{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/143907"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/143907","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Effects of Back-Support Exoskeletons on Balance Recovery From Overground Slips and Trips","abstract":"Back-support exoskeletons (BSEs) are widely used in industry to reduce risk factors for work-related musculoskeletal disorders during manual material handling tasks. They may, however, increase fall risk by adversely affecting balance recovery after slips and trips. Prior work on BSEs and their effects on balance recovery has mainly relied on treadmill or lean-release perturbations to simulate slips and trips, which may elicit different recovery responses than overground slips and trips. This dissertation comprises three studies that investigated the effects of passive BSEs on fall rate and balance recovery after overground slips and trips. The purpose of the first study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground trips. Two commercial passive BSEs with distinct designs were selected: the HeroWear, which has soft elements and elastic bands, and the BackX, which has a rigid frame and mechanical torque generators. Participants were exposed to two overground trips, one with and one without a BSE. The results did not show a difference in fall rate after trips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including shorter recovery step time and shorter recovery step length with HeroWear and, when participants used an elevating recovery strategy, greater hip drop with BackX. The purpose of the second study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground slips. Participants were exposed to a single overground slip with or without a BSE. The results did not show a difference in fall rate after slips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including smaller peak hip drop with HeroWear and greater slip distance with BackX. The purpose of the third study was to investigate the effects of anterior load carriage and BackX on fall rate and balance recovery after lab-induced overground trips. The results did not show an increase in fall rate after trips with anterior load carriage. However, anterior load carriage elicited changes in balance recovery kinematics, including longer recovery step time, longer recovery step length, greater hip drop in females, and smaller torso flexion angle. Additionally, the results did not show an increase in fall rate after trips with BackX during anterior load carriage. However, BackX elicited changes in balance recovery kinematics, including a shorter recovery step time and smaller hip drop. Taken together, these studies provide insight into how passive BSEs affect balance recovery after overground slips and trips. The findings do not support the concern that these BSEs increase fall rate after slips or trips. However, BSE effects on balance recovery kinematics were device-specific and varied from beneficial to adverse, which can inform BSE use in workplaces where slips and trips are common.","abstract_html":"Back-support exoskeletons (BSEs) are widely used in industry to reduce risk factors for work-related musculoskeletal disorders during manual material handling tasks. They may, however, increase fall risk by adversely affecting balance recovery after slips and trips. Prior work on BSEs and their effects on balance recovery has mainly relied on treadmill or lean-release perturbations to simulate slips and trips, which may elicit different recovery responses than overground slips and trips. This dissertation comprises three studies that investigated the effects of passive BSEs on fall rate and balance recovery after overground slips and trips. The purpose of the first study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground trips. Two commercial passive BSEs with distinct designs were selected: the HeroWear, which has soft elements and elastic bands, and the BackX, which has a rigid frame and mechanical torque generators. Participants were exposed to two overground trips, one with and one without a BSE. The results did not show a difference in fall rate after trips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including shorter recovery step time and shorter recovery step length with HeroWear and, when participants used an elevating recovery strategy, greater hip drop with BackX. The purpose of the second study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground slips. Participants were exposed to a single overground slip with or without a BSE. The results did not show a difference in fall rate after slips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including smaller peak hip drop with HeroWear and greater slip distance with BackX. The purpose of the third study was to investigate the effects of anterior load carriage and BackX on fall rate and balance recovery after lab-induced overground trips. The results did not show an increase in fall rate after trips with anterior load carriage. However, anterior load carriage elicited changes in balance recovery kinematics, including longer recovery step time, longer recovery step length, greater hip drop in females, and smaller torso flexion angle. Additionally, the results did not show an increase in fall rate after trips with BackX during anterior load carriage. However, BackX elicited changes in balance recovery kinematics, including a shorter recovery step time and smaller hip drop. Taken together, these studies provide insight into how passive BSEs affect balance recovery after overground slips and trips. The findings do not support the concern that these BSEs increase fall rate after slips or trips. However, BSE effects on balance recovery kinematics were device-specific and varied from beneficial to adverse, which can inform BSE use in workplaces where slips and trips are common.","abstract_has_math":false,"creators":["Freidouny, Mohammadreza"],"institution":"Virginia Tech","degree_name":"Doctor of Philosophy","degree_level":"doctoral","degree_discipline":"Industrial and Systems