{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/141374"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/141374","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Temperatures and turbulence effects upon stochastic model for dissolved oxygen and pollution in stream","abstract":"The parameter (T) used to estimate BOD and dissolved oxygen variances in streams in the statistical model proposed by Thayer and Krutchkoff was investigated. The effects of temperature and turbulence upon 6 were evaluated. Dissolved oxygen sag curves for various initial conditions of temperature and turbulence were developed through laboratory experiments and a value of 6 was calculated for each. Curves relating 6 to temperature and turbulence showed the relationship to be of a physical nature formulated as: T = .08 + .007T - .00061G The equation arrived at in this study may be used to calculate 6 for an initial temperature and turbulence conditions in a stream In turn, probabilities of having a certain BOD or dissolved oxygen concentration for a given point in time downstream may be calculated via the statistical model.","abstract_html":"The parameter (T) used to estimate BOD and dissolved oxygen variances in streams in the statistical model proposed by Thayer and Krutchkoff was investigated. The effects of temperature and turbulence upon 6 were evaluated. Dissolved oxygen sag curves for various initial conditions of temperature and turbulence were developed through laboratory experiments and a value of 6 was calculated for each. Curves relating 6 to temperature and turbulence showed the relationship to be of a physical nature formulated as: T = .08 + .007T - .00061G The equation arrived at in this study may be used to calculate 6 for an initial temperature and turbulence conditions in a stream In turn, probabilities of having a certain BOD or dissolved oxygen concentration for a given point in time downstream may be calculated via the statistical model.","abstract_has_math":false,"creators":["Bosley, Joseph Robert"],"institution":"Virginia Polytechnic Institute","degree_name":"M.S.","degree_level":"masters","degree_discipline":"Sanitary Engineering","degree_department":"Sanitary Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Cibulka, J. J."],"committee_members":["King, P. H.","Krutchkoff, R. G."],"year":1969,"date_issued":"1969","date_published":"1969","updated_at":"2026-11-18T20:12:05Z","subjects":["Thermal pollution of rivers, lakes, etc","Water -- Pollution"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/141374","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/141374","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F141374","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Cibulka, J. J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["King, P. H.","Krutchkoff, R. G."]},{"key":"dc:contributor.department","label":"Department","values":["Sanitary Engineering"]},{"key":"dc:creator","label":"Author","values":["Bosley, Joseph Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-02-20T22:46:39Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-02-20T22:46:39Z"]},{"key":"dc:date.issued","label":"Date","values":["1969"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 20510828"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Sanitary Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1969.B67"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Thermal pollution of rivers, lakes, etc","Water -- Pollution"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/141374"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The parameter (T) used to estimate BOD and dissolved oxygen variances in streams in the statistical model proposed by Thayer and Krutchkoff was investigated. The effects of temperature and turbulence upon 6 were evaluated. Dissolved oxygen sag curves for various initial conditions of temperature and turbulence were developed through laboratory experiments and a value of 6 was calculated for each. Curves relating 6 to temperature and turbulence showed the relationship to be of a physical nature formulated as: T = .08 + .007T - .00061G The equation arrived at in this study may be used to calculate 6 for an initial temperature and turbulence conditions in a stream In turn, probabilities of having a certain BOD or dissolved oxygen concentration for a given point in time downstream may be calculated via the statistical model."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["iv, 38 leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Temperatures and turbulence effects upon stochastic model for dissolved oxygen and pollution in stream"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Cibulka, J. J."],"dc:contributor.committeemember":["King, P. H.","Krutchkoff, R. G."],"dc:contributor.department":["Sanitary Engineering"],"dc:creator":["Bosley, Joseph Robert"],"dc:date.accessioned":["2026-02-20T22:46:39Z"],"dc:date.available":["2026-02-20T22:46:39Z"],"dc:date.issued":["1969"],"dc:description.abstract":["The parameter (T) used to estimate BOD and dissolved oxygen variances in streams in the statistical model proposed by Thayer and Krutchkoff was investigated. The effects of temperature and turbulence upon 6 were evaluated. Dissolved oxygen sag curves for various initial conditions of temperature and turbulence were developed through laboratory experiments and a value of 6 was calculated for each. Curves relating 6 to temperature and turbulence showed the relationship to be of a physical nature formulated as: T = .08 + .007T - .00061G The equation arrived at in this study may be used to calculate 6 for an initial temperature and turbulence conditions in a stream In turn, probabilities of having a certain BOD or dissolved oxygen concentration for a given point in time downstream may be calculated via the statistical model."],"dc:description.degree":["M.S."],"dc:format.extent":["iv, 38 leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10919/141374"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute"],"dc:relation.isformatof":["OCLC# 20510828"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1969.B67"],"dc:subject.lcsh":["Thermal pollution of rivers, lakes, etc","Water -- Pollution"],"dc:title":["Temperatures and turbulence effects upon stochastic model for dissolved oxygen and pollution in stream"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Sanitary Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Virginia Polytechnic Institute"]},"updated_at":"2026-11-18T20:12:05Z"}