{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143801"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143801","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Human Auditory Perception and Performance Across Air- and Bone-Conduction Listening Pathways","abstract":"Auditory displays support communication, monitoring, and decision-making when visual attention is limited or divided. Most systems use air-conducted (AC) presentation, whereas bone-conducted (BC) presentation delivers vibration through the skull and surrounding tissues while leaving the ear canal open. This open-ear configuration may be useful when users must monitor environmental sound, wear hearing protection, or receive device-mediated audio from more than one source. Three linked gaps remain: performance through AC alone, performance through BC alone, and, most importantly, whether simultaneous AC+BC presentation provides additional usable auditory capacity. This dissertation addressed those gaps in three within-subjects experiments with untrained participants. Study 1 tested whether participants could identify the presentation mode (AC or BC) and channel (left or right) of tones and noises after subjective reference-tone loudness balancing. Study 2 tested whether simultaneous AC+BC presentation increased the number of signals or spatial locations participants could enumerate and discriminate. Study 3 tested whether AC and BC alerts supported identification and response performance during visual-motor multitasking. Study 1 showed that attribution depended jointly on mode and signal type: BC produced higher accuracy at 250 Hz, whereas AC produced higher accuracy for most mid- to high-frequency tones and white noise. Study 2 showed selected BC advantages for tone-count and spatial-count judgments, but simultaneous AC+BC presentation did not produce a statistically reliable increase in enumeration capacity or spatial discrimination. Study 3 showed higher overall alert-identification accuracy for AC, with mode-specific differences concentrated in broadband alerts. Whether a hybrid AC/BC auditory display is beneficial depends on how information is encoded, what participants must discriminate, and the demands of the concurrent task. Overall, hybrid AC/BC displays should be applied selectively. The presentation mode, signal characteristics, and task requirements must be matched rather than assuming that BC or simultaneous AC+BC presentation will improve performance. These results provide design guidance for operational, assistive, and multitask auditory displays.","abstract_html":"Auditory displays support communication, monitoring, and decision-making when visual attention is limited or divided. Most systems use air-conducted (AC) presentation, whereas bone-conducted (BC) presentation delivers vibration through the skull and surrounding tissues while leaving the ear canal open. This open-ear configuration may be useful when users must monitor environmental sound, wear hearing protection, or receive device-mediated audio from more than one source. Three linked gaps remain: performance through AC alone, performance through BC alone, and, most importantly, whether simultaneous AC+BC presentation provides additional usable auditory capacity. This dissertation addressed those gaps in three within-subjects experiments with untrained participants. Study 1 tested whether participants could identify the presentation mode (AC or BC) and channel (left or right) of tones and noises after subjective reference-tone loudness balancing. Study 2 tested whether simultaneous AC+BC presentation increased the number of signals or spatial locations participants could enumerate and discriminate. Study 3 tested whether AC and BC alerts supported identification and response performance during visual-motor multitasking. Study 1 showed that attribution depended jointly on mode and signal type: BC produced higher accuracy at 250 Hz, whereas AC produced higher accuracy for most mid- to high-frequency tones and white noise. Study 2 showed selected BC advantages for tone-count and spatial-count judgments, but simultaneous AC+BC presentation did not produce a statistically reliable increase in enumeration capacity or spatial discrimination. Study 3 showed higher overall alert-identification accuracy for AC, with mode-specific differences concentrated in broadband alerts. Whether a hybrid AC/BC auditory display is beneficial depends on how information is encoded, what participants must discriminate, and the demands of the concurrent task. Overall, hybrid AC/BC displays should be applied selectively. The presentation mode, signal characteristics, and task requirements must be matched rather than assuming that BC or simultaneous AC+BC presentation will improve performance. These results provide design guidance for operational, assistive, and multitask auditory displays.","abstract_has_math":false,"creators":["Currie, Levern Queen"],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Industrial and Systems Engineering","degree_department":"Industrial and Systems Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Patrick, Rafael","Lau, Nathan Ka Ching"],"committee_members":["Madigan, Michael L.","Folds, Dennis J."],"year":2026,"date_issued":"2026-09-09","date_published":"2026-09-09","updated_at":"2026-11-18T20:17:29Z","subjects":["Signal Detection Theory","Auditory Localization","Divided Attention","Hybrid Auditory Display","Human Factors"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47593"],"render_values":[{"text":"vt_gsexam:47593","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143801","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143801","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143801","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Patrick, Rafael","Lau, Nathan Ka Ching"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Madigan, Michael L.","Folds, Dennis J."]},{"key":"dc:contributor.department","label":"Department","values":["Industrial and Systems Engineering"]},{"key":"dc:creator","label":"Author","values":["Currie, Levern Queen"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-10T08:00:41Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-10T08:00:41Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09-09"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Signal Detection Theory","Auditory Localization","Divided Attention","Hybrid Auditory Display","Human Factors"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47593"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143801"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Auditory displays support communication, monitoring, and decision-making when visual attention is limited or divided. Most systems use air-conducted (AC) presentation, whereas bone-conducted (BC) presentation delivers vibration through the skull and surrounding tissues while leaving the ear canal open. This open-ear configuration may be useful when users must monitor environmental sound, wear hearing protection, or receive device-mediated audio from more than one source. Three linked gaps remain: performance through AC alone, performance through BC alone, and, most importantly, whether simultaneous AC+BC presentation provides additional usable auditory capacity. This dissertation addressed those gaps in three within-subjects experiments with untrained participants. Study 1 tested whether participants could identify the presentation mode (AC or BC) and channel (left or right) of tones and