{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/141419"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/141419","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Selected factors affecting oxidation of manganese (II) by ozone","abstract":"The series of experiments reported in this research was concerned with the oxidation of manganese (II) by ozone under conditions of variable pH and alkalinity. The experiments were conducted using a bench scale batch reactor to facilitate ozonation followed by filtration. The results of the experiment indicated that for a specified water source, pH and alkalinity within the ranges studied did not measurably affect the rate of oxidation of soluble manganese. The manganese exhibited a tendency to resolubilize upon overdosage with ozone, probably due to formation of the permanganate ion. Drinking water standards for manganese can be effectively met upon subsequent filtration if overdosing of ozone is avoided. The oxidation kinetics were rapid in that a contact period of one minute and an ozone dosage of 1.5 mg/1 were sufficient to provide satisfactory oxidation and subsequent removal of manganese (II).","abstract_html":"The series of experiments reported in this research was concerned with the oxidation of manganese (II) by ozone under conditions of variable pH and alkalinity. The experiments were conducted using a bench scale batch reactor to facilitate ozonation followed by filtration. The results of the experiment indicated that for a specified water source, pH and alkalinity within the ranges studied did not measurably affect the rate of oxidation of soluble manganese. The manganese exhibited a tendency to resolubilize upon overdosage with ozone, probably due to formation of the permanganate ion. Drinking water standards for manganese can be effectively met upon subsequent filtration if overdosing of ozone is avoided. The oxidation kinetics were rapid in that a contact period of one minute and an ozone dosage of 1.5 mg/1 were sufficient to provide satisfactory oxidation and subsequent removal of manganese (II).","abstract_has_math":false,"creators":["Jensen, David Marc"],"institution":"Virginia Polytechnic Institute and State University","degree_name":"M.S.","degree_level":"masters","degree_discipline":"Sanitary Engineering","degree_department":"Sanitary Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["King, Paul H."],"committee_members":["Hoehn, Robert C.","Boardman, Gregory D."],"year":1979,"date_issued":"1979","date_published":"1979","updated_at":"2026-11-18T20:16:14Z","subjects":["Manganese"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/141419","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/141419","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F141419","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["King, Paul H."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Hoehn, Robert C.","Boardman, Gregory D."]},{"key":"dc:contributor.department","label":"Department","values":["Sanitary Engineering"]},{"key":"dc:creator","label":"Author","values":["Jensen, David Marc"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-02-20T22:46:50Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-02-20T22:46:50Z"]},{"key":"dc:date.issued","label":"Date","values":["1979"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Polytechnic Institute and State University"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 05524680"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Sanitary Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["M.S."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1979.J458"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Manganese"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/141419"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The series of experiments reported in this research was concerned with the oxidation of manganese (II) by ozone under conditions of variable pH and alkalinity. The experiments were conducted using a bench scale batch reactor to facilitate ozonation followed by filtration. The results of the experiment indicated that for a specified water source, pH and alkalinity within the ranges studied did not measurably affect the rate of oxidation of soluble manganese. The manganese exhibited a tendency to resolubilize upon overdosage with ozone, probably due to formation of the permanganate ion. Drinking water standards for manganese can be effectively met upon subsequent filtration if overdosing of ozone is avoided. The oxidation kinetics were rapid in that a contact period of one minute and an ozone dosage of 1.5 mg/1 were sufficient to provide satisfactory oxidation and subsequent removal of manganese (II)."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["M.S."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vi, 45 pages, 1 unnumbered leaves"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Selected factors affecting oxidation of manganese (II) by ozone"]}]}],"canonical_facts":{"dc:contributor.committeechair":["King, Paul H."],"dc:contributor.committeemember":["Hoehn, Robert C.","Boardman, Gregory D."],"dc:contributor.department":["Sanitary Engineering"],"dc:creator":["Jensen, David Marc"],"dc:date.accessioned":["2026-02-20T22:46:50Z"],"dc:date.available":["2026-02-20T22:46:50Z"],"dc:date.issued":["1979"],"dc:description.abstract":["The series of experiments reported in this research was concerned with the oxidation of manganese (II) by ozone under conditions of variable pH and alkalinity. The experiments were conducted using a bench scale batch reactor to facilitate ozonation followed by filtration. The results of the experiment indicated that for a specified water source, pH and alkalinity within the ranges studied did not measurably affect the rate of oxidation of soluble manganese. The manganese exhibited a tendency to resolubilize upon overdosage with ozone, probably due to formation of the permanganate ion. Drinking water standards for manganese can be effectively met upon subsequent filtration if overdosing of ozone is avoided. The oxidation kinetics were rapid in that a contact period of one minute and an ozone dosage of 1.5 mg/1 were sufficient to provide satisfactory oxidation and subsequent removal of manganese (II)."],"dc:description.degree":["M.S."],"dc:format.extent":["vi, 45 pages, 1 unnumbered leaves"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10919/141419"],"dc:language.iso":["en"],"dc:publisher":["Virginia Polytechnic Institute and State University"],"dc:relation.isformatof":["OCLC# 05524680"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1979.J458"],"dc:subject.lcsh":["Manganese"],"dc:title":["Selected factors affecting oxidation of manganese (II) by ozone"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Sanitary Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["M.S."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:16:14Z"}