{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143558"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143558","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Computational Modeling of Hollow-Fiber Hemodialyzers (Artificial Kidneys)","abstract":"Hollow-fiber hemodialyzers are widely used medical devices for removing uremic toxins from blood. Despite their introduction in the 1960s, their design has seen limited advancement, and several performance limitations remain unresolved. Computational modeling offers a powerful alternative to experimental approaches by enabling rapid exploration of device design, dialysis dose, and operating conditions while reducing time and cost. This dissertation first reviews existing models of dialyzer hydrodynamics, broadly categorizing them into heterogeneous (single-fiber resolved) and pseudo-homogeneous (porous media) approaches, and highlights restrictive assumptions that may limit predictive accuracy. Existing approaches for estimating dialysate-side permeability rely on single-fiber theories, semi-empirical packed-bed correlations, or hydraulic resistance experiments. In this work, permeability is computed directly by resolving flow through the complex shell-side geometry containing 10⁴ fibers, using three-dimensional Navier–Stokes simulations. Analysis across twenty dialyzer modules yields a generalized relationship between pressure drop and flow rate, formulated here as a Modified Ergun Equation. Building on this framework, a sustainability-oriented performance metric—clearance per pumping power—is introduced to quantify the trade-off between solute removal and hydraulic energy consumption and to identify water- and energy-efficient operating conditions. In addition, a multiscale modeling framework is developed to predict solute clearance by coupling porous media descriptions with resolved free-flow regions around fibers. Finally, a multifiber model is proposed, enabling prediction of dialyzer clearance using only a limited number of representative fibers.","abstract_html":"Hollow-fiber hemodialyzers are widely used medical devices for removing uremic toxins from blood. Despite their introduction in the 1960s, their design has seen limited advancement, and several performance limitations remain unresolved. Computational modeling offers a powerful alternative to experimental approaches by enabling rapid exploration of device design, dialysis dose, and operating conditions while reducing time and cost. This dissertation first reviews existing models of dialyzer hydrodynamics, broadly categorizing them into heterogeneous (single-fiber resolved) and pseudo-homogeneous (porous media) approaches, and highlights restrictive assumptions that may limit predictive accuracy. Existing approaches for estimating dialysate-side permeability rely on single-fiber theories, semi-empirical packed-bed correlations, or hydraulic resistance experiments. In this work, permeability is computed directly by resolving flow through the complex shell-side geometry containing 10⁴ fibers, using three-dimensional Navier–Stokes simulations. Analysis across twenty dialyzer modules yields a generalized relationship between pressure drop and flow rate, formulated here as a Modified Ergun Equation. Building on this framework, a sustainability-oriented performance metric—clearance per pumping power—is introduced to quantify the trade-off between solute removal and hydraulic energy consumption and to identify water- and energy-efficient operating conditions. In addition, a multiscale modeling framework is developed to predict solute clearance by coupling porous media descriptions with resolved free-flow regions around fibers. Finally, a multifiber model is proposed, enabling prediction of dialyzer clearance using only a limited number of representative fibers.","abstract_has_math":false,"creators":["Sinha, Ruhit"],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Engineering Mechanics","degree_department":"Engineering Science and Mechanics","school":null,"contributors":[],"advisors":[],"committee_chairs":["Staples, Anne E."],"committee_members":["Robertson, John L.","Kale, Sohan","Tafti, Danesh K.","Rocco, Michael"],"year":2026,"date_issued":"2026-07-02","date_published":"2026-07-02","updated_at":"2026-11-18T20:08:41Z","subjects":["Hollow-fiber membrane module","dialysis","porous media","multifiber","multiscale","clearance"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47246"],"render_values":[{"text":"vt_gsexam:47246","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143558","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143558","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143558","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Staples, Anne E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Robertson, John L.","Kale, Sohan","Tafti, Danesh K.","Rocco, Michael"]},{"key":"dc:contributor.department","label":"Department","values":["Engineering Science and Mechanics"]},{"key":"dc:creator","label":"Author","values":["Sinha, Ruhit"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-03T08:00:18Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-03T08:00:18Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-07-02"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Mechanics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hollow-fiber membrane module","dialysis","porous media","multifiber","multiscale","clearance"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47246"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143558"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Hollow-fiber hemodialyzers are widely used medical devices for removing uremic toxins from blood. Despite their introduction in the 1960s, their design has seen limited advancement, and several performance limitations remain unresolved. Computational modeling offers a powerful alternative to experimental approaches by enabling rapid exploration of device design, dialysis dose, and operating conditions while reducing time and cost. This dissertation first reviews existing models of dialyzer hydrodynamics, broadly categorizing them into heterogeneous (single-fiber resolved) and pseudo-homogeneous (porous media) approaches, and highlights restrictive assumptions that may limit predictive accuracy. Existing approaches for estimating dialysate-side permeability rely on single-fiber theories, semi-empirical packed-bed correlations, or hydraulic resistance experiments. In this work, permeability is computed directly by resolving flow through the complex shell-side geometry containing 10⁴ fibers, using three-dimensional Navier–Stokes simulations. Analysis across twenty dialyzer modules yields a generalized relationship between pressure drop and flow rate, formulated here as a Modified Ergun Equation. Building on this framework, a sustainability-oriented performance metric—clearance per pumping power—is introduced to quantify the trade-off between solute removal and hydraulic energy consumption and to identify water- and energy-efficient operating conditions. In addition, a multiscale modeling framework is developed to predict solute clearance by coupling porous media descriptions with resolved free-flow regions around fibers. Finally, a multifiber model is proposed, enabling prediction of dialyzer clearance using only a limited number of representative fibers."