{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143490"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143490","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Experimental Tests of Wide Aspect Ratio Cross Laminated Timber – Steel Diaphragms for Hybrid Building Applications","abstract":"The purpose of this investigation is to identify the behavior of wide aspect ratio, cross-laminated timber (CLT) diaphragms, with steel gravity members, designed to meet the code requirements given in the 2021 Special Design Provisions for Wind and Seismic (SDPWS) (American Wood Council, 2020). To do so, three configurations with varied inter-panel connections were tested. To identify the impact of different inter-panel fasteners, metal surface splines with nails and screws were evaluated. The metal surface spline along the beam lines was then removed to test the use of the panel-beam connection as the inter-panel connection. Testing revealed an excess in strength capacity with the ASD design strength exceeded by a factor of 4.5-6 across all configurations compared to the required overstrength of 2.8. Due to the large overstrength, the diaphragm can be expected to remain elastic at design forces. Across the ASD design range, the configuration that included metal surface splines with screws had the highest stiffness followed closely by the configuration that relied on the panel-beam connection alone. The metal surface spline configuration with screws had a stiffness double that of the configuration with nails. The three deflection methods included in the investigation were able to more closely predict the diaphragm displacement when the fastener type included was limited to nails. When screws were introduced to the calculation, the deflections had larger overpredictions.","abstract_html":"The purpose of this investigation is to identify the behavior of wide aspect ratio, cross-laminated timber (CLT) diaphragms, with steel gravity members, designed to meet the code requirements given in the 2021 Special Design Provisions for Wind and Seismic (SDPWS) (American Wood Council, 2020). To do so, three configurations with varied inter-panel connections were tested. To identify the impact of different inter-panel fasteners, metal surface splines with nails and screws were evaluated. The metal surface spline along the beam lines was then removed to test the use of the panel-beam connection as the inter-panel connection. Testing revealed an excess in strength capacity with the ASD design strength exceeded by a factor of 4.5-6 across all configurations compared to the required overstrength of 2.8. Due to the large overstrength, the diaphragm can be expected to remain elastic at design forces. Across the ASD design range, the configuration that included metal surface splines with screws had the highest stiffness followed closely by the configuration that relied on the panel-beam connection alone. The metal surface spline configuration with screws had a stiffness double that of the configuration with nails. The three deflection methods included in the investigation were able to more closely predict the diaphragm displacement when the fastener type included was limited to nails. When screws were introduced to the calculation, the deflections had larger overpredictions.","abstract_has_math":false,"creators":["Thomas, Della"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Phillips, Adam Richard"],"committee_members":["Fischer, Erica","Eatherton, Matthew Roy"],"year":2026,"date_issued":"2026-06-23","date_published":"2026-06-23","updated_at":"2026-11-18T20:21:35Z","subjects":["CLT","CLT-Steel Hybrid","CLT Diaphragm","Mass Timber"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:46885"],"render_values":[{"text":"vt_gsexam:46885","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143490","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143490","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143490","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Phillips, Adam Richard"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Fischer, Erica","Eatherton, Matthew Roy"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Thomas, Della"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-06-24T08:00:57Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-06-24T08:00:57Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-06-23"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["CLT","CLT-Steel Hybrid","CLT Diaphragm","Mass Timber"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:46885"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143490"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this investigation is to identify the behavior of wide aspect ratio, cross-laminated timber (CLT) diaphragms, with steel gravity members, designed to meet the code requirements given in the 2021 Special Design Provisions for Wind and Seismic (SDPWS) (American Wood Council, 2020). To do so, three configurations with varied inter-panel connections were tested. To identify the impact of different inter-panel fasteners, metal surface splines with nails and screws were evaluated. The metal surface spline along the beam lines was then removed to test the use of the panel-beam connection as the inter-panel connection. Testing revealed an excess in strength capacity with the ASD design strength exceeded by a factor of 4.5-6 across all configurations compared to the required overstrength of 2.8. Due to the large overstrength, the diaphragm can be expected to remain elastic at design forces. Across the ASD design range, the configuration that included metal surface splines with screws had the highest stiffness followed closely by the configuration that relied on the panel-beam connection alone. The metal surface spline configuration with screws had a stiffness double that of the configuration with nails. The three deflection methods included in the investigation were able to more closely predict the diaphragm displacement when the fastener type included was limited to nails. When screws were introduced to the calculation, the deflections had larger overpredictions."