{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143132"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143132","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Engineering Plasmonic Transducer Arrays for Cyber-Physical-Biological Systems: From Nanoimprinted Bio-Interfaces to Electro-Optical Nanocavities","abstract":"This dissertation investigates and engineers the light–matter interactions of metal–insulator–metal (MIM) nanolaminate nanocavities to realize broadband hybrid electro-optical transducer arrays for cyber-physical-biological systems (CPBS). The vertically stacked MIM architecture supports two spatially overlapping magnetoelectric resonances whose spectral positions and optical cross-sections are tunable through the metal-to-insulator thickness ratio at a fixed device footprint, a capability unique among plasmonic nanostructure geometries that enables engineering of the local density of optical states across the visible to near-infrared without enlarging the transducers footprint. In addition to this electromagnetic foundation, new nanoimprint lithography strategies are developed to pattern MIM nanocavity arrays onto biocompatible substrates including flexible polymer meshes and three-dimensional micropillar architectures, achieving SERS enhancement factors exceeding 10^7 with high spatial uniformity. Deliberate geometric symmetry breaking via oblique thin-film deposition simultaneously activates multiple nonlinear optical channels, including second-harmonic generation, third-harmonic generation, and upconverted photoluminescence, from the same nanostructure across a broad near-infrared excitation range, while anti-correlated interfacial sensitivity between coherent and incoherent channels provides a self-referencing detection modality without exogenous labels. Integration of electrical functionality through a co-design framework, that is in which the same oblique deposition step that activates dark plasmonic modes also forms the vertical electrical interconnect, yields nano-optoelectrode arrays capable of recording synchronized cardiomyocyte action potentials alongside optical transduction. In the electrochemical domain, correlated linear Raman signals resolve transient reaction intermediates invisible to electrical measurement alone, while applied voltage simultaneously and independently modulates second-harmonic generation through Fermi-level shifts at the metal–electrolyte interface and upconverted photoluminescence through hot-carrier interband dynamics, demonstrating mechanistically orthogonal optical readout of interfacial electronic structure. Together, these platforms establish MIM nanolaminate nanocavities as unified transducer building blocks for next-generation CPBS biointerfaces spanning neural recording, organoid integration, and all-optical voltage sensing.","abstract_html":"This dissertation investigates and engineers the light–matter interactions of metal–insulator–metal (MIM) nanolaminate nanocavities to realize broadband hybrid electro-optical transducer arrays for cyber-physical-biological systems (CPBS). The vertically stacked MIM architecture supports two spatially overlapping magnetoelectric resonances whose spectral positions and optical cross-sections are tunable through the metal-to-insulator thickness ratio at a fixed device footprint, a capability unique among plasmonic nanostructure geometries that enables engineering of the local density of optical states across the visible to near-infrared without enlarging the transducers footprint. In addition to this electromagnetic foundation, new nanoimprint lithography strategies are developed to pattern MIM nanocavity arrays onto biocompatible substrates including flexible polymer meshes and three-dimensional micropillar architectures, achieving SERS enhancement factors exceeding 10^7 with high spatial uniformity. Deliberate geometric symmetry breaking via oblique thin-film deposition simultaneously activates multiple nonlinear optical channels, including second-harmonic generation, third-harmonic generation, and upconverted photoluminescence, from the same nanostructure across a broad near-infrared excitation range, while anti-correlated interfacial sensitivity between coherent and incoherent channels provides a self-referencing detection modality without exogenous labels. Integration of electrical functionality through a co-design framework, that is in which the same oblique deposition step that activates dark plasmonic modes also forms the vertical electrical interconnect, yields nano-optoelectrode arrays capable of recording synchronized cardiomyocyte action potentials alongside optical transduction. In the electrochemical domain, correlated linear Raman signals resolve transient reaction intermediates invisible to electrical measurement alone, while applied voltage simultaneously and independently modulates second-harmonic generation through Fermi-level shifts at the metal–electrolyte interface and upconverted photoluminescence through hot-carrier interband dynamics, demonstrating mechanistically orthogonal optical readout of interfacial electronic structure. Together, these platforms establish MIM nanolaminate nanocavities as unified transducer building blocks for next-generation CPBS biointerfaces spanning neural recording, organoid integration, and all-optical voltage sensing.","abstract_has_math":false,"creators":["Mejia, Elieser A."],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Zhou, Wei"],"committee_members":["Jia, Xiaoting","Buehrer, R. Michael","Tian, Zhenhua","Lin, Zin"],"year":2026,"date_issued":"2026-05-21","date_published":"2026-05-21","updated_at":"2026-11-18T20:01:33Z","subjects":["plasmonics","metal-insulator-metal nanocavity","nonlinear optics","second-harmonic generation","upconverted photoluminescence","nano-optoelectrode","nanoimprint lithography","cyber-physical-biological systems","bio-interface"],"languages":["en"],"rights":["Creative Commons Attribution 4.0 International"],"rights_urls":["http://creativecommons.org/licenses/by/4.