{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/142397"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/142397","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Exploring The Realm of Legionella in Water Heaters: Hormetic Copper, Antagonistic Neochlamydia, Holistic Insulation and Protective Sediment","abstract":"Opportunistic premise plumbing pathogens (OPPPs), including Legionella pneumophila and Mycobacterium avium, are increasingly associated with waterborne disease outbreaks in the United States. Despite their rising prominence, several factors influencing the growth and mitigation of Legionella and other OPPPs, such as pipe materials, microbial ecology, temperature gradients, water heater configuration, and the role of sediment are poorly understood. This dissertation sheds light on the role of these factors using complementary microcosm and pilot-scale experiments to examine effects of various control strategies on OPPP growth. Chapter 2 investigates how copper (0–2000 µg/L) impacted L. pneumophila and M. avium over an 11-month period using microcosms to simulate warm premise plumbing conditions. Copper was confirmed to have a hormetic effect, acting as a nutrient at low levels and an antimicrobial at high levels. At an intermediate copper dose of 250 μg/L, M. avium and total cell counts peaked in concentration, whereas the impact of copper on L. pneumophila at this dosage was stochastic amongst replicates. Comparatively, 2000 μg/L of copper suppressed M. avium, L. pneumophila, and total cell counts, though total cell counts steadily rebounded at this dosage throughout the entire experiment Chapter 3 closely examined the stochastic behavior of L. pneumophila in microcosms. A retrospective analysis on the copper-dosed microcosms described above and an earlier study of conditions leading to the Flint Water Crisis Legionnaires' Disease outbreak reveals a potential antagonistic relationship between Neochlamydia and L. pneumophila. This is consistent with prior evidence from pure culture studies that amoebae harboring Neochlamydia are resistant to L. pneumophila infection. The background water chemistry and pipe materials can influence the outcome of the competition between Neochlamydia and Legionella, suggesting probiotic approaches for OPPP control are already naturally occurring in some buildings. Two chapters of the dissertation focus on full scale experiments in residential water heaters. In chapter 4 recirculating, standard, and on-demand (tankless) water heater configurations were operated and evaluated for delivered hot-water temperatures, internal thermal profiles, energy efficiency, and volumes of water within temperature ranges at risk for Legionella growth. At a setpoint of 48°C, the recirculating configuration had the lowest energy efficiency and the highest volume of water at risk for Legionella growth, whereas at 66° C the standard tank had highest growth risk. Adding extra insulation to standard electric water heaters could eliminate Legionella growth habitat while reducing heat loss--a holistic approach to improving environmental sustainability and public health. Although thermal control is widely recommended for Legionella mitigation, chapter 5 reveals important limitations to the approach. Experiments using a typical 40-gallon residential water heater demonstrated that sediment, which can naturally accumulate at the bottom of water heater tanks, created dead space with temperatures that cooled with sediment depth. Even when the bulk water in the tank was completely mixed and the bulk water temperatures were ≥55–60 °C, portions of the sediment were cooler and permissive for Legionella growth. Two distinct mechanisms were responsible for cooling the sediment and its associated dead space: contact of the bottom of the tank with a relatively cold floor and settling of cold influent water. The sediment also increased the available surface area by several orders of magnitude compared to the internal surface area of the water heater. The cooler temperatures and high surface area could create extraordinary pathogen growth potential that causes culturable and molecularly detectable L. pneumophila to persist indefinitely. Use of external insulation between the tank and the floor can sometimes heat the sediment to a point that could eliminate Legionella growth. Chapter 6 is a Viewpoint that examines the interplay of truth, trust, and utility practices in pre-venting waterborne disease outbreaks by shaping water quality before it enters buildings to re-duce Legionnaires' Disease risk. For instance, infrastructure upgrades and improved treatment can increase disinfectant residuals and reduce sediment in supply waters, honoring a utilities to the social contract with their customers. We argue that continued denial and deception associated with this responsibility will lead to distrust and disinvestment, similar to that which arose from past failures to deal with health treats from lead contamination due to corrosive water. The overall dissertation illustrates how OPPP and L. pneumophila control in premise plumbing is influenced by ecological and engineering factors, including water chemistry, microbial inter-actions, temperature gradients, sediment and water heater design. These novel findings help