{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/38948"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/38948","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Birefringent single-arm fiber optic enthalpimeter for catalytic reaction monitoring","abstract":"Changes in heat content are almost universally associated with chemical reactions. Thermometry as an analytical tool has been extensively researched and developed. Finding solutions to problems involving thermal isolation, specificity, sensitivity, and cross-sensitivity remain as active areas of interest. Fiberoptic interferometers, which use phase phenomena associated with propagating light, are extremely sensitive to heat. This research has focused on a special \"birefringent\" optical fiber. Two channels of information are generated in this single-fiber interferometer which correspond to the heat evolved from a catalytic reaction isolated on the fiber surface. Because of the unique transduction mechanism associated with the \"birefringent\" optical fiber, this device is sensitive to heat and remarkably insensitive to pressure. Details of the characterization and development of the birefringent optical fiber into a useful analytical probe are presented.","abstract_html":"Changes in heat content are almost universally associated with chemical reactions. Thermometry as an analytical tool has been extensively researched and developed. Finding solutions to problems involving thermal isolation, specificity, sensitivity, and cross-sensitivity remain as active areas of interest. Fiberoptic interferometers, which use phase phenomena associated with propagating light, are extremely sensitive to heat. This research has focused on a special &quot;birefringent&quot; optical fiber. Two channels of information are generated in this single-fiber interferometer which correspond to the heat evolved from a catalytic reaction isolated on the fiber surface. Because of the unique transduction mechanism associated with the &quot;birefringent&quot; optical fiber, this device is sensitive to heat and remarkably insensitive to pressure. Details of the characterization and development of the birefringent optical fiber into a useful analytical probe are presented.","abstract_has_math":false,"creators":["Richmond, Eric William"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Analytical Chemistry","degree_department":"Analytical Chemistry","school":null,"contributors":[],"advisors":[],"committee_chairs":["Dessy, Raymond E."],"committee_members":["Long, Gary L.","Mason, John G.","McNair, Harold M.","Wightman, James P."],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-18T20:17:20Z","subjects":["Fiber optics","Optical fibers"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07282008-135248"],"render_values":[{"text":"etd-07282008-135248","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-07282008-135248/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-07282008-135248/","href":"http://scholar.lib.vt.edu/theses/available/etd-07282008-135248/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/38948","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/38948","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F38948","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Dessy, Raymond E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Long, Gary L.","Mason, John G.","McNair, Harold M.","Wightman, James P."]},{"key":"dc:contributor.department","label":"Department","values":["Analytical Chemistry"]},{"key":"dc:creator","label":"Author","values":["Richmond, Eric William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2008-07-28"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:16:45Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:16:45Z","2008-07-28"]},{"key":"dc:date.issued","label":"Date","values":["1990"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2008-07-28"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V856_1990.R536.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 23663441"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Analytical Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V856 1990.R536"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Fiber optics","Optical fibers"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07282008-135248"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-07282008-135248/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/38948"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Changes in heat content are almost universally associated with chemical reactions. Thermometry as an analytical tool has been extensively researched and developed. Finding solutions to problems involving thermal isolation, specificity, sensitivity, and cross-sensitivity remain as active areas of interest. Fiberoptic interferometers, which use phase phenomena associated with propagating light, are extremely sensitive to heat. This research has focused on a special \"birefringent\" optical fiber. Two channels of information are generated in this single-fiber interferometer which correspond to the heat evolved from a catalytic reaction isolated on the fiber surface. Because of the unique transduction mechanism associated with the \"birefringent\" optical fiber, this device is sensitive to heat and remarkably insensitive to pressure. Details of the characterization and development of the birefringent optical fiber into a useful analytical probe are presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vi, 137 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Birefringent single-arm fiber optic enthalpimeter for catalytic reaction monitoring"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Dessy, Raymond E."],"dc:contributor.committeemember":["Long, Gary L.","Mason, John G.","McNair, Harold M.","Wightman, James P."],"dc:contributor.department":["Analytical Chemistry"],"dc:creator":["Richmond, Eric William"],"dc:date.accepted":["2008-07-28"],"dc:date.accessioned":["2014-03-14T21:16:45Z"],"dc:date.available":["2014-03-14T21:16:45Z","2008-07-28"],"dc:date.issued":["1990"],"dc:date.submitted":["2008-07-28"],"dc:description.abstract":["Changes in heat content are almost universally associated with chemical reactions. Thermometry as an analytical tool has been extensively researched and developed. Finding solutions to problems involving thermal isolation, specificity, sensitivity, and cross-sensitivity remain as active areas of interest. Fiberoptic interferometers, which use phase phenomena associated with propagating light, are extremely sensitive to heat. This research has focused on a special \"birefringent\" optical fiber. Two channels of information are generated in this single-fiber interferometer which correspond to the heat evolved from a catalytic reaction isolated on the fiber surface. Because of the unique transduction mechanism associated with the \"birefringent\" optical fiber, this device is sensitive to heat and remarkably insensitive to pressure. Details of the characterization and development of the birefringent optical fiber into a useful analytical probe are presented."],"dc:description.degree":["Ph. D."],"dc:format.extent":["vi, 137 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-07282008-135248"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-07282008-135248/"],"dc:identifier.uri":["http://hdl.handle.net/10919/38948"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V856_1990.R536.pdf"],"dc:relation.isformatof":["OCLC# 23663441"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V856 1990.R536"],"dc:subject.lcsh":["Fiber optics","Optical fibers"],"dc:title":["Birefringent single-arm fiber optic enthalpimeter for catalytic reaction monitoring"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Analytical Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:17:20Z"}