{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41428"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41428","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Performance measurements of a flashing flow nozzle","abstract":"The performance of a flashing flow nozzle was quantified by efficiency and metastability measurements. Efficiency was calculated over a range of operating conditions, by using both inlet and exit conditions and the nozzle thrust. Metastability was quantified by a parameter that compared the experimental mass flow rate with homogeneous equilibrium and frozen state flow rates. The efficiency of the flashing flow nozzle was found to be less than half the efficiency of the nozzle while operating at near thermodynamic equilibrium. Attempts were made to improve nozzle performance by lowering the piping diameter immediately upstream of the nozzle to increase flow turbulence and encourage a uniform bubbly flow. Bubbly flow helps two-phase flows become less metastable, by generating a uniform distribution of bubbles that act as nucleation sites for flashing inception. Low flow metastabilities were found with high inlet qualities and small upstream piping diameters. These conditions also resulted in the highest flashing flow nozzle efficiencies; however, the efficiency showed a much less pronounced response to upstream piping diameter. The homogeneous equilibrium model was found to be an inaccurate predictor of nozzle performance. To satisfy this model, a shock must be positioned in the nozzle's divergent section, severely limiting nozzle efficiency. The effects of phase slip on nozzle efficiency were investigated with recommendations made for further research in this area.","abstract_html":"The performance of a flashing flow nozzle was quantified by efficiency and metastability measurements. Efficiency was calculated over a range of operating conditions, by using both inlet and exit conditions and the nozzle thrust. Metastability was quantified by a parameter that compared the experimental mass flow rate with homogeneous equilibrium and frozen state flow rates. The efficiency of the flashing flow nozzle was found to be less than half the efficiency of the nozzle while operating at near thermodynamic equilibrium. Attempts were made to improve nozzle performance by lowering the piping diameter immediately upstream of the nozzle to increase flow turbulence and encourage a uniform bubbly flow. Bubbly flow helps two-phase flows become less metastable, by generating a uniform distribution of bubbles that act as nucleation sites for flashing inception. Low flow metastabilities were found with high inlet qualities and small upstream piping diameters. These conditions also resulted in the highest flashing flow nozzle efficiencies; however, the efficiency showed a much less pronounced response to upstream piping diameter. The homogeneous equilibrium model was found to be an inaccurate predictor of nozzle performance. To satisfy this model, a shock must be positioned in the nozzle&#x27;s divergent section, severely limiting nozzle efficiency. The effects of phase slip on nozzle efficiency were investigated with recommendations made for further research in this area.","abstract_has_math":false,"creators":["Bunch, Thomas K."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Kornhauser, Alan A."],"committee_members":["Pierce, Felix J.","Dancey, Clinton L."],"year":1996,"date_issued":"1996-02-05","date_published":"1996-02-05","updated_at":"2026-11-18T20:17:43Z","subjects":["refrigeration","two-phase"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03042009-041255"],"render_values":[{"text":"etd-03042009-041255","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03042009-041255/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-03042009-041255/","href":"http://scholar.lib.vt.edu/theses/available/etd-03042009-041255/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/41428","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/41428","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F41428","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Kornhauser, Alan A."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Pierce, Felix J.","Dancey, Clinton L."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Bunch, Thomas K."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-03-04"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:30:59Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:30:59Z","2009-03-04"]},{"key":"dc:date.issued","label":"Date","values":["1996-02-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-03-04"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1996.B863.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 34609497"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["refrigeration","two-phase"]},{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1996.B863"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03042009-041255"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03042009-041255/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41428"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The performance of a flashing flow nozzle was quantified by efficiency and metastability measurements. Efficiency was calculated over a range of operating conditions, by using both inlet and exit conditions and the nozzle thrust. Metastability was quantified by a parameter that compared the experimental mass flow rate with homogeneous equilibrium and frozen state flow rates. The efficiency of the flashing flow nozzle was found to be less than half the efficiency of the nozzle while operating at near thermodynamic equilibrium. Attempts were made to improve nozzle performance by lowering the piping diameter immediately upstream of the nozzle to increase flow turbulence and encourage a uniform bubbly flow. Bubbly flow helps two-phase flows become less metastable, by generating a uniform distribution of bubbles that act as nucleation sites for flashing inception. Low flow metastabilities were found with high inlet qualities and small upstream piping diameters. These conditions also resulted in the highest flashing flow nozzle efficiencies; however, the efficiency showed a much less pronounced response to upstream piping diameter. The homogeneous equilibrium model was found to be an inaccurate predictor of nozzle performance. To satisfy this model, a shock must be positioned in the nozzle's divergent section, severely limiting nozzle efficiency. The effects of phase slip on nozzle efficiency were investigated with recommendations made for further research in this area."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xi, 147 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Performance measurements of a flashing flow nozzle"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Kornhauser, Alan A."],"dc:contributor.committeemember":["Pierce, Felix J.","Dancey, Clinton L."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Bunch, Thomas K."],"dc:date.accepted":["2009-03-04"],"dc:date.accessioned":["2014-03-14T21:30:59Z"],"dc:date.available":["2014-03-14T21:30:59Z","2009-03-04"],"dc:date.issued":["1996-02-05"],"dc:date.submitted":["2009-03-04"],"dc:description.abstract":["The performance of a flashing flow nozzle was quantified by efficiency and metastability measurements. Efficiency was calculated over a range of operating conditions, by using both inlet and exit conditions and the nozzle thrust. Metastability was quantified by a parameter that compared the experimental mass flow rate with homogeneous equilibrium and frozen state flow rates. The efficiency of the flashing flow nozzle was found to be less than half the efficiency of the nozzle while operating at near thermodynamic equilibrium. Attempts were made to improve nozzle performance by lowering the piping diameter immediately upstream of the nozzle to increase flow turbulence and encourage a uniform bubbly flow. Bubbly flow helps two-phase flows become less metastable, by generating a uniform distribution of bubbles that act as nucleation sites for flashing inception. Low flow metastabilities were found with high inlet qualities and small upstream piping diameters. These conditions also resulted in the highest flashing flow nozzle efficiencies; however, the efficiency showed a much less pronounced response to upstream piping diameter. The homogeneous equilibrium model was found to be an inaccurate predictor of nozzle performance. To satisfy this model, a shock must be positioned in the nozzle's divergent section, severely limiting nozzle efficiency. The effects of phase slip on nozzle efficiency were investigated with recommendations made for further research in this area."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xi, 147 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03042009-041255"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-03042009-041255/"],"dc:identifier.uri":["http://hdl.handle.net/10919/41428"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1996.B863.pdf"],"dc:relation.isformatof":["OCLC# 34609497"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["refrigeration","two-phase"],"dc:subject.lcc":["LD5655.V855 1996.B863"],"dc:title":["Performance measurements of a flashing flow nozzle"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:17:43Z"}