explain why previously recommended mitigation strategies may not always suppress L. pneumophila in buildings and highlight the need for holistic control approaches targeting worst case niches in which Legionella can thrive.","abstract_html":"Opportunistic premise plumbing pathogens (OPPPs), including Legionella pneumophila and Mycobacterium avium, are increasingly associated with waterborne disease outbreaks in the United States. Despite their rising prominence, several factors influencing the growth and mitigation of Legionella and other OPPPs, such as pipe materials, microbial ecology, temperature gradients, water heater configuration, and the role of sediment are poorly understood. This dissertation sheds light on the role of these factors using complementary microcosm and pilot-scale experiments to examine effects of various control strategies on OPPP growth. Chapter 2 investigates how copper (0–2000 µg/L) impacted L. pneumophila and M. avium over an 11-month period using microcosms to simulate warm premise plumbing conditions. Copper was confirmed to have a hormetic effect, acting as a nutrient at low levels and an antimicrobial at high levels. At an intermediate copper dose of 250 μg/L, M. avium and total cell counts peaked in concentration, whereas the impact of copper on L. pneumophila at this dosage was stochastic amongst replicates. Comparatively, 2000 μg/L of copper suppressed M. avium, L. pneumophila, and total cell counts, though total cell counts steadily rebounded at this dosage throughout the entire experiment Chapter 3 closely examined the stochastic behavior of L. pneumophila in microcosms. A retrospective analysis on the copper-dosed microcosms described above and an earlier study of conditions leading to the Flint Water Crisis Legionnaires&#x27; Disease outbreak reveals a potential antagonistic relationship between Neochlamydia and L. pneumophila. This is consistent with prior evidence from pure culture studies that amoebae harboring Neochlamydia are resistant to L. pneumophila infection. The background water chemistry and pipe materials can influence the outcome of the competition between Neochlamydia and Legionella, suggesting probiotic approaches for OPPP control are already naturally occurring in some buildings. Two chapters of the dissertation focus on full scale experiments in residential water heaters. In chapter 4 recirculating, standard, and on-demand (tankless) water heater configurations were operated and evaluated for delivered hot-water temperatures, internal thermal profiles, energy efficiency, and volumes of water within temperature ranges at risk for Legionella growth. At a setpoint of 48°C, the recirculating configuration had the lowest energy efficiency and the highest volume of water at risk for Legionella growth, whereas at 66° C the standard tank had highest growth risk. Adding extra insulation to standard electric water heaters could eliminate Legionella growth habitat while reducing heat loss--a holistic approach to improving environmental sustainability and public health. Although thermal control is widely recommended for Legionella mitigation, chapter 5 reveals important limitations to the approach. Experiments using a typical 40-gallon residential water heater demonstrated that sediment, which can naturally accumulate at the bottom of water heater tanks, created dead space with temperatures that cooled with sediment depth. Even when the bulk water in the tank was completely mixed and the bulk water temperatures were ≥55–60 °C, portions of the sediment were cooler and permissive for Legionella growth. Two distinct mechanisms were responsible for cooling the sediment and its associated dead space: contact of the bottom of the tank with a relatively cold floor and settling of cold influent water. The sediment also increased the available surface area by several orders of magnitude compared to the internal surface area of the water heater. The cooler temperatures and high surface area could create extraordinary pathogen growth potential that causes culturable and molecularly detectable L. pneumophila to persist indefinitely. Use of external insulation between the tank and the floor can sometimes heat the sediment to a point that could eliminate Legionella growth. Chapter 6 is a Viewpoint that examines the interplay of truth, trust, and utility practices in pre-venting waterborne disease outbreaks by shaping water quality before it enters buildings to re-duce Legionnaires&#x27; Disease risk. For instance, infrastructure upgrades and improved treatment can increase disinfectant residuals and reduce sediment in supply waters, honoring a utilities to the social contract with their customers. We argue that continued denial and deception associated with this responsibility will lead to distrust and disinvestment, similar to that which arose from past failures to deal with health treats from lead contamination due to corrosive water. The overall dissertation illustrates how OPPP and L. pneumophila control in premise plumbing is influenced by ecological and engineering factors, including water chemistry, microbial inter-actions, temperature gradients, sediment and water heater design. These novel findings help explain why previously recommended mitigation strategies may not always suppress