{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143818"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143818","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Modulation and Control for High-Frequency GaN-Based Bidirectional AC--DC Converters","abstract":"Alternating-current--direct-current (AC--DC) converters serve as a critical interface between the electric grid and direct-current (DC) loads. With the increasing demand for data center power consumption, renewable energy systems, energy storage systems, electric vehicles (EVs), AC--DC converters are required to reach high efficiency, high power density, high reliability and also support both rectifier-mode and inverter-mode operations. Gallium nitride (GaN) high-electron-mobility transistor (HEMT) devices provide superior switching performance compared with conventional silicon (Si) metal--oxide--semiconductor field-effect transistors (MOSFETs), enabling high-frequency and high-power-density converter designs. Critical-conduction-mode (CRM) operation can further utilize the advantages of GaN devices by achieving zero-voltage switching (ZVS). However, as the switching frequency increases, new challenges arise in zero-current-detection (ZCD) sensing, digital modulation, closed-loop control and increased circulating current. Furthermore, the current distortion issue under non-unity power factor (PF) operation is another challenge for inverter mode operation. This dissertation investigates the sensing, modulation, and control of high-frequency GaN-based bidirectional totem-pole (TP) AC--DC converters. First, a reliable ZCD-sensing-based CRM modulation method is developed for GaN-based TP AC--DC converters. The noise propagation path in the ZCD sensing circuit is analyzed, and a noise-oriented circuit design method is proposed, including component selection guidelines and printed-circuit-board (PCB) layout rules. To avoid false triggering and clamp the maximum switching frequency, a window-based ZCD signal processing method is introduced. In addition, the closed-loop control challenge of high-frequency CRM TP-power factor correction (PFC) converters is addressed. Conventional constant-on-time (COT) control can suffer from input-current total harmonic distortion (THD) due to the resonance between the inductor and switch output capacitances, while variable-on-time (VOT) operation with voltage-mode control (VMC) is sensitive to parameter tolerances. Therefore, an average-current-mode control (ACMC) method with adaptive compensator gain is proposed to directly regulate the AC current and improve the dynamic response near the AC voltage zero-crossing region. The proposed ZCD sensing circuit and closed-loop control methods are verified on a 1~kW GaN-based TP-PFC prototype. Experimental results show noise-free ZCD operation with negligible sensing delay, and the measured input-current THD is 1.97% at full load and remains below 5% over the tested operating range. Second, a sensor-less CRM modulation method is proposed to eliminate the dedicated ZCD sensing circuit and reduce the impact of system response delay. Although improved ZCD circuits can achieve reliable operation, practical converter systems may still suffer from severe electromagnetic-interference (EMI) noise, increased bill-of-materials (BOM) cost, and delay-induced performance degradation, especially when the switching frequency is pushed even higher. Quantitative analysis shows that even a response delay at the 50~ns level can significantly increase the inductor-current ripple under ultra-high-frequency operation. To address this issue, a model-based CRM modulation method is developed, where the synchronous-rectifier (SR) conduction time is calculated based on the sensed average inductor current. The proposed model avoids the complex timing calculation of the second-order resonance between the inductor and switch output capacitances while maintaining good accuracy. The tolerance analysis shows that the model has low sensitivity to the output-capacitance tolerance. With printed-circuit-board (PCB) winding inductors, the proposed method has strong potential for mass-production applications. Experimental comparison with ZCD-based modulation shows reduced inductor current and smaller circulating current. The model-based method is further applied to a 2.2~kW two-channel interleaved TP-PFC prototype with PCB inductors, achieving a measured peak efficiency of 99.02%. Finally, high-frequency CRM operation is extended to inverter-mode applications. Under non-unity-PF operation, the zero-crossing instants of the AC current and AC voltage no longer coincide, which causes an extremely high switching frequency near the AC current zero crossing. To solve this issue, discontinuous-conduction-mode (DCM) modulation with stepwise resonant-dead-time adjustment is proposed to clamp the switching frequency. A ZCD window is also applied to avoid undesired triggering caused by DCM current ringing. In addition, the AC-voltage zero-crossing blanking time used in conventional unipolar modulation can cause current distortion in inverter-mode operation. Although bipolar