{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/142395"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/142395","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Modular Microanalytical Systems for Trace-level Chemical Analysis","abstract":"Airborne organic compounds, such as volatile organic compounds (VOCs) and organic aerosols (OAs), carry rich information about various ecological, environmental, physiological, and manufacturing processes. Growing concerns about environmental conditions and public health have driven the rapid development of analytical tools capable of characterizing trace levels of VOCs and OAs. Among other technologies, gas chromatography (GC) is considered the gold standard for analyzing organic compounds. However, conventional GC systems are expensive, bulky, and power-hungry, and require trained technicians to operate the system, limiting their adoption to a lab setting. Consequently, there is a growing demand for portable analytical systems capable of performing in situ, trace-level chemical analysis. To address this need, microelectromechanical systems (MEMS)-based microanalytical tools and micro gas chromatography (μGC) systems have emerged as powerful, miniaturized platforms for (bio)chemical analysis. They miniaturize the key components of a bench-top GC by implementing microfluidic devices, including a micropreconcentrator (μPC), a microseparation column (μSC), and photoionization detectors (PIDs). These developments drastically reduce sample-reagent volume requirements, accelerate processing times, and enable automation, making them ideal for in-situ applications. Although μGC miniaturizes the functionality of a bench-top GC, effective collection of trace samples and seamless integration of microfluidic components remain challenging. These challenges arise from design constraints, manufacturing complexities, diverse functional requirements, demanding operating conditions, and incompatible maintenance procedures, collectively limit system scalability and widespread adoption. This dissertation addresses these challenges by developing highly modular microanalytical tools for trace-level analysis of gas- and particle-phase organic compounds. Central to this work is a standardized Fluidic and Electrical Modular Interfacing (FEMI) architecture that provides removable, gas-tight, high-temperature-resistant fluidic connections for implementing complex microfluidic systems. Through the development of FEMI and a high-throughput μPC, this work demonstrates a portable μPC-based sample injection system compatible with bench-top GC, detecting VOCs down to 100 parts per trillion (ppt). This work also demonstrates FEMI-GC, a highly modular μGC that integrates μPC, μSC, and PID within a 3.75 L, 2 kg footprint, achieving a 700 ppt detection limit and a dynamic range over 50,000x. This work extends the functionality by developing a CNC-machined impactor and a μGC that successfully collected particles as small as 100 nm, enabling the detection of compounds with boiling points up to 450 ˚C, a first for μGC platforms. Finally, this work introduces the next-generation μGC called SPOCK (Size-filtered Particle Odor Chromatographic Kernel), which combines a CNC-machined cyclone, a CNC-machined impactor, μPC, μSC, and PID to simultaneously analyze VOCs and OAs. This lays the groundwork for a near real-time, highly configurable, fabrication-agnostic μGC platform for trace-level chemical analysis.","abstract_html":"Airborne organic compounds, such as volatile organic compounds (VOCs) and organic aerosols (OAs), carry rich information about various ecological, environmental, physiological, and manufacturing processes. Growing concerns about environmental conditions and public health have driven the rapid development of analytical tools capable of characterizing trace levels of VOCs and OAs. Among other technologies, gas chromatography (GC) is considered the gold standard for analyzing organic compounds. However, conventional GC systems are expensive, bulky, and power-hungry, and require trained technicians to operate the system, limiting their adoption to a lab setting. Consequently, there is a growing demand for portable analytical systems capable of performing in situ, trace-level chemical analysis. To address this need, microelectromechanical systems (MEMS)-based microanalytical tools and micro gas chromatography (μGC) systems have emerged as powerful, miniaturized platforms for (bio)chemical analysis. They miniaturize the key components of a bench-top GC by implementing microfluidic devices, including a micropreconcentrator (μPC), a microseparation column (μSC), and photoionization detectors (PIDs). These developments drastically reduce sample-reagent volume requirements, accelerate processing times, and enable automation, making them ideal for in-situ applications. Although μGC miniaturizes the functionality of a bench-top GC, effective collection of trace samples and seamless integration of microfluidic components remain challenging. These challenges arise from design constraints, manufacturing complexities, diverse functional requirements, demanding operating conditions, and incompatible maintenance procedures, collectively limit system scalability and widespread adoption. This dissertation addresses these challenges by developing highly modular microanalytical tools for trace-level analysis of gas- and particle-phase organic compounds. Central to this work is a standardized Fluidic and Electrical Modular Interfacing (FEMI) architecture that provides removable, gas-tight, high-temperature-resistant fluidic connections for implementing complex microfluidic systems. Through the development of FEMI and a high-throughput μPC, this work demonstrates a portable μPC-based sample injection system compatible with bench-top GC, detecting VOCs down to 100 parts per trillion (ppt). This work also demonstrates FEMI-GC, a highly modular μGC that integrates μPC, μSC, and PID within a 3.75 L, 2 kg footprint, achieving a 700 ppt detection limit and a dynamic range over 50,000x. This work extends the functionality by developing a CNC-machined impactor and a μGC that successfully collected particles as small as 100 nm, enabling the detection of compounds with boiling points up to 450 ˚C, a first for μGC platforms. Finally, this work introduces the next-generation μGC called SPOCK (Size-filtered Particle Odor Chromatographic