{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143713"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143713","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Application of Foam Fractionation Technology for the Removal of Disinfection Byproduct Precursors: Challenges and Opportunities","abstract":"Foam fractionation is a cost-effective physicochemical process that concentrates surface-active compounds at the air-water interface and is recognized for its effectiveness in removing per- and polyfluoroalkyl substances (PFAS) from different aqueous matrices. To this date, evaluation of simultaneous control of disinfection byproduct (DBP) formation in drinking water and potable reuse systems through foam fractionation had not been investigated. This thesis evaluated the removal of DBP precursors using a bench-scale foam fractionation system assisted by cetyltrimethylammonium bromide (CTAB), analyzing surrogate solutions and water samples from the Occoquan Reservoir, an indirect potable reuse source, at pH levels between 6.5-8.5. Foam fractionation experiments demonstrated high removal efficiencies for the carbonaceous surrogate (humic acid; 80-96%, average 88.7%) and the nitrogenous surrogate (L-tryptophan; 80-99%, average 92.4%). In the real water matrix, post-fractionation decreased dissolved organic carbon by 35%, UV absorbance and specific UV absorbance at 254 nm by 78% and 65%, respectively, indicating effective removal of aromatic and hydrophobic natural organic matter. Following chlorination, regulated trihalomethane formation fell 88-97% and haloacetic acids by 60-82% at pH 6.5-7.0; haloketones, haloacetaldehydes, and trichloronitromethane were near-completely suppressed in the post-treatment. In the treated water, toxicity-weighted responses increased by 58-110% across all pH levels, attributed to a shift towards brominated species incorporation from CTAB-derived bromide. At the lowest CTAB dosing tested, toxicity-weighted response declined to approximately 1%, whereas the bromine substitution factor plateaued at 30-40% of untreated levels. Bromine substitution therefore persisted at bromide concentrations well below those associated with the full CTAB dose, indicating that reducing bromide loading alone did not remove it under the tested CTAB removal conditions. These findings show that foam fractionation can effectively reduce the downstream DBP formation potential, while emphasizing the importance of careful surfactant selection and further optimization in engineering design for achieving public health goals in drinking water treatment context.","abstract_html":"Foam fractionation is a cost-effective physicochemical process that concentrates surface-active compounds at the air-water interface and is recognized for its effectiveness in removing per- and polyfluoroalkyl substances (PFAS) from different aqueous matrices. To this date, evaluation of simultaneous control of disinfection byproduct (DBP) formation in drinking water and potable reuse systems through foam fractionation had not been investigated. This thesis evaluated the removal of DBP precursors using a bench-scale foam fractionation system assisted by cetyltrimethylammonium bromide (CTAB), analyzing surrogate solutions and water samples from the Occoquan Reservoir, an indirect potable reuse source, at pH levels between 6.5-8.5. Foam fractionation experiments demonstrated high removal efficiencies for the carbonaceous surrogate (humic acid; 80-96%, average 88.7%) and the nitrogenous surrogate (L-tryptophan; 80-99%, average 92.4%). In the real water matrix, post-fractionation decreased dissolved organic carbon by 35%, UV absorbance and specific UV absorbance at 254 nm by 78% and 65%, respectively, indicating effective removal of aromatic and hydrophobic natural organic matter. Following chlorination, regulated trihalomethane formation fell 88-97% and haloacetic acids by 60-82% at pH 6.5-7.0; haloketones, haloacetaldehydes, and trichloronitromethane were near-completely suppressed in the post-treatment. In the treated water, toxicity-weighted responses increased by 58-110% across all pH levels, attributed to a shift towards brominated species incorporation from CTAB-derived bromide. At the lowest CTAB dosing tested, toxicity-weighted response declined to approximately 1%, whereas the bromine substitution factor plateaued at 30-40% of untreated levels. Bromine substitution therefore persisted at bromide concentrations well below those associated with the full CTAB dose, indicating that reducing bromide loading alone did not remove it under the tested CTAB removal conditions. These findings show that foam fractionation can effectively reduce the downstream DBP formation potential, while emphasizing the importance of careful surfactant selection and further optimization in engineering design for achieving public health goals in drinking water treatment context.","abstract_has_math":false,"creators":["Haque, Md Sazzadul"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil and Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Furst, Kirin"],"committee_members":["Maizel, Andrew","Wilson, Christopher"],"year":2026,"date_issued":"2026-07-30","date_published":"2026-07-30","updated_at":"2026-11-18T20:16:49Z","subjects":["Foam fractionation","disinfection byproducts","PFAS","contaminants of emerging concern","natural organic matter","drinking water","water