{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143359"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143359","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Lead Solder Contamination of Drinking Water: Water Corrosivity, Inhibition, and Limitations to Existing Understanding","abstract":"Lead ingestion via potable water is a public health concern, especially for vulnerable populations. Lead solder in building plumbing can be a dangerous source of water lead contamination. In the presence of corrosive water, lead-tin soldered copper joints form a galvanic cell that dramatically accelerates lead release. Utilities that are considering source water or treatment changes in response to recent regulations, including the LCRI, PFAS contamination levels, and sustainability requirements, or whose source waters are facing increased chloride or nitrate pollution, need guidance on the corrosivity of water to lead-tin solder and how to control it when necessary. Phosphate inhibitors are used by about half of all water utilities in the U.S., partly to reduce lead in water from leaded brass, lead pipe, and lead solder. Orthophosphate alone consistently reduces lead release from brass and lead pipe but often has little effect on lead-tin solder, and occasionally even worsens the situation. In contrast, zinc orthophosphate has outperformed orthophosphate in several studies. Chapter 2 delves into the effectiveness of orthophosphate and zinc orthophosphate in a low alkaline, high conductivity water synthesized in the laboratory. Inhibitor performance was examined at pH 6.5, 7.5, 8.5, 9.5, and 10.5, with incremental changes designed to increase corrosivity by the addition of chloride and/or nitrate. Zinc orthophosphate was ineffective at reducing lead at pH 6.5 and pH 10.5, but always reduced lead release at pHs 7.5 - 9.5 when compared to both the control and orthophosphate. At pH 8.5, dosing zinc orthophosphate reduced lead by 94-96% compared to conditions with no inhibitor or with phosphate – consistent with expectations based on a protective effect from zinc phosphate scale. Studies with a traditional galvanic corrosion cell consisting of a separate lead-tin anode and copper cathode had little or no correlation to trends in lead release that occurred with simulated joints in which lead-tin solder directly contacted copper. However, situations with very low lead release were generally associated with a 10X increase in electrical resistance using the cell. Recent experiences with solder corrosion at water utilities and in bench-scale laboratory studies raised concern about limitations to existing guidance about corrosive waters. The same low-alkalinity water used in Chapter 2 was modified in Chapter 3 to assess limitations of corrosion control guidance based on chloride to sulfate mass ratio (CSMR) and nitrate. Eight waters, four of which consisted of 10 mg/L sulfate at 0.8, 1, 4.8, and 41 CSMR, and the other four consisted of 100 mg/L sulfate at 0.3, 0.5, 4.1, and 38 CSMR, were synthesized and tested with copper and lead-tin solder coupons. At 0.3 CSMR, lead release was very low at less than 30 ppb, confirming expectations based on guidance for predicating non-corrosive waters. But a water with a significantly greater CSMR (0.8) was even less corrosive, experimentally proving that many waters with CSMRs higher than 0.5 will not have serious lead problems. Moreover, observations that less lead release occurred at a higher CSMR (0.8) with 10 mg/L sulfate than at an extremely low CSMR (0.3) with 100 mg/L sulfate revealed that higher conductivity could also cause higher release. Prior research using electrochemical cells predicted effects of adding nitrate would not follow clear trends. Using the second stage of the study to address this prediction, added nitrate at times increased, had no effect, and occasionally even decreased lead release depending on the concentrations of sulfate and chloride present. The corrosive effects of adding 10 mg/L nitrate ranged from a 7,739% increase in lead in one condition to an 88% decrease in another. The impact of nitrate on lead release is indeed complex and cannot yet be predicted with simple theories or empirical relationships. In contrast, there were strong correlations between conductivity and lead release, suggesting that it has an underappreciated role in controlling water corrosivity in relation to lead release from lead-tin solder. Overall, this study highlighted the concerning limitations of existing guidance and understanding regarding the control of lead-tin solder corrosion. Unfortunately, this guidance cannot be easily corrected or refined. Trial and error bench scale studies are the best practical approach to identifying problems (and solutions) to this extremely complicated