{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143363"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143363","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Inhibition and Recovery of Anammox Bacteria on Biofilm Carriers Exposed to Free Ammonia and Free Nitrous Acid","abstract":"Anaerobic ammonium oxidation (anammox) is an energy-efficient biological process for nitrogen removal that has been widely implemented in sidestream systems, expanded into mainstream applications, and increasingly applied to high-strength industrial waste streams. Despite its advantages, anammox performance is sensitive to inhibition by free ammonia (FA) and free nitrous acid (FNA). While inhibitory thresholds for these species are well documented, less is understood about the reversibility of inhibition and the extent to which recovery depends on the pathway by which inhibitory conditions are achieved, defined here as whether inhibition results from changes in pH or changes in total nitrogen concentration. This study evaluated anammox inhibition and recovery under controlled FA and FNA exposures using bench-scale moving bed biofilm reactors (MBBRs) with carriers with mature biofilm from a sidestream PNA process. Biofilm carriers were subjected to approximately 20-hour exposure periods across a range of ammonia and nitrite concentrations, with pH-controlled conditions used to isolate ammonia and nitrite speciation, enabling independent evaluation of FA and FNA formation. Maximum anammox activity tests (MAATs) were conducted before, during, and after exposure to quantify percent inhibition, recovery potential, and time to maximum recovery. Statistical analyses compared FA and FNA concentrations with total species metrics, including total ammonia nitrogen (TAN) and total nitrite species (TNS). Results demonstrated fundamentally different inhibition and recovery dynamics for FA and FNA. FNA caused rapid and near-complete inhibition (>85%) at low concentrations (<0.04 mg N/L), yet recovery was consistently high (>85–100%) following removal of the inhibitory condition. In contrast, FA produced more variable inhibition but resulted in reduced recovery potential and longer recovery times at elevated concentrations. Notably, TAN exhibited stronger relationships with both inhibition (adjusted R² = 0.639, p = 0.0117) and recovery behavior than FA alone, indicating that ammonia-related inhibition is not fully described by NH₃ concentration in isolation. Recovery time increased significantly with FA concentration (adjusted R² = 0.509, p = 0.0345), whereas no meaningful relationship was observed for FNA. These findings demonstrate that FNA acts as a rapid but largely reversible inhibitor, while FA exposure leads to more persistent inhibition with reduced recoverability. The results further show that anammox response depends not only on inhibitor concentration, but also on how those conditions are established through interactions between pH and bulk nitrogen. This distinction is particularly relevant for sidestream and high-strength treatment systems, where controlling both nitrogen loading and pH is critical for maintaining stable and resilient anammox performance.","abstract_html":"Anaerobic ammonium oxidation (anammox) is an energy-efficient biological process for nitrogen removal that has been widely implemented in sidestream systems, expanded into mainstream applications, and increasingly applied to high-strength industrial waste streams. Despite its advantages, anammox performance is sensitive to inhibition by free ammonia (FA) and free nitrous acid (FNA). While inhibitory thresholds for these species are well documented, less is understood about the reversibility of inhibition and the extent to which recovery depends on the pathway by which inhibitory conditions are achieved, defined here as whether inhibition results from changes in pH or changes in total nitrogen concentration. This study evaluated anammox inhibition and recovery under controlled FA and FNA exposures using bench-scale moving bed biofilm reactors (MBBRs) with carriers with mature biofilm from a sidestream PNA process. Biofilm carriers were subjected to approximately 20-hour exposure periods across a range of ammonia and nitrite concentrations, with pH-controlled conditions used to isolate ammonia and nitrite speciation, enabling independent evaluation of FA and FNA formation. Maximum anammox activity tests (MAATs) were conducted before, during, and after exposure to quantify percent inhibition, recovery potential, and time to maximum recovery. Statistical analyses compared FA and FNA concentrations with total species metrics, including total ammonia nitrogen (TAN) and total nitrite species (TNS). Results demonstrated fundamentally different inhibition and recovery dynamics for FA and FNA. FNA caused rapid and near-complete inhibition (&gt;85%) at low concentrations (&lt;0.04 mg N/L), yet recovery was consistently high (&gt;85–100%) following removal of the inhibitory condition. In contrast, FA produced more variable inhibition but resulted in reduced recovery potential and longer recovery times at elevated concentrations. Notably, TAN exhibited stronger relationships with both inhibition (adjusted R² = 0.639, p = 0.0117) and recovery behavior than FA alone, indicating that ammonia-related inhibition is not fully described by NH₃ concentration in isolation. Recovery time increased significantly with FA concentration (adjusted R² = 0.509, p = 0.0345), whereas no meaningful relationship was observed for FNA. These findings demonstrate that FNA acts as a rapid but largely reversible inhibitor, while FA exposure leads to more persistent inhibition with reduced recoverability. The results further show that anammox response depends not only on inhibitor concentration, but also on how those conditions are established through interactions between pH and bulk nitrogen. This distinction is particularly relevant for sidestream and high-strength treatment systems, where controlling both nitrogen loading and pH is critical for maintaining stable and resilient anammox performance.","abstract_has_math":false,"creators":["Robinson, Francis Lester"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Pruden-Bagchi, Amy Jill","Bott, Charles B."],"committee_members":["Liao, Jingqiu"],"year":2026,"date_issued":"2026-06-11","date_published":"2026-06-11","updated_at":"2026-11-18T20:24:54Z","subjects":["Anammox","Free Ammonia","Free Nitrous Acid"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47368"],"render_values":[{"text":"vt_gsexam:47368","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143363","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143363","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143363","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Pruden-Bagchi, Amy Jill","Bott, Charles B."