reuse"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143713","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143713","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143713","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Furst, Kirin"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Maizel, Andrew","Wilson, Christopher"]},{"key":"dc:contributor.department","label":"Department","values":["Civil and Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Haque, Md Sazzadul"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-08-12T17:37:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-08-12T17:37:35Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-07-30"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Foam fractionation","disinfection byproducts","PFAS","contaminants of emerging concern","natural organic matter","drinking water","water reuse"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143713"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Foam fractionation is a cost-effective physicochemical process that concentrates surface-active compounds at the air-water interface and is recognized for its effectiveness in removing per- and polyfluoroalkyl substances (PFAS) from different aqueous matrices. To this date, evaluation of simultaneous control of disinfection byproduct (DBP) formation in drinking water and potable reuse systems through foam fractionation had not been investigated. This thesis evaluated the removal of DBP precursors using a bench-scale foam fractionation system assisted by cetyltrimethylammonium bromide (CTAB), analyzing surrogate solutions and water samples from the Occoquan Reservoir, an indirect potable reuse source, at pH levels between 6.5-8.5. Foam fractionation experiments demonstrated high removal efficiencies for the carbonaceous surrogate (humic acid; 80-96%, average 88.7%) and the nitrogenous surrogate (L-tryptophan; 80-99%, average 92.4%). In the real water matrix, post-fractionation decreased dissolved organic carbon by 35%, UV absorbance and specific UV absorbance at 254 nm by 78% and 65%, respectively, indicating effective removal of aromatic and hydrophobic natural organic matter. Following chlorination, regulated trihalomethane formation fell 88-97% and haloacetic acids by 60-82% at pH 6.5-7.0; haloketones, haloacetaldehydes, and trichloronitromethane were near-completely suppressed in the post-treatment. In the treated water, toxicity-weighted responses increased by 58-110% across all pH levels, attributed to a shift towards brominated species incorporation from CTAB-derived bromide. At the lowest CTAB dosing tested, toxicity-weighted response declined to approximately 1%, whereas the bromine substitution factor plateaued at 30-40% of untreated levels. Bromine substitution therefore persisted at bromide concentrations well below those associated with the full CTAB dose, indicating that reducing bromide loading alone did not remove it under the tested CTAB removal conditions. These findings show that foam fractionation can effectively reduce the downstream DBP formation potential, while emphasizing the importance of careful surfactant selection and further optimization in engineering design for achieving public health goals in drinking water treatment context."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Disinfecting drinking water is essential to protect the public health from harmful microorganisms, with chlorine being the most common disinfectant worldwide. However, chlorine can react with organic compounds present in source water, leading to the formation of unwanted, harmful disinfection byproducts (DBPs) that may pose long-term health risks, such as increased cancer risk and reproductive harm, even at very low concentrations. The most effective strategy to reduce these reactive organic compounds is through precursor removal process, achieved by removing these compounds before chlorine is added to the water. This study explored foam fractionation as a cost-effective technique to do this process. Thorough this process, fine air bubbles are supplied in a water column, leading to the accumulation of organic compounds from water in the produced foam at the top, which can then be manually skimmed off. The process is used in aquariums for maintaining clean water and is also being investigated for its potential to remove forever chemicals (i.e., PFAS) from contaminated water supplies. This study investigated foam fractionation's ability to reduce harmful disinfection byproducts. Laboratory experiments with reservoir water from the Occoquan watershed in northern Virginia showed promising results, successfully removing up to 97% of organic matter responsible for formation of these byproducts. The chemical, cetyltrimethylammonium bromide, used for generating foam, contains bromine, which was released into the water and after chlorination, formed more toxic byproducts. Despite a significant decrease in the total quantity of disinfection byproducts, the overall toxicity of the mixture increased. Simulation results indicated that removing around 90-99% of the foaming chemical reduces toxicity but does not fully eliminate the bromine effect. The key takeaway is that foam fractionation is a promising treatment method for improving drinking water safety, especially for managing PFAS and disinfection byproducts. However, using a bromine-free foaming agent is crucial to prevent the unintentional, high toxicity-levels in the finished water."