challenge.","abstract_html":"Lead ingestion via potable water is a public health concern, especially for vulnerable populations. Lead solder in building plumbing can be a dangerous source of water lead contamination. In the presence of corrosive water, lead-tin soldered copper joints form a galvanic cell that dramatically accelerates lead release. Utilities that are considering source water or treatment changes in response to recent regulations, including the LCRI, PFAS contamination levels, and sustainability requirements, or whose source waters are facing increased chloride or nitrate pollution, need guidance on the corrosivity of water to lead-tin solder and how to control it when necessary. Phosphate inhibitors are used by about half of all water utilities in the U.S., partly to reduce lead in water from leaded brass, lead pipe, and lead solder. Orthophosphate alone consistently reduces lead release from brass and lead pipe but often has little effect on lead-tin solder, and occasionally even worsens the situation. In contrast, zinc orthophosphate has outperformed orthophosphate in several studies. Chapter 2 delves into the effectiveness of orthophosphate and zinc orthophosphate in a low alkaline, high conductivity water synthesized in the laboratory. Inhibitor performance was examined at pH 6.5, 7.5, 8.5, 9.5, and 10.5, with incremental changes designed to increase corrosivity by the addition of chloride and/or nitrate. Zinc orthophosphate was ineffective at reducing lead at pH 6.5 and pH 10.5, but always reduced lead release at pHs 7.5 - 9.5 when compared to both the control and orthophosphate. At pH 8.5, dosing zinc orthophosphate reduced lead by 94-96% compared to conditions with no inhibitor or with phosphate – consistent with expectations based on a protective effect from zinc phosphate scale. Studies with a traditional galvanic corrosion cell consisting of a separate lead-tin anode and copper cathode had little or no correlation to trends in lead release that occurred with simulated joints in which lead-tin solder directly contacted copper. However, situations with very low lead release were generally associated with a 10X increase in electrical resistance using the cell. Recent experiences with solder corrosion at water utilities and in bench-scale laboratory studies raised concern about limitations to existing guidance about corrosive waters. The same low-alkalinity water used in Chapter 2 was modified in Chapter 3 to assess limitations of corrosion control guidance based on chloride to sulfate mass ratio (CSMR) and nitrate. Eight waters, four of which consisted of 10 mg/L sulfate at 0.8, 1, 4.8, and 41 CSMR, and the other four consisted of 100 mg/L sulfate at 0.3, 0.5, 4.1, and 38 CSMR, were synthesized and tested with copper and lead-tin solder coupons. At 0.3 CSMR, lead release was very low at less than 30 ppb, confirming expectations based on guidance for predicating non-corrosive waters. But a water with a significantly greater CSMR (0.8) was even less corrosive, experimentally proving that many waters with CSMRs higher than 0.5 will not have serious lead problems. Moreover, observations that less lead release occurred at a higher CSMR (0.8) with 10 mg/L sulfate than at an extremely low CSMR (0.3) with 100 mg/L sulfate revealed that higher conductivity could also cause higher release. Prior research using electrochemical cells predicted effects of adding nitrate would not follow clear trends. Using the second stage of the study to address this prediction, added nitrate at times increased, had no effect, and occasionally even decreased lead release depending on the concentrations of sulfate and chloride present. The corrosive effects of adding 10 mg/L nitrate ranged from a 7,739% increase in lead in one condition to an 88% decrease in another. The impact of nitrate on lead release is indeed complex and cannot yet be predicted with simple theories or empirical relationships. In contrast, there were strong correlations between conductivity and lead release, suggesting that it has an underappreciated role in controlling water corrosivity in relation to lead release from lead-tin solder. Overall, this study highlighted the concerning limitations of existing guidance and understanding regarding the control of lead-tin solder corrosion. Unfortunately, this guidance cannot be easily corrected or refined. Trial and error bench scale studies are the best practical approach to identifying problems (and solutions) to this extremely complicated challenge.","abstract_has_math":false,"creators":["Parker, Kaitlyn O."