L. pneumophila in buildings and highlight the need for holistic control approaches targeting worst case niches in which Legionella can thrive.","abstract_has_math":false,"creators":["Roman Jr, Fernando Adali"],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Civil Engineering","degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Edwards, Marc A."],"committee_members":["Vikesland, Peter J.","Pruden-Bagchi, Amy Jill","Falkinham, Joseph O."],"year":2026,"date_issued":"2026-03-20","date_published":"2026-03-20","updated_at":"2026-11-18T20:01:23Z","subjects":["Legionella pneumophila","Opportunistic Pathogens","Premise Plumbing","Water Heaters","Insulation","Temperature","Drinking Water","Copper","Neochlamydia","Microbial Ecology"],"languages":["en"],"rights":["Creative Commons Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:45793"],"render_values":[{"text":"vt_gsexam:45793","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/142397","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/142397","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F142397","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Edwards, Marc A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Vikesland, Peter J.","Pruden-Bagchi, Amy Jill","Falkinham, Joseph O."]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Roman Jr, Fernando Adali"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-03-21T08:00:25Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-03-21T08:00:25Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-03-20"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Legionella pneumophila","Opportunistic Pathogens","Premise Plumbing","Water Heaters","Insulation","Temperature","Drinking Water","Copper","Neochlamydia","Microbial Ecology"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Creative Commons Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:45793"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/142397"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Opportunistic premise plumbing pathogens (OPPPs), including Legionella pneumophila and Mycobacterium avium, are increasingly associated with waterborne disease outbreaks in the United States. Despite their rising prominence, several factors influencing the growth and mitigation of Legionella and other OPPPs, such as pipe materials, microbial ecology, temperature gradients, water heater configuration, and the role of sediment are poorly understood. This dissertation sheds light on the role of these factors using complementary microcosm and pilot-scale experiments to examine effects of various control strategies on OPPP growth. Chapter 2 investigates how copper (0–2000 µg/L) impacted L. pneumophila and M. avium over an 11-month period using microcosms to simulate warm premise plumbing conditions. Copper was confirmed to have a hormetic effect, acting as a nutrient at low levels and an antimicrobial at high levels. At an intermediate copper dose of 250 μg/L, M. avium and total cell counts peaked in concentration, whereas the impact of copper on L. pneumophila at this dosage was stochastic amongst replicates. Comparatively, 2000 μg/L of copper suppressed M. avium, L. pneumophila, and total cell counts, though total cell counts steadily rebounded at this dosage throughout the entire experiment Chapter 3 closely examined the stochastic behavior of L. pneumophila in microcosms. A retrospective analysis on the copper-dosed microcosms described above and an earlier study of conditions leading to the Flint Water Crisis Legionnaires' Disease outbreak reveals a potential antagonistic relationship between Neochlamydia and L. pneumophila. This is consistent with prior evidence from pure culture studies that amoebae harboring Neochlamydia are resistant to L. pneumophila infection. The background water chemistry and pipe materials can influence the outcome of the competition between Neochlamydia and Legionella, suggesting probiotic approaches for OPPP control are already naturally occurring in some buildings. Two chapters of the dissertation focus on full scale experiments in residential water heaters. In chapter 4 recirculating, standard, and on-demand (tankless) water heater configurations were operated and evaluated for delivered hot-water temperatures, internal thermal profiles, energy efficiency, and volumes of water within temperature ranges at risk for Legionella growth. At a setpoint of 48°C, the recirculating configuration had the lowest energy efficiency and the highest volume of water at risk for Legionella growth, whereas at 66° C the standard tank had highest growth risk. Adding extra insulation to standard electric water heaters could eliminate Legionella growth habitat while reducing heat loss--a holistic approach to improving environmental sustainability and public health. Although thermal control is widely recommended for Legionella mitigation, chapter 5 reveals important limitations to the approach. Experiments using a typical 40-gallon residential water heater demonstrated that sediment, which can naturally accumulate at the bottom of water heater tanks, created dead space with temperatures that cooled with sediment depth. Even when the bulk water in the tank was completely mixed and the bulk water temperatures were ≥55–60 °C, portions of the