{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/40748"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/40748","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Standoff screws functioning as mechanical shear connectors in composite joists","abstract":"The results of sixty-five double-sided pushout tests utilizing the Elco grade 8, 5/16 in. diameter, standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied test parameters include: steel deck profile, base angle thickness, screw embedment depth, slab thickness, and slab width. The objectives of the testing were (1) to provide an understanding of the strength of the standoff screw in various test geometries and (2) to provide an understanding of the slip characteristics, or ductility, of the connector. A review of literature presents several applicable existing welded stud strength models based on post-test observations of failure mechanisms. Modeled failure mechanisms include: concrete splitting, concrete pullout, rib shear, and stud shear. After applying the existing models to the pushout test data, the following conclusions are drawn: (1) the concrete splitting model developed by Oehlers (1989) can be used to predict the strength of the standoff screw in flat slab geometries and (2) no existing model adequately predicts the strength of the standoff screw in geometries utilizing profiled steel deck. An equation, based on a rederivation of a wedged shaped shear-cone pullout model (Lloyd & Wright 1990), is presented which predicts the strength of the standoff screw in geometries with steel deck with acceptable accuracy.","abstract_html":"The results of sixty-five double-sided pushout tests utilizing the Elco grade 8, 5/16 in. diameter, standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied test parameters include: steel deck profile, base angle thickness, screw embedment depth, slab thickness, and slab width. The objectives of the testing were (1) to provide an understanding of the strength of the standoff screw in various test geometries and (2) to provide an understanding of the slip characteristics, or ductility, of the connector. A review of literature presents several applicable existing welded stud strength models based on post-test observations of failure mechanisms. Modeled failure mechanisms include: concrete splitting, concrete pullout, rib shear, and stud shear. After applying the existing models to the pushout test data, the following conclusions are drawn: (1) the concrete splitting model developed by Oehlers (1989) can be used to predict the strength of the standoff screw in flat slab geometries and (2) no existing model adequately predicts the strength of the standoff screw in geometries utilizing profiled steel deck. An equation, based on a rederivation of a wedged shaped shear-cone pullout model (Lloyd &amp; Wright 1990), is presented which predicts the strength of the standoff screw in geometries with steel deck with acceptable accuracy.","abstract_has_math":false,"creators":["Hankins, Steven C."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Easterling, William Samuel"],"committee_members":["Barker, Richard M.","Murray, Thomas M."],"year":1994,"date_issued":"1994-08-15","date_published":"1994-08-15","updated_at":"2026-11-18T20:06:45Z","subjects":["Composite construction","Screws","Steel joists"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01242009-063249"],"render_values":[{"text":"etd-01242009-063249","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-01242009-063249/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-01242009-063249/","href":"http://scholar.lib.vt.edu/theses/available/etd-01242009-063249/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/40748","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/40748","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F40748","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Easterling, William Samuel"]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Barker, Richard M.","Murray, Thomas M."]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Hankins, Steven C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-01-24"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:27:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:27:43Z","2009-01-24"]},{"key":"dc:date.issued","label":"Date","values":["1994-08-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-01-24"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1994.H366.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 31459276"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1994.H366"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Composite construction","Screws","Steel joists"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01242009-063249"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-01242009-063249/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/40748"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The results of sixty-five double-sided pushout tests utilizing the Elco grade 8, 5/16 in. diameter, standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied test parameters include: steel deck profile, base angle thickness, screw embedment depth, slab thickness, and slab width. The objectives of the testing were (1) to provide an understanding of the strength of the standoff screw in various test geometries and (2) to provide an understanding of the slip characteristics, or ductility, of the connector. A review of literature presents several applicable existing welded stud strength models based on post-test observations of failure mechanisms. Modeled failure mechanisms include: concrete splitting, concrete pullout, rib shear, and stud shear. After applying the existing models to the pushout test data, the following conclusions are drawn: (1) the concrete splitting model developed by Oehlers (1989) can be used to predict the strength of the standoff screw in flat slab geometries and (2) no existing model adequately predicts the strength of the standoff screw in geometries utilizing profiled steel deck. An equation, based on a rederivation of a wedged shaped shear-cone pullout model (Lloyd & Wright 1990), is presented which predicts the strength of the standoff screw in geometries with steel deck with acceptable accuracy."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xii, 325 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Standoff screws functioning as mechanical shear connectors in composite joists"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Easterling, William Samuel"],"dc:contributor.committeemember":["Barker, Richard M.","Murray, Thomas M."],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Hankins, Steven C."],"dc:date.accepted":["2009-01-24"],"dc:date.accessioned":["2014-03-14T21:27:43Z"],"dc:date.available":["2014-03-14T21:27:43Z","2009-01-24"],"dc:date.issued":["1994-08-15"],"dc:date.submitted":["2009-01-24"],"dc:description.abstract":["The results of sixty-five double-sided pushout tests utilizing the Elco grade 8, 5/16 in. diameter, standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied test parameters include: steel deck profile, base angle thickness, screw embedment depth, slab thickness, and slab width. The objectives of the testing were (1) to provide an understanding of the strength of the standoff screw in various test geometries and (2) to provide an understanding of the slip characteristics, or ductility, of the connector. A review of literature presents several applicable existing welded stud strength models based on post-test observations of failure mechanisms. Modeled failure mechanisms include: concrete splitting, concrete pullout, rib shear, and stud shear. After applying the existing models to the pushout test data, the following conclusions are drawn: (1) the concrete splitting model developed by Oehlers (1989) can be used to predict the strength of the standoff screw in flat slab geometries and (2) no existing model adequately predicts the strength of the standoff screw in geometries utilizing profiled steel deck. An equation, based on a rederivation of a wedged shaped shear-cone pullout model (Lloyd & Wright 1990), is presented which predicts the strength of the standoff screw in geometries with steel deck with acceptable accuracy."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xii, 325 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-01242009-063249"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-01242009-063249/"],"dc:identifier.uri":["http://hdl.handle.net/10919/40748"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1994.H366.pdf"],"dc:relation.isformatof":["OCLC# 31459276"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1994.H366"],"dc:subject.lcsh":["Composite construction","Screws","Steel joists"],"dc:title":["Standoff screws functioning as mechanical shear connectors in composite joists"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:06:45Z"}