{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/139991"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/139991","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Diffusion coefficients for carbon dioxide in aqueous CMS solutions","abstract":"The purpose of this investigation was to (1) adapt the compensated Warburg syringe manometer to measure the diffusion of gases into liquids; (2) to evaluate the accuracy of this apparatus using the carbon dioxide - water system; (3) to obtain diffusion coefficients on a system lacking data using the Warburg syringe manometer. The method used in this study consisted of imposing a known concentration change of solute gas on a quiescent liquid. Using Fick’s second law integrated for a quiescent liquid system, the molecular diffusivity was determined from direct measurements of the volume of gas absorbed at constant pressure as a function of time. The diffusion coefficient for the carbon dioxide - water system at 25°C was found to be 2.047 ± 0,186 x 10<sup>-5</sup> cm<sup>2</sup>/sec. This value is 3.91 per cent higher than a best estimate of 1.97 x 10<sup>-5</sup> cm<sup>2</sup>/sec for this system. The compensated syringe manometer was used satisfactorily to determine the diffusion coefficients of carbon dioxide in aqueous CMC solutions at 25°C. The experimentally measured diffusion coefficients were 1.847 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.25 per cent CMC, 1.807 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.50 per cent CMC, 1.695 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.75 per cent CMC, 1.868 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 1.00 per cent CMC, and 1.541 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 1.50 per cent CMC.","abstract_html":"The purpose of this investigation was to (1) adapt the compensated Warburg syringe manometer to measure the diffusion of gases into liquids; (2) to evaluate the accuracy of this apparatus using the carbon dioxide - water system; (3) to obtain diffusion coefficients on a system lacking data using the Warburg syringe manometer. The method used in this study consisted of imposing a known concentration change of solute gas on a quiescent liquid. Using Fick’s second law integrated for a quiescent liquid system, the molecular diffusivity was determined from direct measurements of the volume of gas absorbed at constant pressure as a function of time. The diffusion coefficient for the carbon dioxide - water system at 25°C was found to be 2.047 ± 0,186 x 10&lt;sup&gt;-5&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;/sec. This value is 3.91 per cent higher than a best estimate of 1.97 x 10&lt;sup&gt;-5&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;/sec for this system. The compensated syringe manometer was used satisfactorily to determine the diffusion coefficients of carbon dioxide in aqueous CMC solutions at 25°C. The experimentally measured diffusion coefficients were 1.847 x 10&lt;sup&gt;-5&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;/sec for 0.25 per cent CMC, 1.807 x 10&lt;sup&gt;-5&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;/sec for 0.50 per cent CMC, 1.695 x 10&lt;sup&gt;-5&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;/sec for 0.75 per cent CMC, 1.868 x 10&lt;sup&gt;-5&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;/sec for 1.00 per cent CMC, and 1.541 x 10&lt;sup&gt;-5&lt;/sup&gt; cm&lt;sup&gt;2&lt;/sup&gt;/sec for 1.50 per cent CMC.","abstract_has_math":false,"creators":["Watson, Charles Eugene"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"M.S.","degree_level":"masters","degree_discipline":"Chemical Engineering","degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Caskey, J. A."],"committee_members":["Naworski, J. S. Jr.","Wightman, J. P.","McGee, H. A. Jr."],"year":1971,"date_issued":"1971","date_published":"1971","updated_at":"2026-11-18T20:14:46Z","subjects":["Carbon dioxide"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/139991","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/139991","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F139991","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Caskey, J. A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Naworski, J. S. Jr.","Wightman, J. P.","McGee, H. A. Jr."]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Watson, Charles Eugene"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2025-12-17T16:48:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-17T16:48:41Z"]},{"key":"dc:date.issued","label":"Date","values":["1971"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 2049376"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1971.W38"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Carbon dioxide"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/139991"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this investigation was to (1) adapt the compensated Warburg syringe manometer to measure the diffusion of gases into liquids; (2) to evaluate the accuracy of this apparatus using the carbon dioxide - water system; (3) to obtain diffusion coefficients on a system lacking data using the Warburg syringe manometer. The method used in this study consisted of imposing a known concentration change of solute gas on a quiescent liquid. Using Fick’s second law integrated for a quiescent liquid system, the molecular diffusivity was determined from direct measurements of the volume of gas absorbed at constant pressure as a function of time. The diffusion coefficient for the carbon dioxide - water system at 25°C was found to be 2.047 ± 0,186 x 10<sup>-5</sup> cm<sup>2</sup>/sec. This value is 3.91 per cent higher than a best estimate of 1.97 x 10<sup>-5</sup> cm<sup>2</sup>/sec for this system. The compensated syringe manometer was used satisfactorily to determine the diffusion coefficients of carbon dioxide in aqueous CMC solutions at 25°C. The experimentally measured diffusion coefficients were 1.847 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.25 per cent CMC, 1.807 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.50 per cent CMC, 1.695 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.75 per cent CMC, 1.868 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 1.00 per cent CMC, and 1.541 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 1.50 per cent CMC."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xii, 182 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Diffusion coefficients for carbon dioxide in aqueous CMS solutions"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Caskey, J. A."],"dc:contributor.committeemember":["Naworski, J. S. Jr.","Wightman, J. P.","McGee, H. A. Jr."],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Watson, Charles Eugene"],"dc:date.accessioned":["2025-12-17T16:48:41Z"],"dc:date.available":["2025-12-17T16:48:41Z"],"dc:date.issued":["1971"],"dc:description.abstract":["The purpose of this investigation was to (1) adapt the compensated Warburg syringe manometer to measure the diffusion of gases into liquids; (2) to evaluate the accuracy of this apparatus using the carbon dioxide - water system; (3) to obtain diffusion coefficients on a system lacking data using the Warburg syringe manometer. The method used in this study consisted of imposing a known concentration change of solute gas on a quiescent liquid. Using Fick’s second law integrated for a quiescent liquid system, the molecular diffusivity was determined from direct measurements of the volume of gas absorbed at constant pressure as a function of time. The diffusion coefficient for the carbon dioxide - water system at 25°C was found to be 2.047 ± 0,186 x 10<sup>-5</sup> cm<sup>2</sup>/sec. This value is 3.91 per cent higher than a best estimate of 1.97 x 10<sup>-5</sup> cm<sup>2</sup>/sec for this system. The compensated syringe manometer was used satisfactorily to determine the diffusion coefficients of carbon dioxide in aqueous CMC solutions at 25°C. The experimentally measured diffusion coefficients were 1.847 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.25 per cent CMC, 1.807 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.50 per cent CMC, 1.695 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 0.75 per cent CMC, 1.868 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 1.00 per cent CMC, and 1.541 x 10<sup>-5</sup> cm<sup>2</sup>/sec for 1.50 per cent CMC."],"dc:description.degree":["M.S."],"dc:format.extent":["xii, 182 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10919/139991"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 2049376"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1971.W38"],"dc:subject.lcsh":["Carbon dioxide"],"dc:title":["Diffusion coefficients for carbon dioxide in aqueous CMS solutions"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:14:46Z"}