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Environmental Engineering","degree_department":"Environmental Science and Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Edwards, Marc A."],"committee_members":["Parks, Jeffrey L.","Sarver, Emily A."],"year":2026,"date_issued":"2026-06-11","date_published":"2026-06-11","updated_at":"2026-11-18T20:18:39Z","subjects":["Galvanic Corrosion","Lead Solder","Inhibitors","Chloride","Sulfate","Nitrate"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:46918"],"render_values":[{"text":"vt_gsexam:46918","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143359","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143359","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143359","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Edwards, Marc A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Parks, Jeffrey L.","Sarver, Emily A."]},{"key":"dc:contributor.department","label":"Department","values":["Environmental Science and Engineering"]},{"key":"dc:creator","label":"Author","values":["Parker, Kaitlyn O."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-06-12T08:00:27Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-06-12T08:00:27Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-06-11"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Galvanic Corrosion","Lead Solder","Inhibitors","Chloride","Sulfate","Nitrate"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:46918"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143359"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Lead ingestion via potable water is a public health concern, especially for vulnerable populations. Lead solder in building plumbing can be a dangerous source of water lead contamination. In the presence of corrosive water, lead-tin soldered copper joints form a galvanic cell that dramatically accelerates lead release. Utilities that are considering source water or treatment changes in response to recent regulations, including the LCRI, PFAS contamination levels, and sustainability requirements, or whose source waters are facing increased chloride or nitrate pollution, need guidance on the corrosivity of water to lead-tin solder and how to control it when necessary. Phosphate inhibitors are used by about half of all water utilities in the U.S., partly to reduce lead in water from leaded brass, lead pipe, and lead solder. Orthophosphate alone consistently reduces lead release from brass and lead pipe but often has little effect on lead-tin solder, and occasionally even worsens the situation. In contrast, zinc orthophosphate has outperformed orthophosphate in several studies. Chapter 2 delves into the effectiveness of orthophosphate and zinc orthophosphate in a low alkaline, high conductivity water synthesized in the laboratory. Inhibitor performance was examined at pH 6.5, 7.5, 8.5, 9.5, and 10.5, with incremental changes designed to increase corrosivity by the addition of chloride and/or nitrate. Zinc orthophosphate was ineffective at reducing lead at pH 6.5 and pH 10.5, but always reduced lead release at pHs 7.5 - 9.5 when compared to both the control and orthophosphate. At pH 8.5, dosing zinc orthophosphate reduced lead by 94-96% compared to conditions with no inhibitor or with phosphate – consistent with expectations based on a protective effect from zinc phosphate scale. Studies with a traditional galvanic corrosion cell consisting of a separate lead-tin anode and copper cathode had little or no correlation to trends in lead release that occurred with simulated joints in which lead-tin solder directly contacted copper. However, situations with very low lead release were generally associated with a 10X increase in electrical resistance using the cell. Recent experiences with solder corrosion at water utilities and in bench-scale laboratory studies raised concern about limitations to existing guidance about corrosive waters. The same low-alkalinity water used in Chapter 2 was modified in Chapter 3 to assess limitations of corrosion control guidance based on chloride to sulfate mass ratio (CSMR) and nitrate. Eight waters, four of which consisted of 10 mg/L sulfate at 0.8, 1, 4.8, and 41 CSMR, and the other four consisted of 100 mg/L sulfate at 0.3, 0.5, 4.1, and 38 CSMR, were synthesized and tested with copper and lead-tin solder coupons. At 0.3 CSMR, lead release was very low at less than 30 ppb, confirming expectations based on guidance for predicating non-corrosive waters. But a water with a significantly greater CSMR (0.8) was even less corrosive, experimentally proving that many waters with CSMRs higher than 0.5 will not have serious lead problems. Moreover, observations that less lead release occurred at a higher CSMR (0.8) with 10 mg/L sulfate than at an extremely low CSMR (0.3) with 100 mg/L sulfate revealed that higher conductivity could also cause higher release. Prior research using electrochemical cells predicted effects of adding nitrate would not follow