modulation can avoid this issue, it increases the switching frequency and reduces the benefit of CRM operation. Therefore, a unipolar--bipolar hybrid modulation method is proposed. In this method, blanking time is applied around the AC current zero crossing instead of the AC voltage zero crossing, and bipolar modulation is only used near the voltage zero-crossing region. A compare-value adjustment method is further proposed to achieve seamless transitions between modulation modes without using conventional action-qualifier software forcing. Hardware experiments verify the effectiveness of the proposed DCM frequency-clamping method and hybrid modulation strategy. Overall, this dissertation provides a systematic study of sensing, modulation, and control techniques for high-frequency GaN-based bidirectional TP converters. The proposed methods improve the reliability of CRM operation, reduce current distortion, mitigate delay and tolerance issues, and extend CRM operation from rectifier-mode PFC applications to bidirectional applications.","abstract_html":"Alternating-current--direct-current (AC--DC) converters serve as a critical interface between the electric grid and direct-current (DC) loads. With the increasing demand for data center power consumption, renewable energy systems, energy storage systems, electric vehicles (EVs), AC--DC converters are required to reach high efficiency, high power density, high reliability and also support both rectifier-mode and inverter-mode operations. Gallium nitride (GaN) high-electron-mobility transistor (HEMT) devices provide superior switching performance compared with conventional silicon (Si) metal--oxide--semiconductor field-effect transistors (MOSFETs), enabling high-frequency and high-power-density converter designs. Critical-conduction-mode (CRM) operation can further utilize the advantages of GaN devices by achieving zero-voltage switching (ZVS). However, as the switching frequency increases, new challenges arise in zero-current-detection (ZCD) sensing, digital modulation, closed-loop control and increased circulating current. Furthermore, the current distortion issue under non-unity power factor (PF) operation is another challenge for inverter mode operation. This dissertation investigates the sensing, modulation, and control of high-frequency GaN-based bidirectional totem-pole (TP) AC--DC converters. First, a reliable ZCD-sensing-based CRM modulation method is developed for GaN-based TP AC--DC converters. The noise propagation path in the ZCD sensing circuit is analyzed, and a noise-oriented circuit design method is proposed, including component selection guidelines and printed-circuit-board (PCB) layout rules. To avoid false triggering and clamp the maximum switching frequency, a window-based ZCD signal processing method is introduced. In addition, the closed-loop control challenge of high-frequency CRM TP-power factor correction (PFC) converters is addressed. Conventional constant-on-time (COT) control can suffer from input-current total harmonic distortion (THD) due to the resonance between the inductor and switch output capacitances, while variable-on-time (VOT) operation with voltage-mode control (VMC) is sensitive to parameter tolerances. Therefore, an average-current-mode control (ACMC) method with adaptive compensator gain is proposed to directly regulate the AC current and improve the dynamic response near the AC voltage zero-crossing region. The proposed ZCD sensing circuit and closed-loop control methods are verified on a 1~kW GaN-based TP-PFC prototype. Experimental results show noise-free ZCD operation with negligible sensing delay, and the measured input-current THD is 1.97% at full load and remains below 5% over the tested operating range. Second, a sensor-less CRM modulation method is proposed to eliminate the dedicated ZCD sensing circuit and reduce the impact of system response delay. Although improved ZCD circuits can achieve reliable operation, practical converter systems may still suffer from severe electromagnetic-interference (EMI) noise, increased bill-of-materials (BOM) cost, and delay-induced performance degradation, especially when the switching frequency is pushed even higher. Quantitative analysis shows that even a response delay at the 50~ns level can significantly increase the inductor-current ripple under ultra-high-frequency operation. To address this issue, a model-based CRM modulation method is developed, where the synchronous-rectifier (SR) conduction time is calculated based on the sensed average inductor current. The proposed model avoids the complex timing calculation of the second-order resonance between the inductor and switch output capacitances while maintaining good accuracy. The tolerance analysis shows that the model has low sensitivity to the output-capacitance tolerance. With printed-circuit-board (PCB) winding inductors, the proposed method has strong potential for mass-production applications. Experimental comparison with ZCD-based modulation shows reduced inductor current and smaller circulating current. The model-based method is further applied to a 2.2~kW two-channel