Kernel), which combines a CNC-machined cyclone, a CNC-machined impactor, μPC, μSC, and PID to simultaneously analyze VOCs and OAs. This lays the groundwork for a near real-time, highly configurable, fabrication-agnostic μGC platform for trace-level chemical analysis.","abstract_has_math":false,"creators":["Thamatam, Nipun"],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Agah, Masoud"],"committee_members":["Jia, Xiaoting","Marr, Linsey C.","Dimarino, Christina Marie","Hudait, Mantu K."],"year":2026,"date_issued":"2026-03-20","date_published":"2026-03-20","updated_at":"2026-11-18T20:17:56Z","subjects":["Microelectromechanical systems","Micro total analytical systems","Micro gas chromatography","Volatile organic compounds","Trace analysis","Micropreconcentrator"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:45744"],"render_values":[{"text":"vt_gsexam:45744","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/142395","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/142395","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F142395","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Agah, Masoud"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Jia, Xiaoting","Marr, Linsey C.","Dimarino, Christina Marie","Hudait, Mantu K."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Thamatam, Nipun"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-21T08:00:13Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-03-21T08:00:13Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-03-20"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Microelectromechanical systems","Micro total analytical systems","Micro gas chromatography","Volatile organic compounds","Trace analysis","Micropreconcentrator"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:45744"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/142395"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Airborne organic compounds, such as volatile organic compounds (VOCs) and organic aerosols (OAs), carry rich information about various ecological, environmental, physiological, and manufacturing processes. Growing concerns about environmental conditions and public health have driven the rapid development of analytical tools capable of characterizing trace levels of VOCs and OAs. Among other technologies, gas chromatography (GC) is considered the gold standard for analyzing organic compounds. However, conventional GC systems are expensive, bulky, and power-hungry, and require trained technicians to operate the system, limiting their adoption to a lab setting. Consequently, there is a growing demand for portable analytical systems capable of performing in situ, trace-level chemical analysis. To address this need, microelectromechanical systems (MEMS)-based microanalytical tools and micro gas chromatography (μGC) systems have emerged as powerful, miniaturized platforms for (bio)chemical analysis. They miniaturize the key components of a bench-top GC by implementing microfluidic devices, including a micropreconcentrator (μPC), a microseparation column (μSC), and photoionization detectors (PIDs). These developments drastically reduce sample-reagent volume requirements, accelerate processing times, and enable automation, making them ideal for in-situ applications. Although μGC miniaturizes the functionality of a bench-top GC, effective collection of trace samples and seamless integration of microfluidic components remain challenging. These challenges arise from design constraints, manufacturing complexities, diverse functional requirements, demanding operating conditions, and incompatible maintenance procedures, collectively limit system scalability and widespread adoption. This dissertation addresses these challenges by developing highly modular microanalytical tools for trace-level analysis of gas- and particle-phase organic compounds. Central to this work is a standardized Fluidic and Electrical Modular Interfacing (FEMI) architecture that provides removable, gas-tight, high-temperature-resistant fluidic connections for implementing complex microfluidic systems. Through the development of FEMI and a high-throughput μPC, this work demonstrates a portable μPC-based sample injection system compatible with bench-top GC, detecting VOCs down to 100 parts per trillion (ppt). This work also demonstrates FEMI-GC, a highly modular μGC that integrates μPC, μSC, and PID within a 3.75 L, 2 kg footprint, achieving a 700 ppt detection limit and a dynamic range over 50,000x. This work extends the functionality by developing a CNC-machined impactor and a μGC that successfully collected particles as small as 100 nm, enabling the detection of compounds with boiling points up to 450 ˚C, a first for μGC platforms. Finally, this work introduces the next-generation μGC called SPOCK (Size-filtered Particle Odor Chromatographic Kernel), which combines a CNC-machined cyclone, a CNC-machined impactor, μPC, μSC, and PID to simultaneously analyze VOCs and OAs. This lays the groundwork for a near real-time, highly configurable, fabrication-agnostic μGC platform for trace-level chemical analysis."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Airborne organic compounds, including gases and suspended particles, carry important information about our environment, health, and industrial processes. Monitoring these compounds is critical for understanding air quality, detecting pollution, and studying physiological processes. Traditional laboratory instruments, such as gas chromatography systems, are powerful but bulky, expensive, and require trained technicians, limiting their use outside centralized facilities. These factors create a clear need for portable systems capable of analyzing samples on-site. This dissertation addresses the need by developing microelectromechanical systems (MEMS)-based micro gas chromatography (μGC) systems. A central innovation is a modular system architecture that seamlessly integrates micro-scale and macro-scale devices for reliable operation while ensuring high performance. Using this approach, along with device-level development, a portable MEMS-based sample-collection system and a MEMS-based μGC system were developed, both capable of detecting extremely low levels of gas-phase organic compounds at parts-per-trillion levels. The functionality of this system was further extended by incorporating a particle collector to analyze organic particles ranging from 100 nm to a few micrometers in diameter, a first in μGC platforms. This work also introduces a next-generation μGC system that combines several miniature devices into a single platform to simultaneously analyze gas- and particle-phase organic compounds. This research lays the groundwork for real-time, on-site chemical analysis that could transform how we study and respond to airborne organic compounds in environmental and health monitoring applications."