clear trends. Using the second stage of the study to address this prediction, added nitrate at times increased, had no effect, and occasionally even decreased lead release depending on the concentrations of sulfate and chloride present. The corrosive effects of adding 10 mg/L nitrate ranged from a 7,739% increase in lead in one condition to an 88% decrease in another. The impact of nitrate on lead release is indeed complex and cannot yet be predicted with simple theories or empirical relationships. In contrast, there were strong correlations between conductivity and lead release, suggesting that it has an underappreciated role in controlling water corrosivity in relation to lead release from lead-tin solder. Overall, this study highlighted the concerning limitations of existing guidance and understanding regarding the control of lead-tin solder corrosion. Unfortunately, this guidance cannot be easily corrected or refined. Trial and error bench scale studies are the best practical approach to identifying problems (and solutions) to this extremely complicated challenge."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Lead ingestion by drinking tap water is sometimes a significant public health concern, particularly for vulnerable populations. Lead–tin solder used in old homes built before about 1986 can be a major source of lead in water. When in contact with corrosive water, soldered copper joints can form galvanic cells that accelerate lead contamination of the water, whereas non-corrosive waters keep lead levels low. As utilities consider changes to source water or treatment – driven by regulations like the Lead and Copper Rule Improvements (LCRI), PFAS concerns, and sustainability goals – and as source waters experience rising chloride or nitrate levels from pollution, there is a growing need for improved guidance on what causes a water to be corrosive and effective control strategies. Phosphate-based corrosion inhibitors are widely used in the United States, with approximately half of utilities applying them to reduce lead release from lead-containing plumbing materials. While orthophosphate is generally effective for controlling lead release from older brass and lead pipe, it often has limited effectiveness for lead–tin solder and can occasionally worsen lead release. In contrast, zinc orthophosphate has demonstrated superior performance in several studies. Chapter 2 evaluates inhibitor performance in a low-alkalinity, high-conductivity synthetic water across a pH range of 6.5 to 10.5, with corrosivity increased through additions of chloride and/or nitrate. Zinc orthophosphate was ineffective at pH 6.5 and 10.5 but consistently reduced lead release at pH 7.5–9.5 relative to both the control and orthophosphate-only conditions. At pH 8.5, zinc orthophosphate reduced lead concentrations by 94–96% compared to the control and orthophosphate, likely due to the formation of protective zinc phosphate scale. Traditional galvanic corrosion cell tests (separate lead–tin anode and copper cathode) showed little correlation with results from simulated soldered joints, where solder is in direct electrical contact with copper. However, very low lead release was generally associated with about a tenfold increase in electrical resistance in the electrochemical cell. Chapter 3 examines limitations of existing corrosivity guidance, particularly the chloride-to-sulfate mass ratio (CSMR) and nitrate effects. Using the same base water from Chapter 2, sixteen conditions were tested with 10 and 100 mg/L sulfate concentrations, with CSMRs from 0.3 to 41. Lead release was relatively low when CSMR was < 1.0, supporting the traditional CSMR corrosivity guideline under those conditions, but discrepancies within the 0.3-1.0 CSMR range challenge broad applications of CSMR guidance in corrosivity prediction. The effects of nitrate were highly variable and difficult to predict. Incrementally adding 1 to 10 mg/L nitrate increased, sometimes decreased, or had no effect on lead release, depending on the level of sulfate and chloride present. Adding 10 mg/L nitrate increased lead as much as 7,739% higher compared to zero nitrate, or could reduce lead release by up to 88% in another extreme example. These findings confirm that nitrate impacts cannot be reliably predicted using existing models or simple empirical relationships. In contrast, lead release showed strong correlation with conductivity, suggesting it may play an underappreciated role in controlling solder corrosion. Overall, this work highlights significant limitations in current corrosion control guidance for lead–tin solder. Given the complexity and variability of system behavior, as well as the serious consequences of lead contamination, existing rules and predictive ability are inadequate. Utility-specific bench-scale test results are still the best approach for diagnosing and mitigating problems associated with lead solder corrosion."