sediment were cooler and permissive for Legionella growth. Two distinct mechanisms were responsible for cooling the sediment and its associated dead space: contact of the bottom of the tank with a relatively cold floor and settling of cold influent water. The sediment also increased the available surface area by several orders of magnitude compared to the internal surface area of the water heater. The cooler temperatures and high surface area could create extraordinary pathogen growth potential that causes culturable and molecularly detectable L. pneumophila to persist indefinitely. Use of external insulation between the tank and the floor can sometimes heat the sediment to a point that could eliminate Legionella growth. Chapter 6 is a Viewpoint that examines the interplay of truth, trust, and utility practices in pre-venting waterborne disease outbreaks by shaping water quality before it enters buildings to re-duce Legionnaires' Disease risk. For instance, infrastructure upgrades and improved treatment can increase disinfectant residuals and reduce sediment in supply waters, honoring a utilities to the social contract with their customers. We argue that continued denial and deception associated with this responsibility will lead to distrust and disinvestment, similar to that which arose from past failures to deal with health treats from lead contamination due to corrosive water. The overall dissertation illustrates how OPPP and L. pneumophila control in premise plumbing is influenced by ecological and engineering factors, including water chemistry, microbial inter-actions, temperature gradients, sediment and water heater design. These novel findings help explain why previously recommended mitigation strategies may not always suppress L. pneumophila in buildings and highlight the need for holistic control approaches targeting worst case niches in which Legionella can thrive."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Legionnaires' Disease is a respiratory infection caused by bacteria called Legionella. Given the right conditions, Legionella will sometimes grow in pipes delivering tap water inside buildings and homes. Other pathogens, such as Mycobacterium avium, also grow in building plumbing systems and pose risks to human health. These organisms are collectively referred to as opportunistic premise plumbing pathogens (OPPPs). This dissertation investigates ongoing challenges and uncertainties related to controlling Legionella and other OPPPs in premise plumbing settings. Small-scale microcosms and laboratory plumbing systems were used to recreate conditions happening in real-world building plumbing and test how copper, water chemistry, pipe material, and interactions between microorganisms can encourage or suppress Legionella growth. Additionally, full-scale residential water heaters examined how the type of water heater, recirculating pumps, temperature settings, cold floors, extra insulation, and the buildup of sediment can influence Legionella growth. The results showed that copper could act as a nutrient at low concentrations but had antimicrobial effects at higher doses. At an intermediate dose of 250 μg/L, growth was highest for Myco-bacterium avium and cell counts, but results varied for Legionella amongst replicates. This re-search also found evidence that other bacteria, such as Neochlamydia, might compete with Legionella in drinking water systems, opening the door for future potential probiotic approaches and a better understanding of the factors that affect whether Legionella will grow in a given drinking water system. In the water heater experiments, certain water heater designs and operating conditions created lukewarm zones at the bottom of tanks where Legionella could thrive, even when water at the top portion of the tank was adjusted to a temperature that effectively kills the bacteria. Sediment that naturally accumulates at the bottom of heaters also provided a realm for thriving Legionella, in terms of the lukewarm temperatures it prefers and surface area for its attachment and growth. In some cases, adding insulation to water heaters increased temperatures in both the bulk water and sediment to the point where Legionella should not grow, while also helping save energy through reduced heat loss. Since insulation may provide multiple benefits, and can pay for itself by reducing energy costs, it could be a simple and cost-effective game changer to reduce Legionella risk. This work also looks beyond premise plumbing to show how decisions and assigned responsibilities, by water utilities and regulators, can shape water quality before it enters buildings and influence the risk of Legionella growth in water heaters. Denial of responsibility for Legionella control may contribute to public distrust and disinvestment in water infrastructure, as was the case for analogous historical failures in managing lead contamination due to corrosive water. Overall, the dissertation helps explain why different buildings can experience different out-comes when using recommended thermal inactivation strategies to control Legionella, even when it comes to seemingly identical homes in the same neighborhood or branches of plumbing in the same building. It demonstrates how multiple interacting factors, including chemistry, microbial ecology, temperature gradients, sediment, and water heater system configurations, can create localized conditions where thermal and chemical inactivation are not always effective. Ultimately, the dissertation supports actions that can be taken by consumers, plumbers, and water utilities, in a shared responsibility approach, to reduce Legionella risk and protect public health."