interleaved TP-PFC prototype with PCB inductors, achieving a measured peak efficiency of 99.02%. Finally, high-frequency CRM operation is extended to inverter-mode applications. Under non-unity-PF operation, the zero-crossing instants of the AC current and AC voltage no longer coincide, which causes an extremely high switching frequency near the AC current zero crossing. To solve this issue, discontinuous-conduction-mode (DCM) modulation with stepwise resonant-dead-time adjustment is proposed to clamp the switching frequency. A ZCD window is also applied to avoid undesired triggering caused by DCM current ringing. In addition, the AC-voltage zero-crossing blanking time used in conventional unipolar modulation can cause current distortion in inverter-mode operation. Although bipolar modulation can avoid this issue, it increases the switching frequency and reduces the benefit of CRM operation. Therefore, a unipolar--bipolar hybrid modulation method is proposed. In this method, blanking time is applied around the AC current zero crossing instead of the AC voltage zero crossing, and bipolar modulation is only used near the voltage zero-crossing region. A compare-value adjustment method is further proposed to achieve seamless transitions between modulation modes without using conventional action-qualifier software forcing. Hardware experiments verify the effectiveness of the proposed DCM frequency-clamping method and hybrid modulation strategy. Overall, this dissertation provides a systematic study of sensing, modulation, and control techniques for high-frequency GaN-based bidirectional TP converters. The proposed methods improve the reliability of CRM operation, reduce current distortion, mitigate delay and tolerance issues, and extend CRM operation from rectifier-mode PFC applications to bidirectional applications.","abstract_has_math":false,"creators":["Chen, Xingyu"],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Li, Qiang"],"committee_members":["Centeno, Virgilio A.","Southward, Steve C.","Zhang, Yuhao","Dimarino, Christina Marie"],"year":2026,"date_issued":"2026-09-15","date_published":"2026-09-15","updated_at":"2026-11-18T20:13:53Z","subjects":["bidirectional","critical conduction mode (CRM)","inverter","reactive power","rectifier"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47509"],"render_values":[{"text":"vt_gsexam:47509","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143818","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143818","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143818","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Li, Qiang"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Centeno, Virgilio A.","Southward, Steve C.","Zhang, Yuhao","Dimarino, Christina Marie"]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Chen, Xingyu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-09-16T08:00:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-09-16T08:00:38Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-09-15"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bidirectional","critical conduction mode (CRM)","inverter","reactive power","rectifier"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47509"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143818"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Alternating-current--direct-current (AC--DC) converters serve as a critical interface between the electric grid and direct-current (DC) loads. With the increasing demand for data center power consumption, renewable energy systems, energy storage systems, electric vehicles (EVs), AC--DC converters are required to reach high efficiency, high power density, high reliability and also support both rectifier-mode and inverter-mode operations. Gallium nitride (GaN) high-electron-mobility transistor (HEMT) devices provide superior switching performance compared with conventional silicon (Si) metal--oxide--semiconductor field-effect transistors (MOSFETs), enabling high-frequency and high-power-density converter designs. Critical-conduction-mode (CRM) operation can further utilize the advantages of GaN devices by achieving zero-voltage switching (ZVS). However, as the switching frequency increases, new challenges arise in zero-current-detection (ZCD) sensing, digital modulation, closed-loop control and increased circulating current. Furthermore, the current distortion issue under non-unity power factor (PF) operation is another challenge for inverter mode operation. This dissertation investigates the sensing, modulation, and control of high-frequency GaN-based bidirectional totem-pole (TP) AC--DC converters. First, a reliable ZCD-sensing-based CRM modulation method is developed for GaN-based TP AC--DC converters. The noise propagation path in the ZCD sensing circuit is analyzed, and a noise-oriented circuit design method is proposed, including component selection guidelines and printed-circuit-board (PCB) layout rules. To avoid false triggering and clamp the maximum switching frequency, a window-based ZCD signal processing method is introduced. In addition, the closed-loop control challenge of