{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143633"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143633","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Characterization, Evaluation, and Design of Broadband Current Transducers for High-Frequency EMI Diagnosis in Power Converters","abstract":"This thesis investigates the design, calibration, and evaluation of a broadband current transducer for high-frequency EMI diagnosis in power converters. Existing voltage-based and current-based methods are first analyzed, and their main limitations in bandwidth, repeatability, loading effect, and calibration accuracy are identified. On this basis, a single-turn broadband current probe is developed for cable-conducted noise current measurement up to 1 GHz. A dedicated calibration method is then established using a current-probe fixture modeled as a piecewise transmission-line structure. Through TDR-based parameter extraction, the fixture behavior is characterized, and a complete error-propagation derivation is presented to quantitatively estimate the resulting calibration and measurement uncertainty. The influences of fixture nonuniformity, probe placement, external coupling, and loading effect are evaluated systematically. Experimental results verify that the proposed probe achieves broadband operation, improved repeatability, effective shielding performance, and acceptable loading effect. The developed method provides a practical and reliable tool for high-frequency EMI diagnosis in power converters.","abstract_html":"This thesis investigates the design, calibration, and evaluation of a broadband current transducer for high-frequency EMI diagnosis in power converters. Existing voltage-based and current-based methods are first analyzed, and their main limitations in bandwidth, repeatability, loading effect, and calibration accuracy are identified. On this basis, a single-turn broadband current probe is developed for cable-conducted noise current measurement up to 1 GHz. A dedicated calibration method is then established using a current-probe fixture modeled as a piecewise transmission-line structure. Through TDR-based parameter extraction, the fixture behavior is characterized, and a complete error-propagation derivation is presented to quantitatively estimate the resulting calibration and measurement uncertainty. The influences of fixture nonuniformity, probe placement, external coupling, and loading effect are evaluated systematically. Experimental results verify that the proposed probe achieves broadband operation, improved repeatability, effective shielding performance, and acceptable loading effect. The developed method provides a practical and reliable tool for high-frequency EMI diagnosis in power converters.","abstract_has_math":false,"creators":["Li, Xiang"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical and Computer Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Li, Qiang"],"committee_members":["Zhu, Liyan","DiMarino, Christina M."],"year":2026,"date_issued":"2026-04-30","date_published":"2026-04-30","updated_at":"2026-11-18T20:09:16Z","subjects":["Electromagnetic Interference","Switch-Mode Power Supply","Current Transducer","Cable Conducted Noise Current"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143633","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143633","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143633","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Li, Qiang"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Zhu, Liyan","DiMarino, Christina M."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical and Computer Engineering"]},{"key":"dc:creator","label":"Author","values":["Li, Xiang"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-10T19:49:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-10T19:49:55Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-04-30"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Electromagnetic Interference","Switch-Mode Power Supply","Current Transducer","Cable Conducted Noise Current"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143633"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis investigates the design, calibration, and evaluation of a broadband current transducer for high-frequency EMI diagnosis in power converters. Existing voltage-based and current-based methods are first analyzed, and their main limitations in bandwidth, repeatability, loading effect, and calibration accuracy are identified. On this basis, a single-turn broadband current probe is developed for cable-conducted noise current measurement up to 1 GHz. A dedicated calibration method is then established using a current-probe fixture modeled as a piecewise transmission-line structure. Through TDR-based parameter extraction, the fixture behavior is characterized, and a complete error-propagation derivation is presented to quantitatively estimate the resulting calibration and measurement uncertainty. The influences of fixture nonuniformity, probe placement, external coupling, and loading effect are evaluated systematically. Experimental results verify that the proposed probe achieves broadband operation, improved repeatability, effective shielding performance, and acceptable loading effect. The developed method provides a practical and reliable tool for high-frequency EMI diagnosis in power converters."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Power converters can generate unwanted electromagnetic noise that interferes with nearby electronic systems. One important source of this interference is the high-frequency noise current flowing on connected cables. Measuring this current accurately is helpful for diagnosing EMI problems before formal compliance testing. This thesis develops a broadband current probe for measuring high-frequency cable noise in power converters. It also proposes a dedicated calibration method to improve measurement accuracy. A key contribution is the complete derivation of the error-propagation process and the quantitative estimation of measurement uncertainty. Experiments show that the proposed probe provides wide bandwidth, good repeatability, effective shielding, and acceptable measurement disturbance. The results offer a practical tool for EMI diagnosis in high-frequency power electronic systems."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Characterization, Evaluation, and Design of Broadband Current Transducers for High-Frequency EMI Diagnosis in Power Converters"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Li, Qiang"],"dc:contributor.committeemember":["Zhu, Liyan","DiMarino, Christina M."],"dc:contributor.department":["Electrical and Computer Engineering"],"dc:creator":["Li, Xiang"],"dc:date.accessioned":["2026-07-10T19:49:55Z"],"dc:date.available":["2026-07-10T19:49:55Z"],"dc:date.issued":["2026-04-30"],"dc:description.abstract":["This thesis investigates the design, calibration, and evaluation of a broadband current transducer for high-frequency EMI diagnosis in power converters. Existing voltage-based and current-based methods are first analyzed, and their main limitations in bandwidth, repeatability, loading effect, and calibration accuracy are identified. On this basis, a single-turn broadband current probe is developed for cable-conducted noise current measurement up to 1 GHz. A dedicated calibration method is then established using a current-probe fixture modeled as a piecewise transmission-line structure. Through TDR-based parameter extraction, the fixture behavior is characterized, and a complete error-propagation derivation is presented to quantitatively estimate the resulting calibration and measurement uncertainty. The influences of fixture nonuniformity, probe placement, external coupling, and loading effect are evaluated systematically. Experimental results verify that the proposed probe achieves broadband operation, improved repeatability, effective shielding performance, and acceptable loading effect. The developed method provides a practical and reliable tool for high-frequency EMI diagnosis in power converters."],"dc:description.abstractgeneral":["Power converters can generate unwanted electromagnetic noise that interferes with nearby electronic systems. One important source of this interference is the high-frequency noise current flowing on connected cables. Measuring this current accurately is helpful for diagnosing EMI problems before formal compliance testing. This thesis develops a broadband current probe for measuring high-frequency cable noise in power converters. It also proposes a dedicated calibration method to improve measurement accuracy. A key contribution is the complete derivation of the error-propagation process and the quantitative estimation of measurement uncertainty. Experiments show that the proposed probe provides wide bandwidth, good repeatability, effective shielding, and acceptable measurement disturbance. The results offer a practical tool for EMI diagnosis in high-frequency power electronic systems."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10919/143633"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Electromagnetic Interference","Switch-Mode Power Supply","Current Transducer","Cable Conducted Noise Current"],"dc:title":["Characterization, Evaluation, and Design of Broadband Current Transducers for High-Frequency EMI Diagnosis in Power Converters"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:09:16Z"}