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Liao, Jingqiu"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Robinson, Francis Lester"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-06-12T08:01:06Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-06-12T08:01:06Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-06-11"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Anammox","Free Ammonia","Free Nitrous Acid"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47368"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143363"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Anaerobic ammonium oxidation (anammox) is an energy-efficient biological process for nitrogen removal that has been widely implemented in sidestream systems, expanded into mainstream applications, and increasingly applied to high-strength industrial waste streams. Despite its advantages, anammox performance is sensitive to inhibition by free ammonia (FA) and free nitrous acid (FNA). While inhibitory thresholds for these species are well documented, less is understood about the reversibility of inhibition and the extent to which recovery depends on the pathway by which inhibitory conditions are achieved, defined here as whether inhibition results from changes in pH or changes in total nitrogen concentration. This study evaluated anammox inhibition and recovery under controlled FA and FNA exposures using bench-scale moving bed biofilm reactors (MBBRs) with carriers with mature biofilm from a sidestream PNA process. Biofilm carriers were subjected to approximately 20-hour exposure periods across a range of ammonia and nitrite concentrations, with pH-controlled conditions used to isolate ammonia and nitrite speciation, enabling independent evaluation of FA and FNA formation. Maximum anammox activity tests (MAATs) were conducted before, during, and after exposure to quantify percent inhibition, recovery potential, and time to maximum recovery. Statistical analyses compared FA and FNA concentrations with total species metrics, including total ammonia nitrogen (TAN) and total nitrite species (TNS). Results demonstrated fundamentally different inhibition and recovery dynamics for FA and FNA. FNA caused rapid and near-complete inhibition (>85%) at low concentrations (<0.04 mg N/L), yet recovery was consistently high (>85–100%) following removal of the inhibitory condition. In contrast, FA produced more variable inhibition but resulted in reduced recovery potential and longer recovery times at elevated concentrations. Notably, TAN exhibited stronger relationships with both inhibition (adjusted R² = 0.639, p = 0.0117) and recovery behavior than FA alone, indicating that ammonia-related inhibition is not fully described by NH₃ concentration in isolation. Recovery time increased significantly with FA concentration (adjusted R² = 0.509, p = 0.0345), whereas no meaningful relationship was observed for FNA. These findings demonstrate that FNA acts as a rapid but largely reversible inhibitor, while FA exposure leads to more persistent inhibition with reduced recoverability. The results further show that anammox response depends not only on inhibitor concentration, but also on how those conditions are established through interactions between pH and bulk nitrogen. This distinction is particularly relevant for sidestream and high-strength treatment systems, where controlling both nitrogen loading and pH is critical for maintaining stable and resilient anammox performance."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Wastewater treatment plants rely on specialized bacteria to remove nitrogen and protect receiving waters. One of the most efficient of these processes, known as anammox, can remove nitrogen using far less energy and chemicals than conventional methods. However, this process is sensitive to certain forms of nitrogen that can temporarily or permanently disrupt bacterial activity. This study investigates how two key inhibitory compounds (free ammonia (FA) and free nitrous acid (FNA)) affect anammox bacteria and whether the system can recover after exposure. Using laboratory-scale reactors with bacteria from a full-scale treatment plant, the bacteria were exposed to controlled conditions that simulated real-world process upsets. Their performance was tracked before, during, and after exposure to determine how strongly they were inhibited and how quickly they recovered. The results show a clear difference between the two inhibitors. FNA caused severe but short-lived inhibition, with bacteria recovering almost completely once conditions improved. In contrast, FA led to longer-lasting damage, reducing the ability of the system to recover and increasing the time needed to return to normal performance. Importantly, overall ammonia levels (not just the free ammonia portion) were better predictors of system response, highlighting the role of pH and total nitrogen conditions in determining stability. These findings suggest that not all process upsets are equally harmful. Some conditions may temporarily reduce performance but allow for full recovery, while others can lead to longer-term damage. Understanding this difference can help wastewater operators avoid unnecessary system resets or biomass replacement and instead manage conditions to promote recovery. Overall, this work provides practical insight into how advanced nitrogen removal systems respond to stress and offers guidance for improving the reliability and resilience of wastewater treatment processes, particularly for high-strength industrial waste streams."