high-frequency CRM TP-power factor correction (PFC) converters is addressed. Conventional constant-on-time (COT) control can suffer from input-current total harmonic distortion (THD) due to the resonance between the inductor and switch output capacitances, while variable-on-time (VOT) operation with voltage-mode control (VMC) is sensitive to parameter tolerances. Therefore, an average-current-mode control (ACMC) method with adaptive compensator gain is proposed to directly regulate the AC current and improve the dynamic response near the AC voltage zero-crossing region. The proposed ZCD sensing circuit and closed-loop control methods are verified on a 1~kW GaN-based TP-PFC prototype. Experimental results show noise-free ZCD operation with negligible sensing delay, and the measured input-current THD is 1.97% at full load and remains below 5% over the tested operating range. Second, a sensor-less CRM modulation method is proposed to eliminate the dedicated ZCD sensing circuit and reduce the impact of system response delay. Although improved ZCD circuits can achieve reliable operation, practical converter systems may still suffer from severe electromagnetic-interference (EMI) noise, increased bill-of-materials (BOM) cost, and delay-induced performance degradation, especially when the switching frequency is pushed even higher. Quantitative analysis shows that even a response delay at the 50~ns level can significantly increase the inductor-current ripple under ultra-high-frequency operation. To address this issue, a model-based CRM modulation method is developed, where the synchronous-rectifier (SR) conduction time is calculated based on the sensed average inductor current. The proposed model avoids the complex timing calculation of the second-order resonance between the inductor and switch output capacitances while maintaining good accuracy. The tolerance analysis shows that the model has low sensitivity to the output-capacitance tolerance. With printed-circuit-board (PCB) winding inductors, the proposed method has strong potential for mass-production applications. Experimental comparison with ZCD-based modulation shows reduced inductor current and smaller circulating current. The model-based method is further applied to a 2.2~kW two-channel interleaved TP-PFC prototype with PCB inductors, achieving a measured peak efficiency of 99.02%. Finally, high-frequency CRM operation is extended to inverter-mode applications. Under non-unity-PF operation, the zero-crossing instants of the AC current and AC voltage no longer coincide, which causes an extremely high switching frequency near the AC current zero crossing. To solve this issue, discontinuous-conduction-mode (DCM) modulation with stepwise resonant-dead-time adjustment is proposed to clamp the switching frequency. A ZCD window is also applied to avoid undesired triggering caused by DCM current ringing. In addition, the AC-voltage zero-crossing blanking time used in conventional unipolar modulation can cause current distortion in inverter-mode operation. Although bipolar modulation can avoid this issue, it increases the switching frequency and reduces the benefit of CRM operation. Therefore, a unipolar--bipolar hybrid modulation method is proposed. In this method, blanking time is applied around the AC current zero crossing instead of the AC voltage zero crossing, and bipolar modulation is only used near the voltage zero-crossing region. A compare-value adjustment method is further proposed to achieve seamless transitions between modulation modes without using conventional action-qualifier software forcing. Hardware experiments verify the effectiveness of the proposed DCM frequency-clamping method and hybrid modulation strategy. Overall, this dissertation provides a systematic study of sensing, modulation, and control techniques for high-frequency GaN-based bidirectional TP converters. The proposed methods improve the reliability of CRM operation, reduce current distortion, mitigate delay and tolerance issues, and extend CRM operation from rectifier-mode PFC applications to bidirectional applications."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Power factor correction (PFC) rectifiers are widely used to connect the electric grid with electronic devices including data centers, battery systems, electric vehicles (EVs), and renewable energy systems. Many of these systems need to transfer power not only from the grid to a direct-current load, but also in the reverse direction. For example, an EV charger may need to charge the vehicle battery from the grid and may also need to send energy back to the grid or support local loads. Therefore, efficient and compact bidirectional power converters are becoming increasingly important. Gallium nitride (GaN) power devices are promising for these applications because they can switch much faster than traditional silicon (Si) devices. Faster switching can reduce the size of magnetic components and improve the power density of the converter. However, high-frequency operation also makes the converter more difficult to control. The timing of the switching actions becomes very