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Hollow-fiber hemodialyzers are medical devices used to clean waste products from the blood of patients with kidney failure. Although this technology has been in use since the 1960s, its design has changed little, and important limitations remain. Computer-based modeling offers a faster and more cost-effective way to improve these devices by allowing researchers to test new designs and operating conditions without relying entirely on laboratory experiments. This work first reviews existing approaches used to model how fluid flows inside a dialyzer and shows that many of them depend on simplifying assumptions that limit their accuracy. Current methods for predicting how easily fluid moves through the device rely on simplified theories or experimental data. In this study, we instead simulate fluid flow in realistic dialyzer geometries containing thousands of fibers using advanced computational methods. From these simulations, we develop a new relationship that more accurately predicts how pressure and flow are related inside the device. Using this improved understanding, we introduce a new way to measure dialyzer performance that considers not only how well the device removes toxins, but also how much energy is required to operate it. This allows us to identify operating conditions that can reduce both energy required to pump the fluids and dialysate (water) consumption. We also develop new modeling approaches that combine detailed and simplified representations of flow, making it possible to predict device performance more efficiently. Finally, we introduce a reduced model that can accurately estimate dialyzer performance using only a small number of fibers, significantly lowering computational cost."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Computational Modeling of Hollow-Fiber Hemodialyzers (Artificial Kidneys)"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Staples, Anne E."],"dc:contributor.committeemember":["Robertson, John L.","Kale, Sohan","Tafti, Danesh K.","Rocco, Michael"],"dc:contributor.department":["Engineering Science and Mechanics"],"dc:creator":["Sinha, Ruhit"],"dc:date.accessioned":["2026-07-03T08:00:18Z"],"dc:date.available":["2026-07-03T08:00:18Z"],"dc:date.issued":["2026-07-02"],"dc:description.abstract":["Hollow-fiber hemodialyzers are widely used medical devices for removing uremic toxins from blood. Despite their introduction in the 1960s, their design has seen limited advancement, and several performance limitations remain unresolved. Computational modeling offers a powerful alternative to experimental approaches by enabling rapid exploration of device design, dialysis dose, and operating conditions while reducing time and cost. This dissertation first reviews existing models of dialyzer hydrodynamics, broadly categorizing them into heterogeneous (single-fiber resolved) and pseudo-homogeneous (porous media) approaches, and highlights restrictive assumptions that may limit predictive accuracy. Existing approaches for estimating dialysate-side permeability rely on single-fiber theories, semi-empirical packed-bed correlations, or hydraulic resistance experiments. In this work, permeability is computed directly by resolving flow through the complex shell-side geometry containing 10⁴ fibers, using three-dimensional Navier–Stokes simulations. Analysis across twenty dialyzer modules yields a generalized relationship between pressure drop and flow rate, formulated here as a Modified Ergun Equation. Building on this framework, a sustainability-oriented performance metric—clearance per pumping power—is introduced to quantify the trade-off between solute removal and hydraulic energy consumption and to identify water- and energy-efficient operating conditions. In addition, a multiscale modeling framework is developed to predict solute clearance by coupling porous media descriptions with resolved free-flow regions around fibers. Finally, a multifiber model is proposed, enabling prediction of dialyzer clearance using only a limited number of representative fibers."],"dc:description.abstractgeneral":["Hollow-fiber hemodialyzers are medical devices used to clean waste products from the blood of patients with kidney failure. Although this technology has been in use since the 1960s, its design has changed little, and important limitations remain. Computer-based modeling offers a faster and more cost-effective way to improve these devices by allowing researchers to test new designs and operating conditions without relying entirely on laboratory experiments. This work first reviews existing approaches used to model how fluid flows inside a dialyzer and shows that many of them depend on simplifying assumptions that limit their accuracy. Current methods for predicting how easily fluid moves through the device rely on simplified theories or experimental data. In this study, we instead simulate fluid flow in realistic dialyzer geometries containing thousands of fibers using advanced computational methods. From these simulations, we develop a new relationship that more accurately predicts how pressure and flow are related inside the device. Using this improved understanding, we introduce a new way to measure dialyzer performance that considers not only how well the device removes toxins, but also how much energy is required to operate it. This allows us to identify operating conditions that can reduce both energy required to pump the fluids and dialysate (water) consumption. We also develop new modeling approaches that combine detailed and simplified representations of flow, making it possible to predict device performance more efficiently. Finally, we introduce a reduced model that can accurately estimate dialyzer performance using only a small number of fibers, significantly lowering computational cost."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:47246"],"dc:identifier.uri":["https://hdl.handle.net/10919/143558"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Hollow-fiber membrane module","dialysis","porous media","multifiber","multiscale","clearance"],"dc:title":["Computational Modeling of Hollow-Fiber Hemodialyzers (Artificial Kidneys)"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Engineering Mechanics"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:08:41Z"}