{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/40762"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/40762","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Determining optimal load for a constant-load cycle ergometer test relative to isotonic leg strength","abstract":"This study investigated the determination of an optimal resistive force for use during a short-term, high-intensity cycling power test. Twenty-four college females [age (yrs) x̄=22.0 ± 0.50; weight (kg) x̄=60.3 ± 1.46] gave consent and participated in a 1 repetition maximum (RM) test of the leg extensors and 5 maximal 15 s cycling tests using a modified Monark cycle ergometer. The 1 RM test was performed using a Nautilus leg extensor machine. Even increments between six to ten % 1RM test were utilized to determine the resistive force applied to the flywheel. The 5 tests were divided into a 2 testing sessions occurring at least 48 h apart. Each subject warmed-up at 50 - 60 rpms for 2 - 5 minutes without resistance prior to testing. Each test consisted of a maximal cycling bout of 15 s with 20 minutes rest between tests. The variables measured included peak power (PP), time to peak power (TTPP), power fatigue rate (PFR), power fatigue index (PFI), and average power (AP). These values were collected by a microcomputer interfaced with the cycle ergometer. In general, PP decreased at a resistance greater than 9 % 1RM. The average reported PP values were 363±15, 413±19, 465±19, 520±21, and 460±41 for loads 6 to 10 % 1RM respectively. Similar results were reported for AP. The differences in PP for loads between 8 and 10 % 1RM were statistically different. Results show that PP varies based on loads of % 1RM and the optimal range is between 8 and 10% 1RM.","abstract_html":"This study investigated the determination of an optimal resistive force for use during a short-term, high-intensity cycling power test. Twenty-four college females [age (yrs) x̄=22.0 ± 0.50; weight (kg) x̄=60.3 ± 1.46] gave consent and participated in a 1 repetition maximum (RM) test of the leg extensors and 5 maximal 15 s cycling tests using a modified Monark cycle ergometer. The 1 RM test was performed using a Nautilus leg extensor machine. Even increments between six to ten % 1RM test were utilized to determine the resistive force applied to the flywheel. The 5 tests were divided into a 2 testing sessions occurring at least 48 h apart. Each subject warmed-up at 50 - 60 rpms for 2 - 5 minutes without resistance prior to testing. Each test consisted of a maximal cycling bout of 15 s with 20 minutes rest between tests. The variables measured included peak power (PP), time to peak power (TTPP), power fatigue rate (PFR), power fatigue index (PFI), and average power (AP). These values were collected by a microcomputer interfaced with the cycle ergometer. In general, PP decreased at a resistance greater than 9 % 1RM. The average reported PP values were 363±15, 413±19, 465±19, 520±21, and 460±41 for loads 6 to 10 % 1RM respectively. Similar results were reported for AP. The differences in PP for loads between 8 and 10 % 1RM were statistically different. Results show that PP varies based on loads of % 1RM and the optimal range is between 8 and 10% 1RM.","abstract_has_math":false,"creators":["Wagner, Holly A."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Exercise Physiology","degree_department":"Exercise Physiology","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-18T20:15:00Z","subjects":["Cycling","Dynamometer","Isometric exercise","Leg","Muscle strength"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01242009-063426"],"render_values":[{"text":"etd-01242009-063426","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-01242009-063426/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-01242009-063426/","href":"http://scholar.lib.vt.edu/theses/available/etd-01242009-063426/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/40762","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/40762","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F40762","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Exercise Physiology"]},{"key":"dc:creator","label":"Author","values":["Wagner, Holly A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-01-24"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:27:46Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:27:46Z","2009-01-24"]},{"key":"dc:date.issued","label":"Date","values":["1992"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-01-24"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1992.W346.