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Exploring The Realm of Legionella in Water Heaters: Hormetic Copper, Antagonistic Neochlamydia, Holistic Insulation and Protective Sediment"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Edwards, Marc A."],"dc:contributor.committeemember":["Vikesland, Peter J.","Pruden-Bagchi, Amy Jill","Falkinham, Joseph O."],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:creator":["Roman Jr, Fernando Adali"],"dc:date.accessioned":["2026-03-21T08:00:25Z"],"dc:date.available":["2026-03-21T08:00:25Z"],"dc:date.issued":["2026-03-20"],"dc:description.abstract":["Opportunistic premise plumbing pathogens (OPPPs), including Legionella pneumophila and Mycobacterium avium, are increasingly associated with waterborne disease outbreaks in the United States. Despite their rising prominence, several factors influencing the growth and mitigation of Legionella and other OPPPs, such as pipe materials, microbial ecology, temperature gradients, water heater configuration, and the role of sediment are poorly understood. This dissertation sheds light on the role of these factors using complementary microcosm and pilot-scale experiments to examine effects of various control strategies on OPPP growth. Chapter 2 investigates how copper (0–2000 µg/L) impacted L. pneumophila and M. avium over an 11-month period using microcosms to simulate warm premise plumbing conditions. Copper was confirmed to have a hormetic effect, acting as a nutrient at low levels and an antimicrobial at high levels. At an intermediate copper dose of 250 μg/L, M. avium and total cell counts peaked in concentration, whereas the impact of copper on L. pneumophila at this dosage was stochastic amongst replicates. Comparatively, 2000 μg/L of copper suppressed M. avium, L. pneumophila, and total cell counts, though total cell counts steadily rebounded at this dosage throughout the entire experiment Chapter 3 closely examined the stochastic behavior of L. pneumophila in microcosms. A retrospective analysis on the copper-dosed microcosms described above and an earlier study of conditions leading to the Flint Water Crisis Legionnaires' Disease outbreak reveals a potential antagonistic relationship between Neochlamydia and L. pneumophila. This is consistent with prior evidence from pure culture studies that amoebae harboring Neochlamydia are resistant to L. pneumophila infection. The background water chemistry and pipe materials can influence the outcome of the competition between Neochlamydia and Legionella, suggesting probiotic approaches for OPPP control are already naturally occurring in some buildings. Two chapters of the dissertation focus on full scale experiments in residential water heaters. In chapter 4 recirculating, standard, and on-demand (tankless) water heater configurations were operated and evaluated for delivered hot-water temperatures, internal thermal profiles, energy efficiency, and volumes of water within temperature ranges at risk for Legionella growth. At a setpoint of 48°C, the recirculating configuration had the lowest energy efficiency and the highest volume of water at risk for Legionella growth, whereas at 66° C the standard tank had highest growth risk. Adding extra insulation to standard electric water heaters could eliminate Legionella growth habitat while reducing heat loss--a holistic approach to improving environmental sustainability and public health. Although thermal control is widely recommended for Legionella mitigation, chapter 5 reveals important limitations to the approach. Experiments using a typical 40-gallon residential water heater demonstrated that sediment, which can naturally accumulate at the bottom of water heater tanks, created dead space with temperatures that cooled with sediment depth. Even when the bulk water in the tank was completely mixed and the bulk water temperatures were ≥55–60 °C, portions of the sediment were cooler and permissive for Legionella growth. Two distinct mechanisms were responsible for cooling the sediment and its associated dead space: contact of the bottom of the tank with a relatively cold floor and settling of cold influent water. The sediment also increased the available surface area by several orders of magnitude compared to the internal surface area of the water heater. The cooler temperatures and high surface area could create extraordinary pathogen growth potential that causes culturable and molecularly detectable L. pneumophila to persist indefinitely. Use of external insulation between the tank and the floor can sometimes heat the sediment to a point that could eliminate Legionella growth. Chapter 6 is a Viewpoint that examines the interplay of truth, trust, and utility practices in pre-venting waterborne disease outbreaks by shaping water quality before it enters buildings to re-duce Legionnaires' Disease risk. For instance, infrastructure upgrades and improved