sensitive, the circuit is more easily affected by noise, and small sensing or control delays can noticeably degrade the converter performance. This dissertation studies these challenges in a bidirectional totem-pole power-factor-correction (TP-PFC) converter, which is a highly efficient circuit topology for grid-connected power conversion. The first part of this dissertation focuses on reliable zero-current-detection (ZCD) sensing. In critical-conduction-mode (CRM) operation, the converter needs to detect the moment when the inductor current reaches zero so that the next switching cycle can start at the proper time. If this detection is delayed, missed, or falsely triggered by noise, the converter may generate distorted current or lose regulation. This work analyzes the noise path in the sensing circuit and provides design guidelines for component selection and printed-circuit-board (PCB) layout. A window-based method is also introduced to process the ZCD signal and prevent false triggering. In addition, a closed-loop control method is proposed to directly regulate the alternating-current (AC) input current and reduce total harmonic distortion (THD). Experiments on a 1~kW prototype show reliable ZCD operation and low current distortion. The second part of this dissertation investigates how to remove the dedicated ZCD sensing circuit. Although a well-designed ZCD circuit can work reliably, some practical systems may still prefer reducing the sensing components, lower the bill-of-materials (BOM) cost, or avoid noise-sensitive sensing paths. In very-high-frequency operation, even the small response delay can increase the inductor-current ripple and reduce efficiency. To solve this problem, a sensor-less CRM modulation method is proposed. Instead of directly detecting the zero-current point, the controller calculates the required switching timing based on a simplified circuit model and the measured average inductor current. This method avoids complicated resonance calculations while maintaining good accuracy. It is compared to sensor-based modulation and proves the improvement. It is also verified on a 2.2~kW interleaved prototype, where a peak efficiency of 99.02% is measured. The third part of this dissertation extends high-frequency CRM operation from rectifier mode to inverter mode. This is important for bidirectional applications such as energy storage systems and EV under vehicle-to-grid operation. In inverter mode, the converter may need to provide reactive power, which means that the AC voltage and AC current may not cross zero at the same time. This creates two major challenges. First, the switching frequency can become extremely high near the AC current zero crossing. To address this, a discontinuous-conduction-mode (DCM) method with stepwise dead-time adjustment is proposed to limit the switching frequency. Second, the blanking time commonly used around the AC voltage zero crossing can cause current distortion. To solve this, a hybrid modulation method is proposed, combining the benefits of unipolar and bipolar modulation. The converter uses bipolar modulation only near the voltage zero-crossing region and keeps unipolar modulation in the rest of the line cycle. Hardware experiments verify that the proposed method can limit the switching frequency and reduce current distortion in inverter-mode operation. In summary, this dissertation develops sensing, modulation, and control methods for high-frequency GaN-based bidirectional AC--DC power converters. The proposed techniques improve the reliability of high-frequency switching, reduce current distortion, lower the impact of sensing and control delays, and enable efficient bidirectional operation for future grid-connected energy systems and EV applications."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Modulation and Control for High-Frequency GaN-Based Bidirectional AC--DC Converters"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Li, Qiang"],"dc:contributor.committeemember":["Centeno, Virgilio A.","Southward, Steve C.","Zhang, Yuhao","Dimarino, Christina Marie"],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Chen, Xingyu"],"dc:date.accessioned":["2026-09-16T08:00:38Z"],"dc:date.available":["2026-09-16T08:00:38Z"],"dc:date.issued":["2026-09-15"],"dc:description.abstract":["Alternating-current--direct-current (AC--DC) converters serve as a critical interface between the electric grid and direct-current (DC) loads. With the increasing demand for data center power consumption, renewable energy systems, energy storage systems, electric vehicles (EVs), AC--DC converters are required to reach high efficiency, high power density, high reliability and also support both rectifier-mode and inverter-mode operations. Gallium nitride (GaN) high-electron-mobility transistor (HEMT) devices provide superior switching performance compared with conventional silicon (Si) metal--oxide--semiconductor field-effect transistors (MOSFETs), enabling high-frequency and high-power-density converter designs. Critical-conduction-mode (CRM) operation can further utilize the advantages of GaN devices by achieving zero-voltage