{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/37746"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/37746","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Packed capillary columns for liquid chromatography","abstract":"The advantages and disadvantages of packed capillary columns for high performance liquid chromatography are examined. Historically, the advantages are smaller sample and phase consumption, enhancement in sensitivity, easy column synthesis, higher obtainable efficiency, and easier interfacing to other techniques. These points are explored through experiments in microbore ion chromatography, packed fused silica columns, and capillary zone electrophoresis. These studies also address the disadvantages of microscale HPLC which are stringent instrument design, brittle or weak columns, poor column stability, and the lack of commercial instrumentation. The results of these investigations indicate the following. First, the purported sensitivity enhancement is really attributable to solute focusing and not to column miniaturization. Second, column synthesis is still a difficult procedure that requires experience. Third, higher efficiencies are realized, especially when the column diameter to particle diameter ratio is optimized. Fourth, interfacing to other techniques is simplified because of the lower volumetric flow rates. Finally, the only real disadvantages are stringent instrument design and brittle columns in some instances. This thesis offers means for circumventing these difficulties.","abstract_html":"The advantages and disadvantages of packed capillary columns for high performance liquid chromatography are examined. Historically, the advantages are smaller sample and phase consumption, enhancement in sensitivity, easy column synthesis, higher obtainable efficiency, and easier interfacing to other techniques. These points are explored through experiments in microbore ion chromatography, packed fused silica columns, and capillary zone electrophoresis. These studies also address the disadvantages of microscale HPLC which are stringent instrument design, brittle or weak columns, poor column stability, and the lack of commercial instrumentation. The results of these investigations indicate the following. First, the purported sensitivity enhancement is really attributable to solute focusing and not to column miniaturization. Second, column synthesis is still a difficult procedure that requires experience. Third, higher efficiencies are realized, especially when the column diameter to particle diameter ratio is optimized. Fourth, interfacing to other techniques is simplified because of the lower volumetric flow rates. Finally, the only real disadvantages are stringent instrument design and brittle columns in some instances. This thesis offers means for circumventing these difficulties.","abstract_has_math":false,"creators":["Wilson, William Henry"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Chemistry","degree_department":"Chemistry","school":null,"contributors":[],"advisors":[],"committee_chairs":["McNair, Harold M."],"committee_members":["Taylor, Larry T.","Anderson, M.","Wightman, James P.","Gibson, Harry W."],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-18T20:24:58Z","subjects":["Liquid chromatography -- Research"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05112006-154753"],"render_values":[{"text":"etd-05112006-154753","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-05112006-154753/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-05112006-154753/","href":"http://scholar.lib.vt.edu/theses/available/etd-05112006-154753/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/37746","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/37746","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F37746","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["McNair, Harold M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Taylor, Larry T.","Anderson, M.","Wightman, James P.","Gibson, Harry W."]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry"]},{"key":"dc:creator","label":"Author","values":["Wilson, William Henry"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2006-05-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:10:52Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:10:52Z","2006-05-11"]},{"key":"dc:date.issued","label":"Date","values":["1990"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2006-05-11"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V856_1990.W567.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 23716329"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V856 1990.W567"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Liquid chromatography -- Research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05112006-154753"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-05112006-154753/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/37746"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The advantages and disadvantages of packed capillary columns for high performance liquid chromatography are examined. Historically, the advantages are smaller sample and phase consumption, enhancement in sensitivity, easy column synthesis, higher obtainable efficiency, and easier interfacing to other techniques. These points are explored through experiments in microbore ion chromatography, packed fused silica columns, and capillary zone electrophoresis. These studies also address the disadvantages of microscale HPLC which are stringent instrument design, brittle or weak columns, poor column stability, and the lack of commercial instrumentation. The results of these investigations indicate the following. First, the purported sensitivity enhancement is really attributable to solute focusing and not to column miniaturization. Second, column synthesis is still a difficult procedure that requires experience. Third, higher efficiencies are realized, especially when the column diameter to particle diameter ratio is optimized. Fourth, interfacing to other techniques is simplified because of the lower volumetric flow rates. Finally, the only real disadvantages are stringent instrument design and brittle columns in some instances. This thesis offers means for circumventing these difficulties."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["x, 149 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Packed capillary columns for liquid chromatography"]}]}],"canonical_facts":{"dc:contributor.committeechair":["McNair, Harold M."],"dc:contributor.committeemember":["Taylor, Larry T.","Anderson, M.","Wightman, James P.","Gibson, Harry W."],"dc:contributor.department":["Chemistry"],"dc:creator":["Wilson, William Henry"],"dc:date.accepted":["2006-05-11"],"dc:date.accessioned":["2014-03-14T21:10:52Z"],"dc:date.available":["2014-03-14T21:10:52Z","2006-05-11"],"dc:date.issued":["1990"],"dc:date.submitted":["2006-05-11"],"dc:description.abstract":["The advantages and disadvantages of packed capillary columns for high performance liquid chromatography are examined. Historically, the advantages are smaller sample and phase consumption, enhancement in sensitivity, easy column synthesis, higher obtainable efficiency, and easier interfacing to other techniques. These points are explored through experiments in microbore ion chromatography, packed fused silica columns, and capillary zone electrophoresis. These studies also address the disadvantages of microscale HPLC which are stringent instrument design, brittle or weak columns, poor column stability, and the lack of commercial instrumentation. The results of these investigations indicate the following. First, the purported sensitivity enhancement is really attributable to solute focusing and not to column miniaturization. Second, column synthesis is still a difficult procedure that requires experience. Third, higher efficiencies are realized, especially when the column diameter to particle diameter ratio is optimized. Fourth, interfacing to other techniques is simplified because of the lower volumetric flow rates. Finally, the only real disadvantages are stringent instrument design and brittle columns in some instances. This thesis offers means for circumventing these difficulties."],"dc:description.degree":["Ph. D."],"dc:format.extent":["x, 149 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-05112006-154753"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-05112006-154753/"],"dc:identifier.uri":["http://hdl.handle.net/10919/37746"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V856_1990.W567.pdf"],"dc:relation.isformatof":["OCLC# 23716329"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V856 1990.W567"],"dc:subject.lcsh":["Liquid chromatography -- Research"],"dc:title":["Packed capillary columns for liquid chromatography"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:24:58Z"}