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Application of Foam Fractionation Technology for the Removal of Disinfection Byproduct Precursors: Challenges and Opportunities"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Furst, Kirin"],"dc:contributor.committeemember":["Maizel, Andrew","Wilson, Christopher"],"dc:contributor.department":["Civil and Environmental Engineering"],"dc:creator":["Haque, Md Sazzadul"],"dc:date.accessioned":["2026-08-12T17:37:35Z"],"dc:date.available":["2026-08-12T17:37:35Z"],"dc:date.issued":["2026-07-30"],"dc:description.abstract":["Foam fractionation is a cost-effective physicochemical process that concentrates surface-active compounds at the air-water interface and is recognized for its effectiveness in removing per- and polyfluoroalkyl substances (PFAS) from different aqueous matrices. To this date, evaluation of simultaneous control of disinfection byproduct (DBP) formation in drinking water and potable reuse systems through foam fractionation had not been investigated. This thesis evaluated the removal of DBP precursors using a bench-scale foam fractionation system assisted by cetyltrimethylammonium bromide (CTAB), analyzing surrogate solutions and water samples from the Occoquan Reservoir, an indirect potable reuse source, at pH levels between 6.5-8.5. Foam fractionation experiments demonstrated high removal efficiencies for the carbonaceous surrogate (humic acid; 80-96%, average 88.7%) and the nitrogenous surrogate (L-tryptophan; 80-99%, average 92.4%). In the real water matrix, post-fractionation decreased dissolved organic carbon by 35%, UV absorbance and specific UV absorbance at 254 nm by 78% and 65%, respectively, indicating effective removal of aromatic and hydrophobic natural organic matter. Following chlorination, regulated trihalomethane formation fell 88-97% and haloacetic acids by 60-82% at pH 6.5-7.0; haloketones, haloacetaldehydes, and trichloronitromethane were near-completely suppressed in the post-treatment. In the treated water, toxicity-weighted responses increased by 58-110% across all pH levels, attributed to a shift towards brominated species incorporation from CTAB-derived bromide. At the lowest CTAB dosing tested, toxicity-weighted response declined to approximately 1%, whereas the bromine substitution factor plateaued at 30-40% of untreated levels. Bromine substitution therefore persisted at bromide concentrations well below those associated with the full CTAB dose, indicating that reducing bromide loading alone did not remove it under the tested CTAB removal conditions. These findings show that foam fractionation can effectively reduce the downstream DBP formation potential, while emphasizing the importance of careful surfactant selection and further optimization in engineering design for achieving public health goals in drinking water treatment context."],"dc:description.abstractgeneral":["Disinfecting drinking water is essential to protect the public health from harmful microorganisms, with chlorine being the most common disinfectant worldwide. However, chlorine can react with organic compounds present in source water, leading to the formation of unwanted, harmful disinfection byproducts (DBPs) that may pose long-term health risks, such as increased cancer risk and reproductive harm, even at very low concentrations. The most effective strategy to reduce these reactive organic compounds is through precursor removal process, achieved by removing these compounds before chlorine is added to the water. This study explored foam fractionation as a cost-effective technique to do this process. Thorough this process, fine air bubbles are supplied in a water column, leading to the accumulation of organic compounds from water in the produced foam at the top, which can then be manually skimmed off. The process is used in aquariums for maintaining clean water and is also being investigated for its potential to remove forever chemicals (i.e., PFAS) from contaminated water supplies. This study investigated foam fractionation's ability to reduce harmful disinfection byproducts. Laboratory experiments with reservoir water from the Occoquan watershed in northern Virginia showed promising results, successfully removing up to 97% of organic matter responsible for formation of these byproducts. The chemical, cetyltrimethylammonium bromide, used for generating foam, contains bromine, which was released into the water and after chlorination, formed more toxic byproducts. Despite a significant decrease in the total quantity of disinfection byproducts, the overall toxicity of the mixture increased. Simulation results indicated that removing around 90-99% of the foaming chemical reduces toxicity but does not fully eliminate the bromine effect. The key takeaway is that foam fractionation is a promising treatment method for improving drinking water safety, especially for managing PFAS and disinfection byproducts. However, using a bromine-free foaming agent is crucial to prevent the unintentional, high toxicity-levels in the finished water."],"dc:description.degree":["Master of Science"],"dc:format.medium":["ETD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.uri":["https://hdl.handle.net/10919/143713"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Foam fractionation","disinfection byproducts","PFAS","contaminants of emerging concern","natural organic matter","drinking water","water reuse"],"dc:title":["Application of Foam Fractionation Technology for the Removal of Disinfection Byproduct Precursors: Challenges and Opportunities"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:16:49Z"}