switching (ZVS). However, as the switching frequency increases, new challenges arise in zero-current-detection (ZCD) sensing, digital modulation, closed-loop control and increased circulating current. Furthermore, the current distortion issue under non-unity power factor (PF) operation is another challenge for inverter mode operation. This dissertation investigates the sensing, modulation, and control of high-frequency GaN-based bidirectional totem-pole (TP) AC--DC converters. First, a reliable ZCD-sensing-based CRM modulation method is developed for GaN-based TP AC--DC converters. The noise propagation path in the ZCD sensing circuit is analyzed, and a noise-oriented circuit design method is proposed, including component selection guidelines and printed-circuit-board (PCB) layout rules. To avoid false triggering and clamp the maximum switching frequency, a window-based ZCD signal processing method is introduced. In addition, the closed-loop control challenge of high-frequency CRM TP-power factor correction (PFC) converters is addressed. Conventional constant-on-time (COT) control can suffer from input-current total harmonic distortion (THD) due to the resonance between the inductor and switch output capacitances, while variable-on-time (VOT) operation with voltage-mode control (VMC) is sensitive to parameter tolerances. Therefore, an average-current-mode control (ACMC) method with adaptive compensator gain is proposed to directly regulate the AC current and improve the dynamic response near the AC voltage zero-crossing region. The proposed ZCD sensing circuit and closed-loop control methods are verified on a 1~kW GaN-based TP-PFC prototype. Experimental results show noise-free ZCD operation with negligible sensing delay, and the measured input-current THD is 1.97% at full load and remains below 5% over the tested operating range. Second, a sensor-less CRM modulation method is proposed to eliminate the dedicated ZCD sensing circuit and reduce the impact of system response delay. Although improved ZCD circuits can achieve reliable operation, practical converter systems may still suffer from severe electromagnetic-interference (EMI) noise, increased bill-of-materials (BOM) cost, and delay-induced performance degradation, especially when the switching frequency is pushed even higher. Quantitative analysis shows that even a response delay at the 50~ns level can significantly increase the inductor-current ripple under ultra-high-frequency operation. To address this issue, a model-based CRM modulation method is developed, where the synchronous-rectifier (SR) conduction time is calculated based on the sensed average inductor current. The proposed model avoids the complex timing calculation of the second-order resonance between the inductor and switch output capacitances while maintaining good accuracy. The tolerance analysis shows that the model has low sensitivity to the output-capacitance tolerance. With printed-circuit-board (PCB) winding inductors, the proposed method has strong potential for mass-production applications. Experimental comparison with ZCD-based modulation shows reduced inductor current and smaller circulating current. The model-based method is further applied to a 2.2~kW two-channel interleaved TP-PFC prototype with PCB inductors, achieving a measured peak efficiency of 99.02%. Finally, high-frequency CRM operation is extended to inverter-mode applications. Under non-unity-PF operation, the zero-crossing instants of the AC current and AC voltage no longer coincide, which causes an extremely high switching frequency near the AC current zero crossing. To solve this issue, discontinuous-conduction-mode (DCM) modulation with stepwise resonant-dead-time adjustment is proposed to clamp the switching frequency. A ZCD window is also applied to avoid undesired triggering caused by DCM current ringing. In addition, the AC-voltage zero-crossing blanking time used in conventional unipolar modulation can cause current distortion in inverter-mode operation. Although bipolar modulation can avoid this issue, it increases the switching frequency and reduces the benefit of CRM operation. Therefore, a unipolar--bipolar hybrid modulation method is proposed. In this method, blanking time is applied around the AC current zero crossing instead of the AC voltage zero crossing, and bipolar modulation is only used near the voltage zero-crossing region. A compare-value adjustment method is further proposed to achieve seamless transitions between modulation modes without using conventional action-qualifier software forcing. Hardware experiments verify the effectiveness of the proposed DCM frequency-clamping method and hybrid modulation strategy. Overall, this dissertation provides a systematic study of sensing, modulation, and control techniques for high-frequency GaN-based bidirectional TP converters. The proposed methods improve the reliability of CRM operation, reduce current distortion, mitigate delay and tolerance issues, and extend CRM operation from rectifier-mode PFC applications to bidirectional applications."],"dc:description.abstractgeneral":["Power factor correction (PFC) rectifiers are widely used to connect the electric grid with electronic devices including data centers, battery systems, electric vehicles (EVs), and renewable energy systems. Many of these systems need to transfer power not only from the grid to a direct-current load, but also in the reverse direction. For example, an EV charger may need to charge the vehicle battery from the grid and may also need to send energy back to the grid or support local loads. Therefore, efficient and compact bidirectional power converters are becoming increasingly important. Gallium nitride (GaN) power devices are promising for these applications because they can switch much faster than traditional silicon (Si) devices. Faster switching can reduce the size of magnetic components and improve the power density of the converter. However, high-frequency operation also makes the converter more difficult to control. The timing of the switching actions becomes very sensitive, the circuit is more easily affected by noise, and small sensing or control delays can noticeably degrade the converter performance. This dissertation studies these challenges in a bidirectional totem-pole power-factor-correction (TP-PFC) converter, which is a highly efficient circuit topology for grid-connected power conversion. The first part of this dissertation focuses on reliable zero-current-detection (ZCD) sensing. In critical-conduction-mode (CRM) operation, the converter needs to detect the moment when the inductor current reaches zero so that the next switching cycle can start at the proper time. If this detection is delayed, missed, or falsely triggered by noise, the converter may generate distorted current or lose regulation. This work analyzes the noise path in the sensing circuit and provides design guidelines for component selection and printed-circuit-board (PCB) layout. A window-based method is also introduced to process the ZCD signal and prevent false triggering. In addition, a closed-loop control method is proposed to directly regulate the alternating-current (AC) input current and reduce total harmonic distortion (THD). Experiments on a 1~kW prototype show reliable ZCD operation and low current distortion. The second part of this dissertation investigates how to remove the dedicated ZCD sensing circuit. Although a well-designed ZCD circuit can work reliably, some practical systems may still prefer reducing the sensing components, lower the bill-of-materials (BOM) cost, or avoid noise-sensitive sensing paths. In very-high-frequency operation, even the small response delay can increase the inductor-current ripple and reduce efficiency. To solve this problem, a sensor-less CRM modulation method is proposed. Instead of directly detecting the zero-current point, the controller calculates the required switching timing based on a simplified circuit model and the measured average inductor current. This method avoids complicated resonance calculations while maintaining good accuracy. It is compared to sensor-based modulation and proves the improvement. It is also verified on a 2.2~kW interleaved prototype, where a peak efficiency of 99.02% is measured. The third part of this dissertation extends high-frequency CRM operation from rectifier mode to inverter mode. This is important for bidirectional applications such as energy storage systems and EV under vehicle-to-grid operation. In inverter mode, the converter may need to provide reactive power, which means that the AC voltage and AC current may not cross zero at the same time. This creates two major challenges. First, the switching frequency can become extremely high near the AC current zero crossing. To address this, a discontinuous-conduction-mode (DCM) method with stepwise dead-time adjustment is proposed to limit the switching frequency. Second, the blanking time commonly used around the AC voltage zero crossing can cause current distortion. To solve this, a hybrid modulation method is proposed, combining the benefits of unipolar and bipolar modulation. The converter uses bipolar modulation only near the voltage zero-crossing region and keeps unipolar modulation in the rest of the line cycle. Hardware experiments verify that the proposed method can limit the switching frequency and reduce current distortion in inverter-mode operation. In summary, this dissertation develops sensing, modulation, and control methods for high-frequency GaN-based bidirectional AC--DC power converters. The proposed techniques improve the reliability of high-frequency switching, reduce current distortion, lower the impact of sensing and control delays, and enable efficient bidirectional operation for future grid-connected energy systems and EV applications."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:47509"],"dc:identifier.uri":["https://hdl.handle.net/10919/143818"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["bidirectional","critical conduction mode (CRM)","inverter","reactive power","rectifier"],"dc:title":["Modulation and Control for High-Frequency GaN-Based Bidirectional AC--DC Converters"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:13:53Z"}