{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/39556"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/39556","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Development and evaluation of an acylating agent detector using surface acoustic wave devices","abstract":"The monitoring of harmful ambient vapors is of major concern in the industrial environment. To this end, the development of systems which detect and respond in real time to specific vapors is a highly desirable goal. Surface Acoustic Wave (SAW) devices have been used for chemical analysis since 1978. While sensitive to mass changes occurring on their surfaces, they are not selective to the mass they will detect. Their use as chemical sensors requires the development of specificity for a vapor (or class of vapors) using selective chemical reagents suspended in film media that can have their permeability easily changed. This dissertation presents the development of an automated dosimeter for the detection of phosgene using SAW devices. By changing the film media from a very permeable material to a film exhibiting less permeability, the analytical range of the device using the same suspended selective chemical reagent is expanded to concentrations which the very permeable film is incapable of accurately measuring.","abstract_html":"The monitoring of harmful ambient vapors is of major concern in the industrial environment. To this end, the development of systems which detect and respond in real time to specific vapors is a highly desirable goal. Surface Acoustic Wave (SAW) devices have been used for chemical analysis since 1978. While sensitive to mass changes occurring on their surfaces, they are not selective to the mass they will detect. Their use as chemical sensors requires the development of specificity for a vapor (or class of vapors) using selective chemical reagents suspended in film media that can have their permeability easily changed. This dissertation presents the development of an automated dosimeter for the detection of phosgene using SAW devices. By changing the film media from a very permeable material to a film exhibiting less permeability, the analytical range of the device using the same suspended selective chemical reagent is expanded to concentrations which the very permeable film is incapable of accurately measuring.","abstract_has_math":false,"creators":["Wollenberg, Glen David"],"institution":"Virginia Tech","degree_name":"Ph. D.","degree_level":"doctoral","degree_discipline":"Chemistry","degree_department":"Chemistry","school":null,"contributors":[],"advisors":[],"committee_chairs":["Dessy, Raymond E."],"committee_members":["Anderson, Mark R.","Mason, John G.","Tanko, James M.","Ward, Thomas C."],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-18T20:13:35Z","subjects":["Acoustic surface wave devices","Gas detectors -- Design"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10032007-171625"],"render_values":[{"text":"etd-10032007-171625","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-10032007-171625/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-10032007-171625/","href":"http://scholar.lib.vt.edu/theses/available/etd-10032007-171625/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/39556","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/39556","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F39556","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Dessy, Raymond E."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Anderson, Mark R.","Mason, John G.","Tanko, James M.","Ward, Thomas C."]},{"key":"dc:contributor.department","label":"Department","values":["Chemistry"]},{"key":"dc:creator","label":"Author","values":["Wollenberg, Glen David"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2007-10-03"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:19:37Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:19:37Z","2007-10-03"]},{"key":"dc:date.issued","label":"Date","values":["1992"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2007-10-03"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V856_1992.W644.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 26064304"]},{"key":"dc:type","label":"Dc Type","values":["Dissertation"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["doctoral"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Ph. D."]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V856 1992.W644"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Acoustic surface wave devices","Gas detectors -- Design"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10032007-171625"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-10032007-171625/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/39556"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The monitoring of harmful ambient vapors is of major concern in the industrial environment. To this end, the development of systems which detect and respond in real time to specific vapors is a highly desirable goal. Surface Acoustic Wave (SAW) devices have been used for chemical analysis since 1978. While sensitive to mass changes occurring on their surfaces, they are not selective to the mass they will detect. Their use as chemical sensors requires the development of specificity for a vapor (or class of vapors) using selective chemical reagents suspended in film media that can have their permeability easily changed. This dissertation presents the development of an automated dosimeter for the detection of phosgene using SAW devices. By changing the film media from a very permeable material to a film exhibiting less permeability, the analytical range of the device using the same suspended selective chemical reagent is expanded to concentrations which the very permeable film is incapable of accurately measuring."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Ph. D."]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xvi, 263 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Development and evaluation of an acylating agent detector using surface acoustic wave devices"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Dessy, Raymond E."],"dc:contributor.committeemember":["Anderson, Mark R.","Mason, John G.","Tanko, James M.","Ward, Thomas C."],"dc:contributor.department":["Chemistry"],"dc:creator":["Wollenberg, Glen David"],"dc:date.accepted":["2007-10-03"],"dc:date.accessioned":["2014-03-14T21:19:37Z"],"dc:date.available":["2014-03-14T21:19:37Z","2007-10-03"],"dc:date.issued":["1992"],"dc:date.submitted":["2007-10-03"],"dc:description.abstract":["The monitoring of harmful ambient vapors is of major concern in the industrial environment. To this end, the development of systems which detect and respond in real time to specific vapors is a highly desirable goal. Surface Acoustic Wave (SAW) devices have been used for chemical analysis since 1978. While sensitive to mass changes occurring on their surfaces, they are not selective to the mass they will detect. Their use as chemical sensors requires the development of specificity for a vapor (or class of vapors) using selective chemical reagents suspended in film media that can have their permeability easily changed. This dissertation presents the development of an automated dosimeter for the detection of phosgene using SAW devices. By changing the film media from a very permeable material to a film exhibiting less permeability, the analytical range of the device using the same suspended selective chemical reagent is expanded to concentrations which the very permeable film is incapable of accurately measuring."],"dc:description.degree":["Ph. D."],"dc:format.extent":["xvi, 263 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-10032007-171625"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-10032007-171625/"],"dc:identifier.uri":["http://hdl.handle.net/10919/39556"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V856_1992.W644.pdf"],"dc:relation.isformatof":["OCLC# 26064304"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V856 1992.W644"],"dc:subject.lcsh":["Acoustic surface wave devices","Gas detectors -- Design"],"dc:title":["Development and evaluation of an acylating agent detector using surface acoustic wave devices"],"dc:type":["Dissertation"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Chemistry"],"thesis:degree_level":["doctoral"],"thesis:degree_name":["Ph. D."],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:13:35Z"}