treatment can increase disinfectant residuals and reduce sediment in supply waters, honoring a utilities to the social contract with their customers. We argue that continued denial and deception associated with this responsibility will lead to distrust and disinvestment, similar to that which arose from past failures to deal with health treats from lead contamination due to corrosive water. The overall dissertation illustrates how OPPP and L. pneumophila control in premise plumbing is influenced by ecological and engineering factors, including water chemistry, microbial inter-actions, temperature gradients, sediment and water heater design. These novel findings help explain why previously recommended mitigation strategies may not always suppress L. pneumophila in buildings and highlight the need for holistic control approaches targeting worst case niches in which Legionella can thrive."],"dc:description.abstractgeneral":["Legionnaires' Disease is a respiratory infection caused by bacteria called Legionella. Given the right conditions, Legionella will sometimes grow in pipes delivering tap water inside buildings and homes. Other pathogens, such as Mycobacterium avium, also grow in building plumbing systems and pose risks to human health. These organisms are collectively referred to as opportunistic premise plumbing pathogens (OPPPs). This dissertation investigates ongoing challenges and uncertainties related to controlling Legionella and other OPPPs in premise plumbing settings. Small-scale microcosms and laboratory plumbing systems were used to recreate conditions happening in real-world building plumbing and test how copper, water chemistry, pipe material, and interactions between microorganisms can encourage or suppress Legionella growth. Additionally, full-scale residential water heaters examined how the type of water heater, recirculating pumps, temperature settings, cold floors, extra insulation, and the buildup of sediment can influence Legionella growth. The results showed that copper could act as a nutrient at low concentrations but had antimicrobial effects at higher doses. At an intermediate dose of 250 μg/L, growth was highest for Myco-bacterium avium and cell counts, but results varied for Legionella amongst replicates. This re-search also found evidence that other bacteria, such as Neochlamydia, might compete with Legionella in drinking water systems, opening the door for future potential probiotic approaches and a better understanding of the factors that affect whether Legionella will grow in a given drinking water system. In the water heater experiments, certain water heater designs and operating conditions created lukewarm zones at the bottom of tanks where Legionella could thrive, even when water at the top portion of the tank was adjusted to a temperature that effectively kills the bacteria. Sediment that naturally accumulates at the bottom of heaters also provided a realm for thriving Legionella, in terms of the lukewarm temperatures it prefers and surface area for its attachment and growth. In some cases, adding insulation to water heaters increased temperatures in both the bulk water and sediment to the point where Legionella should not grow, while also helping save energy through reduced heat loss. Since insulation may provide multiple benefits, and can pay for itself by reducing energy costs, it could be a simple and cost-effective game changer to reduce Legionella risk. This work also looks beyond premise plumbing to show how decisions and assigned responsibilities, by water utilities and regulators, can shape water quality before it enters buildings and influence the risk of Legionella growth in water heaters. Denial of responsibility for Legionella control may contribute to public distrust and disinvestment in water infrastructure, as was the case for analogous historical failures in managing lead contamination due to corrosive water. Overall, the dissertation helps explain why different buildings can experience different out-comes when using recommended thermal inactivation strategies to control Legionella, even when it comes to seemingly identical homes in the same neighborhood or branches of plumbing in the same building. It demonstrates how multiple interacting factors, including chemistry, microbial ecology, temperature gradients, sediment, and water heater system configurations, can create localized conditions where thermal and chemical inactivation are not always effective. Ultimately, the dissertation supports actions that can be taken by consumers, plumbers, and water utilities, in a shared responsibility approach, to reduce Legionella risk and protect public health."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:45793"],"dc:identifier.uri":["https://hdl.handle.net/10919/142397"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["Creative Commons Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["Legionella pneumophila","Opportunistic Pathogens","Premise Plumbing","Water Heaters","Insulation","Temperature","Drinking Water","Copper","Neochlamydia","Microbial Ecology"],"dc:title":["Exploring The Realm of Legionella in Water Heaters: Hormetic Copper, Antagonistic Neochlamydia, Holistic Insulation and Protective Sediment"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:01:23Z"}