Engineering","degree_department":"Industrial and Systems Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Madigan, Michael L."],"committee_members":["Kim, Sun Wook","Nussbaum, Maury A.","Lim, Sol Ie"],"year":2026,"date_issued":"2026-10-13","date_published":"2026-10-13","updated_at":"2026-11-18T20:22:34Z","subjects":["exoskeletons","slips","trips","falls","balance recovery","anterior load carriage","manual material handling"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47828"],"render_values":[{"text":"vt_gsexam:47828","href":null,"code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10919/143907","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10919/143907","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F143907","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Madigan, Michael L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Kim, Sun Wook","Nussbaum, Maury A.","Lim, Sol Ie"]},{"key":"dc:contributor.department","label":"Department","values":["Industrial and Systems Engineering"]},{"key":"dc:creator","label":"Author","values":["Freidouny, Mohammadreza"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-10-14T08:00:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-10-14T08:00:11Z"]},{"key":"dc:date.issued","label":"Date","values":["2026-10-13"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["exoskeletons","slips","trips","falls","balance recovery","anterior load carriage","manual material handling"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["vt_gsexam:47828"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10919/143907"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Back-support exoskeletons (BSEs) are widely used in industry to reduce risk factors for work-related musculoskeletal disorders during manual material handling tasks. They may, however, increase fall risk by adversely affecting balance recovery after slips and trips. Prior work on BSEs and their effects on balance recovery has mainly relied on treadmill or lean-release perturbations to simulate slips and trips, which may elicit different recovery responses than overground slips and trips. This dissertation comprises three studies that investigated the effects of passive BSEs on fall rate and balance recovery after overground slips and trips. The purpose of the first study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground trips. Two commercial passive BSEs with distinct designs were selected: the HeroWear, which has soft elements and elastic bands, and the BackX, which has a rigid frame and mechanical torque generators. Participants were exposed to two overground trips, one with and one without a BSE. The results did not show a difference in fall rate after trips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including shorter recovery step time and shorter recovery step length with HeroWear and, when participants used an elevating recovery strategy, greater hip drop with BackX. The purpose of the second study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground slips. Participants were exposed to a single overground slip with or without a BSE. The results did not show a difference in fall rate after slips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including smaller peak hip drop with HeroWear and greater slip distance with BackX. The purpose of the third study was to investigate the effects of anterior load carriage and BackX on fall rate and balance recovery after lab-induced overground trips. The results did not show an increase in fall rate after trips with anterior load carriage. However, anterior load carriage elicited changes in balance recovery kinematics, including longer recovery step time, longer recovery step length, greater hip drop in females, and smaller torso flexion angle. Additionally, the results did not show an increase in fall rate after trips with BackX during anterior load carriage. However, BackX elicited changes in balance recovery kinematics, including a shorter recovery step time and smaller hip drop. Taken together, these studies provide insight into how passive BSEs affect balance recovery after overground slips and trips. The findings do not support the concern that these BSEs increase fall rate after slips or trips. However, BSE effects on balance recovery kinematics were device-specific and varied from beneficial to adverse, which can inform BSE use in workplaces where slips and trips are common."]},{"key":"dc:description.abstractgeneral","label":"General Abstract","values":["Back-support exoskeletons are wearable devices used by workers in many industries to reduce lower-back injuries from tasks such as lifting. However, there is a concern that these devices could increase the risk of falling from a slip or trip. The goal of this dissertation was to examine how passive back-support exoskeletons (i.e., those that do not require an external power source) affect a person's ability to recover from slips and trips. To achieve this goal, over 50 participants were recruited and exposed to slips and trips in a laboratory while wearing or not wearing a back-support exoskeleton. The first study examined how back-support exoskeletons affect recovery from trips. Back-support exoskeletons did not increase the rate of falls after trips but made some changes in balance recovery. The second study examined how back-support exoskeletons affect recovery from slips. Back-support exoskeletons did not increase the rate of falls after slips but made some changes in balance recovery. The third study examined how carrying a load in front of the body affects recovery from trips, with and without a back-support exoskeleton. Carrying a load on its own did not increase the rate of falls after trips but made some changes in balance recovery. Wearing a back-support exoskeleton with a front load did not increase the rate of falls after trips but made some changes in balance recovery. These findings suggest that passive back-support exoskeletons do not make falls from slips and trips more likely, but their effects on balance recovery are device-specific and may either improve or impair particular aspects of recovery, depending on the user and the balance recovery strategy they adopt."