has shown a dominant effect on the behavior of the shallow bed heat transfer. The results showed that the heat transfer coefficient increased monotonically with increasing air velocity when the tube was located in the jet region, and the heat transfer coefficient increased when a distributor which induced a deeper jet penetration was used. However, the erosion problem and the relatively high pressure drop across the distributor still need to be solved in further studies, so that the greatest economic value of a shallow bed can be achieved.","abstract_html":"The heat transfer coefficient between a horizontal tube and a shallow fluidized bed of alumina particles (335-1261 micron) was measured, and the effects of the tube elevation (10-40 mm), static bed height (10-40 mm), and the design of the distributor were investigated. The cloud zone effect i.e. a sudden increase of the heat transfer coefficient when the tube was located right above the static bed height, has been verified as a feature of shallow bed systems; furthermore, the jet region has shown a dominant effect on the behavior of the shallow bed heat transfer. The results showed that the heat transfer coefficient increased monotonically with increasing air velocity when the tube was located in the jet region, and the heat transfer coefficient increased when a distributor which induced a deeper jet penetration was used. However, the erosion problem and the relatively high pressure drop across the distributor still need to be solved in further studies, so that the greatest economic value of a shallow bed can be achieved.","abstract_has_math":false,"creators":["Huang, Hao-Hsin"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"M. S.","degree_level":"masters","degree_discipline":"Chemical Engineering","degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1983,"date_issued":"1983","date_published":"1983","updated_at":"2026-11-18T20:16:41Z","subjects":["Fluidized-bed furnaces","Heat -- Transmission"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/118360","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/118360","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F118360","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Huang, Hao-Hsin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2024-03-12T20:23:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2024-03-12T20:23:28Z"]},{"key":"dc:date.issued","label":"Date","values":["1983"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 10835832"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M. S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1983.H825"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Fluidized-bed furnaces","Heat -- Transmission"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/118360"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The heat transfer coefficient between a horizontal tube and a shallow fluidized bed of alumina particles (335-1261 micron) was measured, and the effects of the tube elevation (10-40 mm), static bed height (10-40 mm), and the design of the distributor were investigated. The cloud zone effect i.e. a sudden increase of the heat transfer coefficient when the tube was located right above the static bed height, has been verified as a feature of shallow bed systems; furthermore, the jet region has shown a dominant effect on the behavior of the shallow bed heat transfer. The results showed that the heat transfer coefficient increased monotonically with increasing air velocity when the tube was located in the jet region, and the heat transfer coefficient increased when a distributor which induced a deeper jet penetration was used. However, the erosion problem and the relatively high pressure drop across the distributor still need to be solved in further studies, so that the greatest economic value of a shallow bed can be achieved."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M. S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["x, 152 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Heat transfer between a shallow fluidized bed and a single horizontal tube immersed in the bed"]}]}],"canonical_facts":{"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Huang, Hao-Hsin"],"dc:date.accessioned":["2024-03-12T20:23:28Z"],"dc:date.available":["2024-03-12T20:23:28Z"],"dc:date.issued":["1983"],"dc:description.abstract":["The heat transfer coefficient between a horizontal tube and a shallow fluidized bed of alumina particles (335-1261 micron) was measured, and the effects of the tube elevation (10-40 mm), static bed height (10-40 mm), and the design of the distributor were investigated. The cloud zone effect i.e. a sudden increase of the heat transfer coefficient when the tube was located right above the static bed height, has been verified as a feature of shallow bed systems; furthermore, the jet region has shown a dominant effect on the behavior of the shallow bed heat transfer. The results showed that the heat transfer coefficient increased monotonically with increasing air velocity when the tube was located in the jet region, and the heat transfer coefficient increased when a distributor which induced a deeper jet penetration was used. However, the erosion problem and the relatively high pressure drop across the distributor still need to be solved in further studies, so that the greatest economic value of a shallow bed can be achieved."],"dc:description.degree":["M. S."],"dc:format.extent":["x, 152 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10919/118360"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 10835832"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1983.H825"],"dc:subject.lcsh":["Fluidized-bed furnaces","Heat -- Transmission"],"dc:title":["Heat transfer between a shallow fluidized bed and a single horizontal tube immersed in the bed"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M. S."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:16:41Z"}