{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/40812"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/40812","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Optical pyrometry for noncontact temperature measurement","abstract":"A noncontact two-color pyrometer, which uses an infrared (IR) transmitting rod and IR lenses to optically measure the temperature of a molten particle as it falls in an evacuated drop tube, has been designed and tested in the laboratory and in the field. The design uses a calcium fluoride (CaF₂) rod which transports optical energy radiated from the molten particle to a beam splitter, where it is split into two signals. Each signal is filtered and focused onto an indium antimonide (InSb) photodetector which is liquid nitrogen (LN₂) cooled. A ratio of the detectors' outputs indicates the temperature of the molten particle. In the laboratory, a blackbody calibrator is used as a source, and a shutter with a speed of 4 ms is used to simulate the particle dropping by the optical sensing port. The pyrometer has been calibrated for a particle temperature range of 650°C - 1200°C.","abstract_html":"A noncontact two-color pyrometer, which uses an infrared (IR) transmitting rod and IR lenses to optically measure the temperature of a molten particle as it falls in an evacuated drop tube, has been designed and tested in the laboratory and in the field. The design uses a calcium fluoride (CaF₂) rod which transports optical energy radiated from the molten particle to a beam splitter, where it is split into two signals. Each signal is filtered and focused onto an indium antimonide (InSb) photodetector which is liquid nitrogen (LN₂) cooled. A ratio of the detectors&#x27; outputs indicates the temperature of the molten particle. In the laboratory, a blackbody calibrator is used as a source, and a shutter with a speed of 4 ms is used to simulate the particle dropping by the optical sensing port. The pyrometer has been calibrated for a particle temperature range of 650°C - 1200°C.","abstract_has_math":false,"creators":["Moneyhun, Sara E."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-18T20:28:26Z","subjects":["Pyrometers","Temperature measuring instruments"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01262010-020330"],"render_values":[{"text":"etd-01262010-020330","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-01262010-020330/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-01262010-020330/","href":"http://scholar.lib.vt.edu/theses/available/etd-01262010-020330/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/40812","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/40812","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F40812","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Moneyhun, Sara E."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2010-01-26"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:27:56Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:27:56Z","2010-01-26"]},{"key":"dc:date.issued","label":"Date","values":["1990"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2010-01-26"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1990.M664.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 23663430"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1990.M664"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Pyrometers","Temperature measuring instruments"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-01262010-020330"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-01262010-020330/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/40812"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A noncontact two-color pyrometer, which uses an infrared (IR) transmitting rod and IR lenses to optically measure the temperature of a molten particle as it falls in an evacuated drop tube, has been designed and tested in the laboratory and in the field. The design uses a calcium fluoride (CaF₂) rod which transports optical energy radiated from the molten particle to a beam splitter, where it is split into two signals. Each signal is filtered and focused onto an indium antimonide (InSb) photodetector which is liquid nitrogen (LN₂) cooled. A ratio of the detectors' outputs indicates the temperature of the molten particle. In the laboratory, a blackbody calibrator is used as a source, and a shutter with a speed of 4 ms is used to simulate the particle dropping by the optical sensing port. The pyrometer has been calibrated for a particle temperature range of 650°C - 1200°C."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["v, 64 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optical pyrometry for noncontact temperature measurement"]}]}],"canonical_facts":{"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Moneyhun, Sara E."],"dc:date.accepted":["2010-01-26"],"dc:date.accessioned":["2014-03-14T21:27:56Z"],"dc:date.available":["2014-03-14T21:27:56Z","2010-01-26"],"dc:date.issued":["1990"],"dc:date.submitted":["2010-01-26"],"dc:description.abstract":["A noncontact two-color pyrometer, which uses an infrared (IR) transmitting rod and IR lenses to optically measure the temperature of a molten particle as it falls in an evacuated drop tube, has been designed and tested in the laboratory and in the field. The design uses a calcium fluoride (CaF₂) rod which transports optical energy radiated from the molten particle to a beam splitter, where it is split into two signals. Each signal is filtered and focused onto an indium antimonide (InSb) photodetector which is liquid nitrogen (LN₂) cooled. A ratio of the detectors' outputs indicates the temperature of the molten particle. In the laboratory, a blackbody calibrator is used as a source, and a shutter with a speed of 4 ms is used to simulate the particle dropping by the optical sensing port. The pyrometer has been calibrated for a particle temperature range of 650°C - 1200°C."],"dc:description.degree":["Master of Science"],"dc:format.extent":["v, 64 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-01262010-020330"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-01262010-020330/"],"dc:identifier.uri":["http://hdl.handle.net/10919/40812"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1990.M664.pdf"],"dc:relation.isformatof":["OCLC# 23663430"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1990.M664"],"dc:subject.lcsh":["Pyrometers","Temperature measuring instruments"],"dc:title":["Optical pyrometry for noncontact temperature measurement"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:28:26Z"}