{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/40957"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/40957","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Model for precise detection of bone edges","abstract":"A mathematical model which is used to detect bone edges accurately is described in this thesis. This model is derived by assuming the X-ray source to be a square region. It is shown that for an ideal X-ray source (point source), the bone edge lies exactly at the location of maximum first derivative of the imaged object's transmission function. However, for the non-ideal case, it is shown that the bone edge does not lie at the maximum first derivative location. Also, it is shown that an offset can be calculated from the edge parameters. The Marr- Hildreth edge detector is used to detect the initial estimates for edge location. Precise estimates are obtained by using the facet model. The offset is then calculated and applied to these estimates.","abstract_html":"A mathematical model which is used to detect bone edges accurately is described in this thesis. This model is derived by assuming the X-ray source to be a square region. It is shown that for an ideal X-ray source (point source), the bone edge lies exactly at the location of maximum first derivative of the imaged object&#x27;s transmission function. However, for the non-ideal case, it is shown that the bone edge does not lie at the maximum first derivative location. Also, it is shown that an offset can be calculated from the edge parameters. The Marr- Hildreth edge detector is used to detect the initial estimates for edge location. Precise estimates are obtained by using the facet model. The offset is then calculated and applied to these estimates.","abstract_has_math":false,"creators":["Ramesh, Visvanathan"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Electrical Engineering","degree_department":"Electrical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Ehrich, Roger W.","Barber, Donald L."],"committee_members":["Yu, Kai Bor","Tront, Joseph G."],"year":1987,"date_issued":"1987-02-04","date_published":"1987-02-04","updated_at":"2026-11-18T20:25:39Z","subjects":["Bones -- Radiography","X-ray spectroscopy"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02062013-040221"],"render_values":[{"text":"etd-02062013-040221","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-02062013-040221/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-02062013-040221/","href":"http://scholar.lib.vt.edu/theses/available/etd-02062013-040221/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/40957","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/40957","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F40957","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Ehrich, Roger W.","Barber, Donald L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Yu, Kai Bor","Tront, Joseph G."]},{"key":"dc:contributor.department","label":"Department","values":["Electrical Engineering"]},{"key":"dc:creator","label":"Author","values":["Ramesh, Visvanathan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2013-02-06"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:28:43Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:28:43Z","2013-02-06"]},{"key":"dc:date.issued","label":"Date","values":["1987-02-04"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2013-02-06"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1987.R355.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 16263146"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Electrical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1987.R355"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Bones -- Radiography","X-ray spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-02062013-040221"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-02062013-040221/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/40957"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A mathematical model which is used to detect bone edges accurately is described in this thesis. This model is derived by assuming the X-ray source to be a square region. It is shown that for an ideal X-ray source (point source), the bone edge lies exactly at the location of maximum first derivative of the imaged object's transmission function. However, for the non-ideal case, it is shown that the bone edge does not lie at the maximum first derivative location. Also, it is shown that an offset can be calculated from the edge parameters. The Marr- Hildreth edge detector is used to detect the initial estimates for edge location. Precise estimates are obtained by using the facet model. The offset is then calculated and applied to these estimates."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 102 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Model for precise detection of bone edges"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Ehrich, Roger W.","Barber, Donald L."],"dc:contributor.committeemember":["Yu, Kai Bor","Tront, Joseph G."],"dc:contributor.department":["Electrical Engineering"],"dc:creator":["Ramesh, Visvanathan"],"dc:date.accepted":["2013-02-06"],"dc:date.accessioned":["2014-03-14T21:28:43Z"],"dc:date.available":["2014-03-14T21:28:43Z","2013-02-06"],"dc:date.issued":["1987-02-04"],"dc:date.submitted":["2013-02-06"],"dc:description.abstract":["A mathematical model which is used to detect bone edges accurately is described in this thesis. This model is derived by assuming the X-ray source to be a square region. It is shown that for an ideal X-ray source (point source), the bone edge lies exactly at the location of maximum first derivative of the imaged object's transmission function. However, for the non-ideal case, it is shown that the bone edge does not lie at the maximum first derivative location. Also, it is shown that an offset can be calculated from the edge parameters. The Marr- Hildreth edge detector is used to detect the initial estimates for edge location. Precise estimates are obtained by using the facet model. The offset is then calculated and applied to these estimates."],"dc:description.degree":["Master of Science"],"dc:format.extent":["ix, 102 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-02062013-040221"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-02062013-040221/"],"dc:identifier.uri":["http://hdl.handle.net/10919/40957"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1987.R355.pdf"],"dc:relation.isformatof":["OCLC# 16263146"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1987.R355"],"dc:subject.lcsh":["Bones -- Radiography","X-ray spectroscopy"],"dc:title":["Model for precise detection of bone edges"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Electrical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:25:39Z"}