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Lead Solder Contamination of Drinking Water: Water Corrosivity, Inhibition, and Limitations to Existing Understanding"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Edwards, Marc A."],"dc:contributor.committeemember":["Parks, Jeffrey L.","Sarver, Emily A."],"dc:contributor.department":["Environmental Science and Engineering"],"dc:creator":["Parker, Kaitlyn O."],"dc:date.accessioned":["2026-06-12T08:00:27Z"],"dc:date.available":["2026-06-12T08:00:27Z"],"dc:date.issued":["2026-06-11"],"dc:description.abstract":["Lead ingestion via potable water is a public health concern, especially for vulnerable populations. Lead solder in building plumbing can be a dangerous source of water lead contamination. In the presence of corrosive water, lead-tin soldered copper joints form a galvanic cell that dramatically accelerates lead release. Utilities that are considering source water or treatment changes in response to recent regulations, including the LCRI, PFAS contamination levels, and sustainability requirements, or whose source waters are facing increased chloride or nitrate pollution, need guidance on the corrosivity of water to lead-tin solder and how to control it when necessary. Phosphate inhibitors are used by about half of all water utilities in the U.S., partly to reduce lead in water from leaded brass, lead pipe, and lead solder. Orthophosphate alone consistently reduces lead release from brass and lead pipe but often has little effect on lead-tin solder, and occasionally even worsens the situation. In contrast, zinc orthophosphate has outperformed orthophosphate in several studies. Chapter 2 delves into the effectiveness of orthophosphate and zinc orthophosphate in a low alkaline, high conductivity water synthesized in the laboratory. Inhibitor performance was examined at pH 6.5, 7.5, 8.5, 9.5, and 10.5, with incremental changes designed to increase corrosivity by the addition of chloride and/or nitrate. Zinc orthophosphate was ineffective at reducing lead at pH 6.5 and pH 10.5, but always reduced lead release at pHs 7.5 - 9.5 when compared to both the control and orthophosphate. At pH 8.5, dosing zinc orthophosphate reduced lead by 94-96% compared to conditions with no inhibitor or with phosphate – consistent with expectations based on a protective effect from zinc phosphate scale. Studies with a traditional galvanic corrosion cell consisting of a separate lead-tin anode and copper cathode had little or no correlation to trends in lead release that occurred with simulated joints in which lead-tin solder directly contacted copper. However, situations with very low lead release were generally associated with a 10X increase in electrical resistance using the cell. Recent experiences with solder corrosion at water utilities and in bench-scale laboratory studies raised concern about limitations to existing guidance about corrosive waters. The same low-alkalinity water used in Chapter 2 was modified in Chapter 3 to assess limitations of corrosion control guidance based on chloride to sulfate mass ratio (CSMR) and nitrate. Eight waters, four of which consisted of 10 mg/L sulfate at 0.8, 1, 4.8, and 41 CSMR, and the other four consisted of 100 mg/L sulfate at 0.3, 0.5, 4.1, and 38 CSMR, were synthesized and tested with copper and lead-tin solder coupons. At 0.3 CSMR, lead release was very low at less than 30 ppb, confirming expectations based on guidance for predicating non-corrosive waters. But a water with a significantly greater CSMR (0.8) was even less corrosive, experimentally proving that many waters with CSMRs higher than 0.5 will not have serious lead problems. Moreover, observations that less lead release occurred at a higher CSMR (0.8) with 10 mg/L sulfate than at an extremely low CSMR (0.3) with 100 mg/L sulfate revealed that higher conductivity could also cause higher release. Prior research using electrochemical cells predicted effects of adding nitrate would not follow clear trends. Using the second stage of the study to address this prediction, added nitrate at times increased, had no effect, and occasionally even decreased lead release depending on the concentrations of sulfate and chloride present. The corrosive effects of adding 10 mg/L nitrate ranged from a 7,739% increase in lead in one condition to an 88% decrease in another. The impact of nitrate on lead release is indeed complex and cannot yet be predicted with simple theories or empirical relationships. In contrast, there were strong correlations between conductivity and lead release, suggesting that it has an underappreciated role in controlling