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Inhibition and Recovery of Anammox Bacteria on Biofilm Carriers Exposed to Free Ammonia and Free Nitrous Acid"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Pruden-Bagchi, Amy Jill","Bott, Charles B."],"dc:contributor.committeemember":["Liao, Jingqiu"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:creator":["Robinson, Francis Lester"],"dc:date.accessioned":["2026-06-12T08:01:06Z"],"dc:date.available":["2026-06-12T08:01:06Z"],"dc:date.issued":["2026-06-11"],"dc:description.abstract":["Anaerobic ammonium oxidation (anammox) is an energy-efficient biological process for nitrogen removal that has been widely implemented in sidestream systems, expanded into mainstream applications, and increasingly applied to high-strength industrial waste streams. Despite its advantages, anammox performance is sensitive to inhibition by free ammonia (FA) and free nitrous acid (FNA). While inhibitory thresholds for these species are well documented, less is understood about the reversibility of inhibition and the extent to which recovery depends on the pathway by which inhibitory conditions are achieved, defined here as whether inhibition results from changes in pH or changes in total nitrogen concentration. This study evaluated anammox inhibition and recovery under controlled FA and FNA exposures using bench-scale moving bed biofilm reactors (MBBRs) with carriers with mature biofilm from a sidestream PNA process. Biofilm carriers were subjected to approximately 20-hour exposure periods across a range of ammonia and nitrite concentrations, with pH-controlled conditions used to isolate ammonia and nitrite speciation, enabling independent evaluation of FA and FNA formation. Maximum anammox activity tests (MAATs) were conducted before, during, and after exposure to quantify percent inhibition, recovery potential, and time to maximum recovery. Statistical analyses compared FA and FNA concentrations with total species metrics, including total ammonia nitrogen (TAN) and total nitrite species (TNS). Results demonstrated fundamentally different inhibition and recovery dynamics for FA and FNA. FNA caused rapid and near-complete inhibition (>85%) at low concentrations (<0.04 mg N/L), yet recovery was consistently high (>85–100%) following removal of the inhibitory condition. In contrast, FA produced more variable inhibition but resulted in reduced recovery potential and longer recovery times at elevated concentrations. Notably, TAN exhibited stronger relationships with both inhibition (adjusted R² = 0.639, p = 0.0117) and recovery behavior than FA alone, indicating that ammonia-related inhibition is not fully described by NH₃ concentration in isolation. Recovery time increased significantly with FA concentration (adjusted R² = 0.509, p = 0.0345), whereas no meaningful relationship was observed for FNA. These findings demonstrate that FNA acts as a rapid but largely reversible inhibitor, while FA exposure leads to more persistent inhibition with reduced recoverability. The results further show that anammox response depends not only on inhibitor concentration, but also on how those conditions are established through interactions between pH and bulk nitrogen. This distinction is particularly relevant for sidestream and high-strength treatment systems, where controlling both nitrogen loading and pH is critical for maintaining stable and resilient anammox performance."],"dc:description.abstractgeneral":["Wastewater treatment plants rely on specialized bacteria to remove nitrogen and protect receiving waters. One of the most efficient of these processes, known as anammox, can remove nitrogen using far less energy and chemicals than conventional methods. However, this process is sensitive to certain forms of nitrogen that can temporarily or permanently disrupt bacterial activity. This study investigates how two key inhibitory compounds (free ammonia (FA) and free nitrous acid (FNA)) affect anammox bacteria and whether the system can recover after exposure. Using laboratory-scale reactors with bacteria from a full-scale treatment plant, the bacteria were exposed to controlled conditions that simulated real-world process upsets. Their performance was tracked before, during, and after exposure to determine how strongly they were inhibited and how quickly they recovered. The results show a clear difference between the two inhibitors. FNA caused severe but short-lived inhibition, with bacteria recovering almost completely once conditions improved. In contrast, FA led to longer-lasting damage, reducing the ability of the system to recover and increasing the time needed to return to normal performance. Importantly, overall ammonia levels (not just the free ammonia portion) were better predictors of system response, highlighting the role of pH and total nitrogen conditions in determining stability. These findings suggest that not all process upsets are equally harmful. Some conditions may temporarily reduce performance but allow for full recovery, while others can lead to longer-term damage. Understanding this difference can help wastewater operators avoid unnecessary system resets or biomass replacement and instead manage conditions to promote recovery. Overall, this work provides practical insight into how advanced nitrogen removal systems respond to stress and offers guidance for improving the reliability and resilience of wastewater treatment processes, particularly for high-strength industrial waste streams."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:47368"],"dc:identifier.uri":["https://hdl.handle.net/10919/143363"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Anammox","Free Ammonia","Free Nitrous Acid"],"dc:title":["Inhibition and Recovery of Anammox Bacteria on Biofilm Carriers Exposed to Free Ammonia and Free Nitrous Acid"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:24:54Z"}