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:46940"],"render_values":[{"text":"vt_gsexam:46940","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143132","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143132","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143132","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Zhou, Wei"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Jia, Xiaoting","Buehrer, R. Michael","Tian, Zhenhua","Lin, Zin"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Mejia, Elieser A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-05-22T08:00:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-05-22T08:00:56Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-05-21"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["plasmonics","metal-insulator-metal nanocavity","nonlinear optics","second-harmonic generation","upconverted photoluminescence","nano-optoelectrode","nanoimprint lithography","cyber-physical-biological systems","bio-interface"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Creative Commons Attribution 4.0 International"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://creativecommons.org/licenses/by/4.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:46940"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143132"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation investigates and engineers the light–matter interactions of metal–insulator–metal (MIM) nanolaminate nanocavities to realize broadband hybrid electro-optical transducer arrays for cyber-physical-biological systems (CPBS). The vertically stacked MIM architecture supports two spatially overlapping magnetoelectric resonances whose spectral positions and optical cross-sections are tunable through the metal-to-insulator thickness ratio at a fixed device footprint, a capability unique among plasmonic nanostructure geometries that enables engineering of the local density of optical states across the visible to near-infrared without enlarging the transducers footprint. In addition to this electromagnetic foundation, new nanoimprint lithography strategies are developed to pattern MIM nanocavity arrays onto biocompatible substrates including flexible polymer meshes and three-dimensional micropillar architectures, achieving SERS enhancement factors exceeding 10^7 with high spatial uniformity. Deliberate geometric symmetry breaking via oblique thin-film deposition simultaneously activates multiple nonlinear optical channels, including second-harmonic generation, third-harmonic generation, and upconverted photoluminescence, from the same nanostructure across a broad near-infrared excitation range, while anti-correlated interfacial sensitivity between coherent and incoherent channels provides a self-referencing detection modality without exogenous labels. Integration of electrical functionality through a co-design framework, that is in which the same oblique deposition step that activates dark plasmonic modes also forms the vertical electrical interconnect, yields nano-optoelectrode arrays capable of recording synchronized cardiomyocyte action potentials alongside optical transduction. In the electrochemical domain, correlated linear Raman signals resolve transient reaction intermediates invisible to electrical measurement alone, while applied voltage simultaneously and independently modulates second-harmonic generation through Fermi-level shifts at the metal–electrolyte interface and upconverted photoluminescence through hot-carrier interband dynamics, demonstrating mechanistically orthogonal optical readout of interfacial electronic structure. Together, these platforms establish MIM nanolaminate nanocavities as unified transducer building blocks for next-generation CPBS biointerfaces spanning neural recording, organoid integration, and all-optical voltage sensing."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Every heartbeat, thought, and immune response is the result of billions of cells communicating through electrical signals and molecular messengers simultaneously. Researchers have long wanted to listen to these conversations in real time and, when something goes wrong, to respond in kind. The difficulty is that our best tools are still single-channel: electrodes capture electrical activity but say nothing about the chemistry happening at the same moment, while optical microscopes can identify individual molecules but require chemical dyes and cannot run indefinitely without damaging the tissue. No single device has been able to capture the full picture at once, from the same location, at the same time.This dissertation describes the design and demonstration of a device small enough to sit beside a single cell that combines electrical and optical sensing in one platform. Its core element is a nanoscale stack of gold and glass layers that acts as a microscopic light trap, squeezing laser light into a space so small that it amplifies the faint optical signals from nearby molecules by factors of ten million or more. enough to identify chemicals by their unique vibrational fingerprints without any dyes. The same stack, by adjusting only the thicknesses of its layers and adding conductive interconnects, can also generate frequency-doubled light, emit a glow from energetically excited electrons, and record electrical signals from adjacent cells. All of these capabilities emerge from the same underlying physics and from the same structure, without enlarging the device footprint. Translating this physics into a working bio-interface required making the devices manufacturable on soft, curved, biocompatible materials using a nanoscale stamping process, adding a thin electrical connection without degrading the optical performance, and confirming that living cells are unharmed by the surface. Heart muscle cells cultured directly on the device grew normally, formed synchronized beating networks, and produced clean electrical recordings, validating the platform for biological use. With electrical and optical channels operating together, the device was then used to track fleeting chemical intermediate states during an electrochemical reaction that are invisible to electrical measurement alone, and to show that an applied voltage simultaneously modulates multiple distinct nonlinear optical signals, each reporting on a different physical property of the electrode surface. The broader goal is a new class of devices in which electronics, photonics, and living systems are coupled in continuous, real-time feedback loops, measuring biological states, computing responses, and delivering precisely targeted stimuli through the same interface."