{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/31456"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/31456","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Investigation of operating conditions in stirred ball milling of coal","abstract":"As a prerequisite to producing super-clean coal with any physical coal cleaning process, such as microbubble flotation, the feed coal must be micronized to liberate the finely disseminated mineral matter. The stirred ball mill is regarded as one of the most efficient devices for micronizing coal. Using a five-inch batch mill, the optimum operating conditions have been determined in terms of media size, feed size, media type, stirring speed and percent solids. The rates of breakage determined with monosized feeds are compared on the basis of specific energy consumption. It has been found that a 20:1 ball size/particle size ratio gives optimum grinding conditions. With the fine particle sizes obtained using stirred ball milling, as well as other fine grinding techniques, a growing concern has been generated regarding the accuracy of these size distributions. An automated technique has been developed in which a complete mass balanced size distribution can be obtained using an Elzone® 80XY particle size analyzer. A computer program is used to blend the data from successively smaller Orifice tubes, as well as, to determine the weight percent of material in a particle size distribution finer than the lower detection limit of the analyzer. This result is then used to correct the distribution for the missing fine material.","abstract_html":"As a prerequisite to producing super-clean coal with any physical coal cleaning process, such as microbubble flotation, the feed coal must be micronized to liberate the finely disseminated mineral matter. The stirred ball mill is regarded as one of the most efficient devices for micronizing coal. Using a five-inch batch mill, the optimum operating conditions have been determined in terms of media size, feed size, media type, stirring speed and percent solids. The rates of breakage determined with monosized feeds are compared on the basis of specific energy consumption. It has been found that a 20:1 ball size/particle size ratio gives optimum grinding conditions. With the fine particle sizes obtained using stirred ball milling, as well as other fine grinding techniques, a growing concern has been generated regarding the accuracy of these size distributions. An automated technique has been developed in which a complete mass balanced size distribution can be obtained using an Elzone® 80XY particle size analyzer. A computer program is used to blend the data from successively smaller Orifice tubes, as well as, to determine the weight percent of material in a particle size distribution finer than the lower detection limit of the analyzer. This result is then used to correct the distribution for the missing fine material.","abstract_has_math":false,"creators":["Mankosa, Michael James"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mining and Minerals Engineering","degree_department":"Mining and Minerals Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1986,"date_issued":"1986","date_published":"1986","updated_at":"2026-11-18T20:16:46Z","subjects":["Coal balls","Grinding machines"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03122009-040831"],"render_values":[{"text":"etd-03122009-040831","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03122009-040831/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-03122009-040831/","href":"http://scholar.lib.vt.edu/theses/available/etd-03122009-040831/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/31456","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/31456","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F31456","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mining and Minerals Engineering"]},{"key":"dc:creator","label":"Author","values":["Mankosa, Michael James"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-03-12"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T20:32:35Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T20:32:35Z","2009-03-12"]},{"key":"dc:date.issued","label":"Date","values":["1986"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-03-12"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1986.M3664.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 15285823"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mining and Minerals Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1986.M3664"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Coal balls","Grinding machines"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03122009-040831"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03122009-040831/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/31456"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["As a prerequisite to producing super-clean coal with any physical coal cleaning process, such as microbubble flotation, the feed coal must be micronized to liberate the finely disseminated mineral matter. The stirred ball mill is regarded as one of the most efficient devices for micronizing coal. Using a five-inch batch mill, the optimum operating conditions have been determined in terms of media size, feed size, media type, stirring speed and percent solids. The rates of breakage determined with monosized feeds are compared on the basis of specific energy consumption. It has been found that a 20:1 ball size/particle size ratio gives optimum grinding conditions. With the fine particle sizes obtained using stirred ball milling, as well as other fine grinding techniques, a growing concern has been generated regarding the accuracy of these size distributions. An automated technique has been developed in which a complete mass balanced size distribution can be obtained using an Elzone® 80XY particle size analyzer. A computer program is used to blend the data from successively smaller Orifice tubes, as well as, to determine the weight percent of material in a particle size distribution finer than the lower detection limit of the analyzer. This result is then used to correct the distribution for the missing fine material."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 123 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Investigation of operating conditions in stirred ball milling of coal"]}]}],"canonical_facts":{"dc:contributor.department":["Mining and Minerals Engineering"],"dc:creator":["Mankosa, Michael James"],"dc:date.accepted":["2009-03-12"],"dc:date.accessioned":["2014-03-14T20:32:35Z"],"dc:date.available":["2014-03-14T20:32:35Z","2009-03-12"],"dc:date.issued":["1986"],"dc:date.submitted":["2009-03-12"],"dc:description.abstract":["As a prerequisite to producing super-clean coal with any physical coal cleaning process, such as microbubble flotation, the feed coal must be micronized to liberate the finely disseminated mineral matter. The stirred ball mill is regarded as one of the most efficient devices for micronizing coal. Using a five-inch batch mill, the optimum operating conditions have been determined in terms of media size, feed size, media type, stirring speed and percent solids. The rates of breakage determined with monosized feeds are compared on the basis of specific energy consumption. It has been found that a 20:1 ball size/particle size ratio gives optimum grinding conditions. With the fine particle sizes obtained using stirred ball milling, as well as other fine grinding techniques, a growing concern has been generated regarding the accuracy of these size distributions. An automated technique has been developed in which a complete mass balanced size distribution can be obtained using an Elzone® 80XY particle size analyzer. A computer program is used to blend the data from successively smaller Orifice tubes, as well as, to determine the weight percent of material in a particle size distribution finer than the lower detection limit of the analyzer. This result is then used to correct the distribution for the missing fine material."],"dc:description.degree":["Master of Science"],"dc:format.extent":["ix, 123 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03122009-040831"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-03122009-040831/"],"dc:identifier.uri":["http://hdl.handle.net/10919/31456"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1986.M3664.pdf"],"dc:relation.isformatof":["OCLC# 15285823"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1986.M3664"],"dc:subject.lcsh":["Coal balls","Grinding machines"],"dc:title":["Investigation of operating conditions in stirred ball milling of coal"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mining and Minerals Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:16:46Z"}