noises after subjective reference-tone loudness balancing. Study 2 tested whether simultaneous AC+BC presentation increased the number of signals or spatial locations participants could enumerate and discriminate. Study 3 tested whether AC and BC alerts supported identification and response performance during visual-motor multitasking. Study 1 showed that attribution depended jointly on mode and signal type: BC produced higher accuracy at 250 Hz, whereas AC produced higher accuracy for most mid- to high-frequency tones and white noise. Study 2 showed selected BC advantages for tone-count and spatial-count judgments, but simultaneous AC+BC presentation did not produce a statistically reliable increase in enumeration capacity or spatial discrimination. Study 3 showed higher overall alert-identification accuracy for AC, with mode-specific differences concentrated in broadband alerts. Whether a hybrid AC/BC auditory display is beneficial depends on how information is encoded, what participants must discriminate, and the demands of the concurrent task. Overall, hybrid AC/BC displays should be applied selectively. The presentation mode, signal characteristics, and task requirements must be matched rather than assuming that BC or simultaneous AC+BC presentation will improve performance. These results provide design guidance for operational, assistive, and multitask auditory displays."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["People often rely on sound when they cannot direct their eyes toward an information source, for example while driving, operating equipment, or working in a busy environment. Most sound-based displays send audio through the air to the ears. Bone conduction uses a transducer to deliver vibration through the skull and surrounding tissues, providing another route to the inner ear while leaving the ear canal open. The open ear can maintain access to environmental sound, although device-mediated bone-conducted audio can still interfere with perception of the surrounding environment. This dissertation examined how people perceive and respond to information sent through air and bone conduction, both separately and simultaneously. Across three studies, air-conducted signals were generally identified more accurately. Bone-conducted presentation produced higher accuracy only for specific low-frequency identification and enumeration tasks. Presenting information through both pathways at the same time did not reliably increase the amount of auditory information people could use. The findings show that these systems work best when the presentation pathway and signal characteristics are matched to the task. The results provide practical guidance for sound-based displays used in work, assistive, and multitasking environments."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Human Auditory Perception and Performance Across Air- and Bone-Conduction Listening Pathways"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Patrick, Rafael","Lau, Nathan Ka Ching"],"dc:contributor.committeemember":["Madigan, Michael L.","Folds, Dennis J."],"dc:contributor.department":["Industrial and Systems Engineering"],"dc:creator":["Currie, Levern Queen"],"dc:date.accessioned":["2026-09-10T08:00:41Z"],"dc:date.available":["2026-09-10T08:00:41Z"],"dc:date.issued":["2026-09-09"],"dc:description.abstract":["Auditory displays support communication, monitoring, and decision-making when visual attention is limited or divided. Most systems use air-conducted (AC) presentation, whereas bone-conducted (BC) presentation delivers vibration through the skull and surrounding tissues while leaving the ear canal open. This open-ear configuration may be useful when users must monitor environmental sound, wear hearing protection, or receive device-mediated audio from more than one source. Three linked gaps remain: performance through AC alone, performance through BC alone, and, most importantly, whether simultaneous AC+BC presentation provides additional usable auditory capacity. This dissertation addressed those gaps in three within-subjects experiments with untrained participants. Study 1 tested whether participants could identify the presentation mode (AC or BC) and channel (left or right) of tones and noises after subjective reference-tone loudness balancing. Study 2 tested whether simultaneous AC+BC presentation increased the number of signals or spatial locations participants could enumerate and discriminate. Study 3 tested whether AC and BC alerts supported identification and response performance during visual-motor multitasking. Study 1 showed that attribution depended jointly on mode and signal type: BC produced higher accuracy at 250 Hz, whereas AC produced higher accuracy for most mid- to high-frequency tones and white noise. Study 2 showed selected BC advantages for tone-count and spatial-count judgments, but simultaneous AC+BC presentation did not produce a statistically reliable increase in enumeration capacity or spatial discrimination. Study 3 showed higher overall alert-identification accuracy for AC, with mode-specific differences concentrated in broadband alerts. Whether a hybrid AC/BC auditory display is beneficial depends on how information is encoded, what participants must discriminate, and the demands of the concurrent task. Overall, hybrid AC/BC displays should be applied selectively. The presentation mode, signal characteristics, and task requirements must be matched rather than assuming that BC or simultaneous AC+BC presentation will improve performance. These results provide design guidance for operational, assistive, and multitask auditory displays."],"dc:description.abstractgeneral":["People often rely on sound when they cannot direct their eyes toward an information source, for example while driving, operating equipment, or working in a busy environment. Most sound-based displays send audio through the air to the ears. Bone conduction uses a transducer to deliver vibration through the skull and surrounding tissues, providing another route to the inner ear while leaving the ear canal open. The open ear can maintain access to environmental sound, although device-mediated bone-conducted audio can still interfere with perception of the surrounding environment. This dissertation examined how people perceive and respond to information sent through air and bone conduction, both separately and simultaneously. Across three studies, air-conducted signals were generally identified more accurately. Bone-conducted presentation produced higher accuracy only for specific low-frequency identification and enumeration tasks. Presenting information through both pathways at the same time did not reliably increase the amount of auditory information people could use. The findings show that these systems work best when the presentation pathway and signal characteristics are matched to the task. The results provide practical guidance for sound-based displays used in work, assistive, and multitasking environments."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:47593"],"dc:identifier.uri":["https://hdl.handle.net/10919/143801"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Signal Detection Theory","Auditory Localization","Divided Attention","Hybrid Auditory Display","Human Factors"],"dc:title":["Human Auditory Perception and Performance Across Air- and Bone-Conduction Listening Pathways"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Industrial and Systems Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:17:29Z"}