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Engineering Plasmonic Transducer Arrays for Cyber-Physical-Biological Systems: From Nanoimprinted Bio-Interfaces to Electro-Optical Nanocavities"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Zhou, Wei"],"dc:contributor.committeemember":["Jia, Xiaoting","Buehrer, R. Michael","Tian, Zhenhua","Lin, Zin"],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Mejia, Elieser A."],"dc:date.accessioned":["2026-05-22T08:00:56Z"],"dc:date.available":["2026-05-22T08:00:56Z"],"dc:date.issued":["2026-05-21"],"dc:description.abstract":["This dissertation investigates and engineers the light–matter interactions of metal–insulator–metal (MIM) nanolaminate nanocavities to realize broadband hybrid electro-optical transducer arrays for cyber-physical-biological systems (CPBS). The vertically stacked MIM architecture supports two spatially overlapping magnetoelectric resonances whose spectral positions and optical cross-sections are tunable through the metal-to-insulator thickness ratio at a fixed device footprint, a capability unique among plasmonic nanostructure geometries that enables engineering of the local density of optical states across the visible to near-infrared without enlarging the transducers footprint. In addition to this electromagnetic foundation, new nanoimprint lithography strategies are developed to pattern MIM nanocavity arrays onto biocompatible substrates including flexible polymer meshes and three-dimensional micropillar architectures, achieving SERS enhancement factors exceeding 10^7 with high spatial uniformity. Deliberate geometric symmetry breaking via oblique thin-film deposition simultaneously activates multiple nonlinear optical channels, including second-harmonic generation, third-harmonic generation, and upconverted photoluminescence, from the same nanostructure across a broad near-infrared excitation range, while anti-correlated interfacial sensitivity between coherent and incoherent channels provides a self-referencing detection modality without exogenous labels. Integration of electrical functionality through a co-design framework, that is in which the same oblique deposition step that activates dark plasmonic modes also forms the vertical electrical interconnect, yields nano-optoelectrode arrays capable of recording synchronized cardiomyocyte action potentials alongside optical transduction. In the electrochemical domain, correlated linear Raman signals resolve transient reaction intermediates invisible to electrical measurement alone, while applied voltage simultaneously and independently modulates second-harmonic generation through Fermi-level shifts at the metal–electrolyte interface and upconverted photoluminescence through hot-carrier interband dynamics, demonstrating mechanistically orthogonal optical readout of interfacial electronic structure. Together, these platforms establish MIM nanolaminate nanocavities as unified transducer building blocks for next-generation CPBS biointerfaces spanning neural recording, organoid integration, and all-optical voltage sensing."],"dc:description.abstractgeneral":["Every heartbeat, thought, and immune response is the result of billions of cells communicating through electrical signals and molecular messengers simultaneously. Researchers have long wanted to listen to these conversations in real time and, when something goes wrong, to respond in kind. The difficulty is that our best tools are still single-channel: electrodes capture electrical activity but say nothing about the chemistry happening at the same moment, while optical microscopes can identify individual molecules but require chemical dyes and cannot run indefinitely without damaging the tissue. No single device has been able to capture the full picture at once, from the same location, at the same time.This dissertation describes the design and demonstration of a device small enough to sit beside a single cell that combines electrical and optical sensing in one platform. Its core element is a nanoscale stack of gold and glass layers that acts as a microscopic light trap, squeezing laser light into a space so small that it amplifies the faint optical signals from nearby molecules by factors of ten million or more. enough to identify chemicals by their unique vibrational fingerprints without any dyes. The same stack, by adjusting only the thicknesses of its layers and adding conductive interconnects, can also generate frequency-doubled light, emit a glow from energetically excited electrons, and record electrical signals from adjacent cells. All of these capabilities emerge from the same underlying physics and from the same structure, without enlarging the device footprint. Translating this physics into a working bio-interface required making the devices manufacturable on soft, curved, biocompatible materials using a nanoscale stamping process, adding a thin electrical connection without degrading the optical performance, and confirming that living cells are unharmed by the surface. Heart muscle cells cultured directly on the device grew normally, formed synchronized beating networks, and produced clean electrical recordings, validating the platform for biological use. With electrical and optical channels operating together, the device was then used to track fleeting chemical intermediate states during an electrochemical reaction that are invisible to electrical measurement alone, and to show that an applied voltage simultaneously modulates multiple distinct nonlinear optical signals, each reporting on a different physical property of the electrode surface. The broader goal is a new class of devices in which electronics, photonics, and living systems are coupled in continuous, real-time feedback loops, measuring biological states, computing responses, and delivering precisely targeted stimuli through the same interface."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:46940"],"dc:identifier.uri":["https://hdl.handle.net/10919/143132"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["Creative Commons Attribution 4.0 International"],"dc:rights.uri":["http://creativecommons.org/licenses/by/4.0/"],"dc:subject":["plasmonics","metal-insulator-metal nanocavity","nonlinear optics","second-harmonic generation","upconverted photoluminescence","nano-optoelectrode","nanoimprint lithography","cyber-physical-biological systems","bio-interface"],"dc:title":["Engineering Plasmonic Transducer Arrays for Cyber-Physical-Biological Systems: From Nanoimprinted Bio-Interfaces to Electro-Optical Nanocavities"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:01:33Z"}