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["There has recently been a rise in the popularity of mass timber, including cross-laminated timber (CLT). CLT consists of wood plies that are stacked in alternating directions and glued together. These CLT panels can be used in conjunction with steel beams and columns to create a CLT-steel hybrid building. The CLT panels make up the floor system and act as the diaphragm. During an earthquake, the diaphragm will act as the start of the load path and will distribute the force into the lateral force resisting system. While these diaphragms are currently being designed and built, there are still questions pertaining to their behavior during an earthquake. In order to identify their behavior, this investigation included the testing of three CLT diaphragm configurations. Testing revealed that each configuration had a strength capacity that well exceeded the expected design strength. Three methods for calculating the deflection of the diaphragm were compared to the experimentally observed deflections. A comparison between the two indicates room for further refinement."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Experimental Tests of Wide Aspect Ratio Cross Laminated Timber – Steel Diaphragms for Hybrid Building Applications"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Phillips, Adam Richard"],"dc:contributor.committeemember":["Fischer, Erica","Eatherton, Matthew Roy"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:creator":["Thomas, Della"],"dc:date.accessioned":["2026-06-24T08:00:57Z"],"dc:date.available":["2026-06-24T08:00:57Z"],"dc:date.issued":["2026-06-23"],"dc:description.abstract":["The purpose of this investigation is to identify the behavior of wide aspect ratio, cross-laminated timber (CLT) diaphragms, with steel gravity members, designed to meet the code requirements given in the 2021 Special Design Provisions for Wind and Seismic (SDPWS) (American Wood Council, 2020). To do so, three configurations with varied inter-panel connections were tested. To identify the impact of different inter-panel fasteners, metal surface splines with nails and screws were evaluated. The metal surface spline along the beam lines was then removed to test the use of the panel-beam connection as the inter-panel connection. Testing revealed an excess in strength capacity with the ASD design strength exceeded by a factor of 4.5-6 across all configurations compared to the required overstrength of 2.8. Due to the large overstrength, the diaphragm can be expected to remain elastic at design forces. Across the ASD design range, the configuration that included metal surface splines with screws had the highest stiffness followed closely by the configuration that relied on the panel-beam connection alone. The metal surface spline configuration with screws had a stiffness double that of the configuration with nails. The three deflection methods included in the investigation were able to more closely predict the diaphragm displacement when the fastener type included was limited to nails. When screws were introduced to the calculation, the deflections had larger overpredictions."],"dc:description.abstractgeneral":["There has recently been a rise in the popularity of mass timber, including cross-laminated timber (CLT). CLT consists of wood plies that are stacked in alternating directions and glued together. These CLT panels can be used in conjunction with steel beams and columns to create a CLT-steel hybrid building. The CLT panels make up the floor system and act as the diaphragm. During an earthquake, the diaphragm will act as the start of the load path and will distribute the force into the lateral force resisting system. While these diaphragms are currently being designed and built, there are still questions pertaining to their behavior during an earthquake. In order to identify their behavior, this investigation included the testing of three CLT diaphragm configurations. Testing revealed that each configuration had a strength capacity that well exceeded the expected design strength. Three methods for calculating the deflection of the diaphragm were compared to the experimentally observed deflections. A comparison between the two indicates room for further refinement."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:46885"],"dc:identifier.uri":["https://hdl.handle.net/10919/143490"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["CLT","CLT-Steel Hybrid","CLT Diaphragm","Mass Timber"],"dc:title":["Experimental Tests of Wide Aspect Ratio Cross Laminated Timber – Steel Diaphragms for Hybrid Building Applications"],"dc:type":["Thesis"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:21:35Z"}