{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41518"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41518","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Evaluation of thermographic techniques for the detection of subsurface delaminations in concrete bridge substructures","abstract":"This thesis presents both an analytical and an experimental evaluation of the feasibility of using infrared thermographic techniques to detect subsurface damage in concrete. Various methods of artificial heating, required to effectively apply this technique, are presented. Four major conclusions are reached in this study. 1) Normal ambient diurnal atmospheric temperature changes are not generally sufficient to produce a measurable response in bridge substructures. 2) Heating by an infrared heat source is a technically viable artificial method provided some type of surface preparation is made to assure uniform emissivity. 3) Hot air heating is a viable technical alternative which does not require surface preparation prior to the application of heat. However, this method does require some type of enclosure to produce a hot air pocket. 4) Artificial heating methods based on heating blankets are not a feasible method due to local nonuniform heating effects.","abstract_html":"This thesis presents both an analytical and an experimental evaluation of the feasibility of using infrared thermographic techniques to detect subsurface damage in concrete. Various methods of artificial heating, required to effectively apply this technique, are presented. Four major conclusions are reached in this study. 1) Normal ambient diurnal atmospheric temperature changes are not generally sufficient to produce a measurable response in bridge substructures. 2) Heating by an infrared heat source is a technically viable artificial method provided some type of surface preparation is made to assure uniform emissivity. 3) Hot air heating is a viable technical alternative which does not require surface preparation prior to the application of heat. However, this method does require some type of enclosure to produce a hot air pocket. 4) Artificial heating methods based on heating blankets are not a feasible method due to local nonuniform heating effects.","abstract_has_math":false,"creators":["Warfield, Steven C."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Engineering Mechanics","degree_department":"Engineering Mechanics","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-11-18T20:16:46Z","subjects":["Concrete bridges","Corrosion and anti-corrosives"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03122009-041447"],"render_values":[{"text":"etd-03122009-041447","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03122009-041447/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-03122009-041447/","href":"http://scholar.lib.vt.edu/theses/available/etd-03122009-041447/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/41518","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/41518","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F41518","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Engineering Mechanics"]},{"key":"dc:creator","label":"Author","values":["Warfield, Steven C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-03-12"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:31:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:31:26Z","2009-03-12"]},{"key":"dc:date.issued","label":"Date","values":["1991"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-03-12"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1991.W3735.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 25404298"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Engineering Mechanics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1991.W3735"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Concrete bridges","Corrosion and anti-corrosives"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03122009-041447"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03122009-041447/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41518"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis presents both an analytical and an experimental evaluation of the feasibility of using infrared thermographic techniques to detect subsurface damage in concrete. Various methods of artificial heating, required to effectively apply this technique, are presented. Four major conclusions are reached in this study. 1) Normal ambient diurnal atmospheric temperature changes are not generally sufficient to produce a measurable response in bridge substructures. 2) Heating by an infrared heat source is a technically viable artificial method provided some type of surface preparation is made to assure uniform emissivity. 3) Hot air heating is a viable technical alternative which does not require surface preparation prior to the application of heat. However, this method does require some type of enclosure to produce a hot air pocket. 4) Artificial heating methods based on heating blankets are not a feasible method due to local nonuniform heating effects."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["170 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluation of thermographic techniques for the detection of subsurface delaminations in concrete bridge substructures"]}]}],"canonical_facts":{"dc:contributor.department":["Engineering Mechanics"],"dc:creator":["Warfield, Steven C."],"dc:date.accepted":["2009-03-12"],"dc:date.accessioned":["2014-03-14T21:31:26Z"],"dc:date.available":["2014-03-14T21:31:26Z","2009-03-12"],"dc:date.issued":["1991"],"dc:date.submitted":["2009-03-12"],"dc:description.abstract":["This thesis presents both an analytical and an experimental evaluation of the feasibility of using infrared thermographic techniques to detect subsurface damage in concrete. Various methods of artificial heating, required to effectively apply this technique, are presented. Four major conclusions are reached in this study. 1) Normal ambient diurnal atmospheric temperature changes are not generally sufficient to produce a measurable response in bridge substructures. 2) Heating by an infrared heat source is a technically viable artificial method provided some type of surface preparation is made to assure uniform emissivity. 3) Hot air heating is a viable technical alternative which does not require surface preparation prior to the application of heat. However, this method does require some type of enclosure to produce a hot air pocket. 4) Artificial heating methods based on heating blankets are not a feasible method due to local nonuniform heating effects."],"dc:description.degree":["Master of Science"],"dc:format.extent":["170 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03122009-041447"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-03122009-041447/"],"dc:identifier.uri":["http://hdl.handle.net/10919/41518"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1991.W3735.pdf"],"dc:relation.isformatof":["OCLC# 25404298"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1991.W3735"],"dc:subject.lcsh":["Concrete bridges","Corrosion and anti-corrosives"],"dc:title":["Evaluation of thermographic techniques for the detection of subsurface delaminations in concrete bridge substructures"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Engineering Mechanics"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:16:46Z"}