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Modular Microanalytical Systems for Trace-level Chemical Analysis"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Agah, Masoud"],"dc:contributor.committeemember":["Jia, Xiaoting","Marr, Linsey C.","Dimarino, Christina Marie","Hudait, Mantu K."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Thamatam, Nipun"],"dc:date.accessioned":["2026-03-21T08:00:13Z"],"dc:date.available":["2026-03-21T08:00:13Z"],"dc:date.issued":["2026-03-20"],"dc:description.abstract":["Airborne organic compounds, such as volatile organic compounds (VOCs) and organic aerosols (OAs), carry rich information about various ecological, environmental, physiological, and manufacturing processes. Growing concerns about environmental conditions and public health have driven the rapid development of analytical tools capable of characterizing trace levels of VOCs and OAs. Among other technologies, gas chromatography (GC) is considered the gold standard for analyzing organic compounds. However, conventional GC systems are expensive, bulky, and power-hungry, and require trained technicians to operate the system, limiting their adoption to a lab setting. Consequently, there is a growing demand for portable analytical systems capable of performing in situ, trace-level chemical analysis. To address this need, microelectromechanical systems (MEMS)-based microanalytical tools and micro gas chromatography (μGC) systems have emerged as powerful, miniaturized platforms for (bio)chemical analysis. They miniaturize the key components of a bench-top GC by implementing microfluidic devices, including a micropreconcentrator (μPC), a microseparation column (μSC), and photoionization detectors (PIDs). These developments drastically reduce sample-reagent volume requirements, accelerate processing times, and enable automation, making them ideal for in-situ applications. Although μGC miniaturizes the functionality of a bench-top GC, effective collection of trace samples and seamless integration of microfluidic components remain challenging. These challenges arise from design constraints, manufacturing complexities, diverse functional requirements, demanding operating conditions, and incompatible maintenance procedures, collectively limit system scalability and widespread adoption. This dissertation addresses these challenges by developing highly modular microanalytical tools for trace-level analysis of gas- and particle-phase organic compounds. Central to this work is a standardized Fluidic and Electrical Modular Interfacing (FEMI) architecture that provides removable, gas-tight, high-temperature-resistant fluidic connections for implementing complex microfluidic systems. Through the development of FEMI and a high-throughput μPC, this work demonstrates a portable μPC-based sample injection system compatible with bench-top GC, detecting VOCs down to 100 parts per trillion (ppt). This work also demonstrates FEMI-GC, a highly modular μGC that integrates μPC, μSC, and PID within a 3.75 L, 2 kg footprint, achieving a 700 ppt detection limit and a dynamic range over 50,000x. This work extends the functionality by developing a CNC-machined impactor and a μGC that successfully collected particles as small as 100 nm, enabling the detection of compounds with boiling points up to 450 ˚C, a first for μGC platforms. Finally, this work introduces the next-generation μGC called SPOCK (Size-filtered Particle Odor Chromatographic Kernel), which combines a CNC-machined cyclone, a CNC-machined impactor, μPC, μSC, and PID to simultaneously analyze VOCs and OAs. This lays the groundwork for a near real-time, highly configurable, fabrication-agnostic μGC platform for trace-level chemical analysis."],"dc:description.abstractgeneral":["Airborne organic compounds, including gases and suspended particles, carry important information about our environment, health, and industrial processes. Monitoring these compounds is critical for understanding air quality, detecting pollution, and studying physiological processes. Traditional laboratory instruments, such as gas chromatography systems, are powerful but bulky, expensive, and require trained technicians, limiting their use outside centralized facilities. These factors create a clear need for portable systems capable of analyzing samples on-site. This dissertation addresses the need by developing microelectromechanical systems (MEMS)-based micro gas chromatography (μGC) systems. A central innovation is a modular system architecture that seamlessly integrates micro-scale and macro-scale devices for reliable operation while ensuring high performance. Using this approach, along with device-level development, a portable MEMS-based sample-collection system and a MEMS-based μGC system were developed, both capable of detecting extremely low levels of gas-phase organic compounds at parts-per-trillion levels. The functionality of this system was further extended by incorporating a particle collector to analyze organic particles ranging from 100 nm to a few micrometers in diameter, a first in μGC platforms. This work also introduces a next-generation μGC system that combines several miniature devices into a single platform to simultaneously analyze gas- and particle-phase organic compounds. This research lays the groundwork for real-time, on-site chemical analysis that could transform how we study and respond to airborne organic compounds in environmental and health monitoring applications."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:45744"],"dc:identifier.uri":["https://hdl.handle.net/10919/142395"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Microelectromechanical systems","Micro total analytical systems","Micro gas chromatography","Volatile organic compounds","Trace analysis","Micropreconcentrator"],"dc:title":["Modular Microanalytical Systems for Trace-level Chemical Analysis"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:17:56Z"}