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Doctor of Philosophy"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["ETD"]},{"key":"dc:title","label":"Title","values":["Effects of Back-Support Exoskeletons on Balance Recovery From Overground Slips and Trips"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Madigan, Michael L."],"dc:contributor.committeemember":["Kim, Sun Wook","Nussbaum, Maury A.","Lim, Sol Ie"],"dc:contributor.department":["Industrial and Systems Engineering"],"dc:creator":["Freidouny, Mohammadreza"],"dc:date.accessioned":["2026-10-14T08:00:11Z"],"dc:date.available":["2026-10-14T08:00:11Z"],"dc:date.issued":["2026-10-13"],"dc:description.abstract":["Back-support exoskeletons (BSEs) are widely used in industry to reduce risk factors for work-related musculoskeletal disorders during manual material handling tasks. They may, however, increase fall risk by adversely affecting balance recovery after slips and trips. Prior work on BSEs and their effects on balance recovery has mainly relied on treadmill or lean-release perturbations to simulate slips and trips, which may elicit different recovery responses than overground slips and trips. This dissertation comprises three studies that investigated the effects of passive BSEs on fall rate and balance recovery after overground slips and trips. The purpose of the first study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground trips. Two commercial passive BSEs with distinct designs were selected: the HeroWear, which has soft elements and elastic bands, and the BackX, which has a rigid frame and mechanical torque generators. Participants were exposed to two overground trips, one with and one without a BSE. The results did not show a difference in fall rate after trips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including shorter recovery step time and shorter recovery step length with HeroWear and, when participants used an elevating recovery strategy, greater hip drop with BackX. The purpose of the second study was to investigate the effects of BSEs on fall rate and balance recovery after lab-induced overground slips. Participants were exposed to a single overground slip with or without a BSE. The results did not show a difference in fall rate after slips between wearing and not wearing a BSE, or between BackX and HeroWear. However, BSEs elicited changes in balance recovery kinematics, including smaller peak hip drop with HeroWear and greater slip distance with BackX. The purpose of the third study was to investigate the effects of anterior load carriage and BackX on fall rate and balance recovery after lab-induced overground trips. The results did not show an increase in fall rate after trips with anterior load carriage. However, anterior load carriage elicited changes in balance recovery kinematics, including longer recovery step time, longer recovery step length, greater hip drop in females, and smaller torso flexion angle. Additionally, the results did not show an increase in fall rate after trips with BackX during anterior load carriage. However, BackX elicited changes in balance recovery kinematics, including a shorter recovery step time and smaller hip drop. Taken together, these studies provide insight into how passive BSEs affect balance recovery after overground slips and trips. The findings do not support the concern that these BSEs increase fall rate after slips or trips. However, BSE effects on balance recovery kinematics were device-specific and varied from beneficial to adverse, which can inform BSE use in workplaces where slips and trips are common."],"dc:description.abstractgeneral":["Back-support exoskeletons are wearable devices used by workers in many industries to reduce lower-back injuries from tasks such as lifting. However, there is a concern that these devices could increase the risk of falling from a slip or trip. The goal of this dissertation was to examine how passive back-support exoskeletons (i.e., those that do not require an external power source) affect a person's ability to recover from slips and trips. To achieve this goal, over 50 participants were recruited and exposed to slips and trips in a laboratory while wearing or not wearing a back-support exoskeleton. The first study examined how back-support exoskeletons affect recovery from trips. Back-support exoskeletons did not increase the rate of falls after trips but made some changes in balance recovery. The second study examined how back-support exoskeletons affect recovery from slips. Back-support exoskeletons did not increase the rate of falls after slips but made some changes in balance recovery. The third study examined how carrying a load in front of the body affects recovery from trips, with and without a back-support exoskeleton. Carrying a load on its own did not increase the rate of falls after trips but made some changes in balance recovery. Wearing a back-support exoskeleton with a front load did not increase the rate of falls after trips but made some changes in balance recovery. These findings suggest that passive back-support exoskeletons do not make falls from slips and trips more likely, but their effects on balance recovery are device-specific and may either improve or impair particular aspects of recovery, depending on the user and the balance recovery strategy they adopt."],"dc:description.degree":["Doctor of Philosophy"],"dc:format.medium":["ETD"],"dc:identifier.other":["vt_gsexam:47828"],"dc:identifier.uri":["https://hdl.handle.net/10919/143907"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["exoskeletons","slips","trips","falls","balance recovery","anterior load carriage","manual material handling"],"dc:title":["Effects of Back-Support Exoskeletons on Balance Recovery From Overground Slips and Trips"],"dc:type":["Dissertation"],"thesis:degree_discipline":["Industrial and Systems Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Doctor of Philosophy"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:22:34Z"}