water corrosivity in relation to lead release from lead-tin solder. Overall, this study highlighted the concerning limitations of existing guidance and understanding regarding the control of lead-tin solder corrosion. Unfortunately, this guidance cannot be easily corrected or refined. Trial and error bench scale studies are the best practical approach to identifying problems (and solutions) to this extremely complicated challenge."],"dc:description.abstractgeneral":["Lead ingestion by drinking tap water is sometimes a significant public health concern, particularly for vulnerable populations. Lead–tin solder used in old homes built before about 1986 can be a major source of lead in water. When in contact with corrosive water, soldered copper joints can form galvanic cells that accelerate lead contamination of the water, whereas non-corrosive waters keep lead levels low. As utilities consider changes to source water or treatment – driven by regulations like the Lead and Copper Rule Improvements (LCRI), PFAS concerns, and sustainability goals – and as source waters experience rising chloride or nitrate levels from pollution, there is a growing need for improved guidance on what causes a water to be corrosive and effective control strategies. Phosphate-based corrosion inhibitors are widely used in the United States, with approximately half of utilities applying them to reduce lead release from lead-containing plumbing materials. While orthophosphate is generally effective for controlling lead release from older brass and lead pipe, it often has limited effectiveness for lead–tin solder and can occasionally worsen lead release. In contrast, zinc orthophosphate has demonstrated superior performance in several studies. Chapter 2 evaluates inhibitor performance in a low-alkalinity, high-conductivity synthetic water across a pH range of 6.5 to 10.5, with corrosivity increased through additions of chloride and/or nitrate. Zinc orthophosphate was ineffective at pH 6.5 and 10.5 but consistently reduced lead release at pH 7.5–9.5 relative to both the control and orthophosphate-only conditions. At pH 8.5, zinc orthophosphate reduced lead concentrations by 94–96% compared to the control and orthophosphate, likely due to the formation of protective zinc phosphate scale. Traditional galvanic corrosion cell tests (separate lead–tin anode and copper cathode) showed little correlation with results from simulated soldered joints, where solder is in direct electrical contact with copper. However, very low lead release was generally associated with about a tenfold increase in electrical resistance in the electrochemical cell. Chapter 3 examines limitations of existing corrosivity guidance, particularly the chloride-to-sulfate mass ratio (CSMR) and nitrate effects. Using the same base water from Chapter 2, sixteen conditions were tested with 10 and 100 mg/L sulfate concentrations, with CSMRs from 0.3 to 41. Lead release was relatively low when CSMR was < 1.0, supporting the traditional CSMR corrosivity guideline under those conditions, but discrepancies within the 0.3-1.0 CSMR range challenge broad applications of CSMR guidance in corrosivity prediction. The effects of nitrate were highly variable and difficult to predict. Incrementally adding 1 to 10 mg/L nitrate increased, sometimes decreased, or had no effect on lead release, depending on the level of sulfate and chloride present. Adding 10 mg/L nitrate increased lead as much as 7,739% higher compared to zero nitrate, or could reduce lead release by up to 88% in another extreme example. These findings confirm that nitrate impacts cannot be reliably predicted using existing models or simple empirical relationships. In contrast, lead release showed strong correlation with conductivity, suggesting it may play an underappreciated role in controlling solder corrosion. Overall, this work highlights significant limitations in current corrosion control guidance for lead–tin solder. Given the complexity and variability of system behavior, as well as the serious consequences of lead contamination, existing rules and predictive ability are inadequate. Utility-specific bench-scale test results are still the best approach for diagnosing and mitigating problems associated with lead solder corrosion."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:46918"],"dc:identifier.uri":["https://hdl.handle.net/10919/143359"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Galvanic Corrosion","Lead Solder","Inhibitors","Chloride","Sulfate","Nitrate"],"dc:title":["Lead Solder Contamination of Drinking Water: Water Corrosivity, Inhibition, and Limitations to Existing Understanding"],"dc:type":["Thesis"],"thesis:degree_discipline":["Environmental Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:18:39Z"}