{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/37825"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/37825","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Intensity distribution in cylindrical and bowl shaped transducers and sono-dialysis of a caustic solution","abstract":"In ultrasonic processing, it has been a practice to measure intensity of ultrasonics as a product of plate current and voltage as indicated on ultra sonic generator. At low frequencies the standard equipment is available, such as the sound level meter, to measure the absolute intensity, but at higher frequencies the problem becomes complicated by the diffraction effects on account of the size of the measuring device. In this investigation an attempt has been made to construct a measuring device (called the probe) to measure intensity. A small barium titanate cylindrical element (1/16 inch in diameter and 1/16 inch length) was used as a detector-convertor of sonic pressures. The alternating voltages thus produced were indicated by a vacuum tube voltmeter. This element was cemented in a hypodermic needle in turn was held in a lucite rod (1/2 inch in diameter and five inches in length) which served as a holder. This arrangement was used to probe the sonic fields of cylindrical and bowl shaped transducers.","abstract_html":"In ultrasonic processing, it has been a practice to measure intensity of ultrasonics as a product of plate current and voltage as indicated on ultra sonic generator. At low frequencies the standard equipment is available, such as the sound level meter, to measure the absolute intensity, but at higher frequencies the problem becomes complicated by the diffraction effects on account of the size of the measuring device. In this investigation an attempt has been made to construct a measuring device (called the probe) to measure intensity. A small barium titanate cylindrical element (1/16 inch in diameter and 1/16 inch length) was used as a detector-convertor of sonic pressures. The alternating voltages thus produced were indicated by a vacuum tube voltmeter. This element was cemented in a hypodermic needle in turn was held in a lucite rod (1/2 inch in diameter and five inches in length) which served as a holder. This arrangement was used to probe the sonic fields of cylindrical and bowl shaped transducers.","abstract_has_math":false,"creators":["Bakhshi, Narendra Nath"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Chemical Engineering","degree_department":"Chemical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Vilbrandt, Frank C."],"committee_members":["Bull, Fred W.","Hall, Thomas W.","Loh, H. Y."],"year":1956,"date_issued":"1956-07-09","date_published":"1956-07-09","updated_at":"2026-11-18T20:02:26Z","subjects":["Transducers -- Research"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05192010-020145"],"render_values":[{"text":"etd-05192010-020145","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-05192010-020145/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-05192010-020145/","href":"http://scholar.lib.vt.edu/theses/available/etd-05192010-020145/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/37825","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/37825","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F37825","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Vilbrandt, Frank C."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bull, Fred W.","Hall, Thomas W.","Loh, H. Y."]},{"key":"dc:contributor.department","label":"Department","values":["Chemical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bakhshi, Narendra Nath"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2010-05-19"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:11:08Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:11:08Z","2010-05-19"]},{"key":"dc:date.issued","label":"Date","values":["1956-07-09"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2010-05-19"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V856_1956.B345.pdf","LD5655.V856_1956.B345_drw04.pdf","LD5655.V856_1956.B345_drw02.pdf","LD5655.V856_1956.B345_drw03.pdf","LD5655.V856_1956.B345_drw01.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 20471131"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V856 1956.B345"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Transducers -- Research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05192010-020145"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-05192010-020145/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/37825"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In ultrasonic processing, it has been a practice to measure intensity of ultrasonics as a product of plate current and voltage as indicated on ultra sonic generator. At low frequencies the standard equipment is available, such as the sound level meter, to measure the absolute intensity, but at higher frequencies the problem becomes complicated by the diffraction effects on account of the size of the measuring device. In this investigation an attempt has been made to construct a measuring device (called the probe) to measure intensity. A small barium titanate cylindrical element (1/16 inch in diameter and 1/16 inch length) was used as a detector-convertor of sonic pressures. The alternating voltages thus produced were indicated by a vacuum tube voltmeter. This element was cemented in a hypodermic needle in turn was held in a lucite rod (1/2 inch in diameter and five inches in length) which served as a holder. This arrangement was used to probe the sonic fields of cylindrical and bowl shaped transducers."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiii, 257 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Intensity distribution in cylindrical and bowl shaped transducers and sono-dialysis of a caustic solution"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Vilbrandt, Frank C."],"dc:contributor.committeemember":["Bull, Fred W.","Hall, Thomas W.","Loh, H. Y."],"dc:contributor.department":["Chemical Engineering"],"dc:creator":["Bakhshi, Narendra Nath"],"dc:date.accepted":["2010-05-19"],"dc:date.accessioned":["2014-03-14T21:11:08Z"],"dc:date.available":["2014-03-14T21:11:08Z","2010-05-19"],"dc:date.issued":["1956-07-09"],"dc:date.submitted":["2010-05-19"],"dc:description.abstract":["In ultrasonic processing, it has been a practice to measure intensity of ultrasonics as a product of plate current and voltage as indicated on ultra sonic generator. At low frequencies the standard equipment is available, such as the sound level meter, to measure the absolute intensity, but at higher frequencies the problem becomes complicated by the diffraction effects on account of the size of the measuring device. In this investigation an attempt has been made to construct a measuring device (called the probe) to measure intensity. A small barium titanate cylindrical element (1/16 inch in diameter and 1/16 inch length) was used as a detector-convertor of sonic pressures. The alternating voltages thus produced were indicated by a vacuum tube voltmeter. This element was cemented in a hypodermic needle in turn was held in a lucite rod (1/2 inch in diameter and five inches in length) which served as a holder. This arrangement was used to probe the sonic fields of cylindrical and bowl shaped transducers."],"dc:description.degree":["Ph. D."],"dc:format.extent":["xiii, 257 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-05192010-020145"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-05192010-020145/"],"dc:identifier.uri":["http://hdl.handle.net/10919/37825"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V856_1956.B345.pdf","LD5655.V856_1956.B345_drw04.pdf","LD5655.V856_1956.B345_drw02.pdf","LD5655.V856_1956.B345_drw03.pdf","LD5655.V856_1956.B345_drw01.pdf"],"dc:relation.isformatof":["OCLC# 20471131"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V856 1956.B345"],"dc:subject.lcsh":["Transducers -- Research"],"dc:title":["Intensity distribution in cylindrical and bowl shaped transducers and sono-dialysis of a caustic solution"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemical Engineering"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute"]},"updated_at":"2026-11-18T20:02:26Z"}