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 26613484"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Exercise Physiology"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1992.W346"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Cycling","Dynamometer","Isometric exercise","Leg","Muscle strength"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01242009-063426"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-01242009-063426/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/40762"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study investigated the determination of an optimal resistive force for use during a short-term, high-intensity cycling power test. Twenty-four college females [age (yrs) x̄=22.0 ± 0.50; weight (kg) x̄=60.3 ± 1.46] gave consent and participated in a 1 repetition maximum (RM) test of the leg extensors and 5 maximal 15 s cycling tests using a modified Monark cycle ergometer. The 1 RM test was performed using a Nautilus leg extensor machine. Even increments between six to ten % 1RM test were utilized to determine the resistive force applied to the flywheel. The 5 tests were divided into a 2 testing sessions occurring at least 48 h apart. Each subject warmed-up at 50 - 60 rpms for 2 - 5 minutes without resistance prior to testing. Each test consisted of a maximal cycling bout of 15 s with 20 minutes rest between tests. The variables measured included peak power (PP), time to peak power (TTPP), power fatigue rate (PFR), power fatigue index (PFI), and average power (AP). These values were collected by a microcomputer interfaced with the cycle ergometer. In general, PP decreased at a resistance greater than 9 % 1RM. The average reported PP values were 363±15, 413±19, 465±19, 520±21, and 460±41 for loads 6 to 10 % 1RM respectively. Similar results were reported for AP. The differences in PP for loads between 8 and 10 % 1RM were statistically different. Results show that PP varies based on loads of % 1RM and the optimal range is between 8 and 10% 1RM."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vi, 104 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Determining optimal load for a constant-load cycle ergometer test relative to isotonic leg strength"]}]}],"canonical_facts":{"dc:contributor.department":["Exercise Physiology"],"dc:creator":["Wagner, Holly A."],"dc:date.accepted":["2009-01-24"],"dc:date.accessioned":["2014-03-14T21:27:46Z"],"dc:date.available":["2014-03-14T21:27:46Z","2009-01-24"],"dc:date.issued":["1992"],"dc:date.submitted":["2009-01-24"],"dc:description.abstract":["This study investigated the determination of an optimal resistive force for use during a short-term, high-intensity cycling power test. Twenty-four college females [age (yrs) x̄=22.0 ± 0.50; weight (kg) x̄=60.3 ± 1.46] gave consent and participated in a 1 repetition maximum (RM) test of the leg extensors and 5 maximal 15 s cycling tests using a modified Monark cycle ergometer. The 1 RM test was performed using a Nautilus leg extensor machine. Even increments between six to ten % 1RM test were utilized to determine the resistive force applied to the flywheel. The 5 tests were divided into a 2 testing sessions occurring at least 48 h apart. Each subject warmed-up at 50 - 60 rpms for 2 - 5 minutes without resistance prior to testing. Each test consisted of a maximal cycling bout of 15 s with 20 minutes rest between tests. The variables measured included peak power (PP), time to peak power (TTPP), power fatigue rate (PFR), power fatigue index (PFI), and average power (AP). These values were collected by a microcomputer interfaced with the cycle ergometer. In general, PP decreased at a resistance greater than 9 % 1RM. The average reported PP values were 363±15, 413±19, 465±19, 520±21, and 460±41 for loads 6 to 10 % 1RM respectively. Similar results were reported for AP. The differences in PP for loads between 8 and 10 % 1RM were statistically different. Results show that PP varies based on loads of % 1RM and the optimal range is between 8 and 10% 1RM."],"dc:description.degree":["Master of Science"],"dc:format.extent":["vi, 104 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-01242009-063426"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-01242009-063426/"],"dc:identifier.uri":["http://hdl.handle.net/10919/40762"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1992.W346.pdf"],"dc:relation.isformatof":["OCLC# 26613484"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1992.W346"],"dc:subject.lcsh":["Cycling","Dynamometer","Isometric exercise","Leg","Muscle strength"],"dc:title":["Determining optimal load for a constant-load cycle ergometer test relative to isotonic leg strength"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Exercise Physiology"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:15:00Z"}