{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41712"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41712","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Base test method for gravity loaded standing seam roof systems","abstract":"The base test method provides a means of determining the load-carrying capacity of multiple spans, multiple purlin line standing seam roof systems. The method uses results from a single span, simply supported, two purlin line experimental tests, the 1986 American Iron and Steel Institute Specifications, and stiffness analysis of the actual design system. Currently, a base test must be conducted for each combination of purlins, deck panels, and clips that a manufacturer uses. The objective of this thesis is to investigate the possibility of eliminating the size of purlins, the orientation of purlins, length of span, and the presence or absence of insulation from a manufacturer’s required base test matrix. The findings of the investigation are based on the results of four different series of gravity load base tests. It was found that a linear relationship exists between the percentage of through-fastened capacity obtained by the purlins and their effective section moduli. This relationship was found to exist regardless of the purlin type.","abstract_html":"The base test method provides a means of determining the load-carrying capacity of multiple spans, multiple purlin line standing seam roof systems. The method uses results from a single span, simply supported, two purlin line experimental tests, the 1986 American Iron and Steel Institute Specifications, and stiffness analysis of the actual design system. Currently, a base test must be conducted for each combination of purlins, deck panels, and clips that a manufacturer uses. The objective of this thesis is to investigate the possibility of eliminating the size of purlins, the orientation of purlins, length of span, and the presence or absence of insulation from a manufacturer’s required base test matrix. The findings of the investigation are based on the results of four different series of gravity load base tests. It was found that a linear relationship exists between the percentage of through-fastened capacity obtained by the purlins and their effective section moduli. This relationship was found to exist regardless of the purlin type.","abstract_has_math":false,"creators":["Rayburn, Brian Lee"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1991,"date_issued":"1991","date_published":"1991","updated_at":"2026-11-18T20:03:10Z","subjects":["Roofing","Roofs"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03172010-020611"],"render_values":[{"text":"etd-03172010-020611","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03172010-020611/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-03172010-020611/","href":"http://scholar.lib.vt.edu/theses/available/etd-03172010-020611/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/41712","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/41712","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F41712","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Rayburn, Brian Lee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2010-03-17"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:32:04Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:32:04Z","2010-03-17"]},{"key":"dc:date.issued","label":"Date","values":["1991"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2010-03-17"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1991.R392.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 23810489"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1991.R392"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Roofing","Roofs"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03172010-020611"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03172010-020611/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41712"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The base test method provides a means of determining the load-carrying capacity of multiple spans, multiple purlin line standing seam roof systems. The method uses results from a single span, simply supported, two purlin line experimental tests, the 1986 American Iron and Steel Institute Specifications, and stiffness analysis of the actual design system. Currently, a base test must be conducted for each combination of purlins, deck panels, and clips that a manufacturer uses. The objective of this thesis is to investigate the possibility of eliminating the size of purlins, the orientation of purlins, length of span, and the presence or absence of insulation from a manufacturer’s required base test matrix. The findings of the investigation are based on the results of four different series of gravity load base tests. It was found that a linear relationship exists between the percentage of through-fastened capacity obtained by the purlins and their effective section moduli. This relationship was found to exist regardless of the purlin type."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["viii, 140 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Base test method for gravity loaded standing seam roof systems"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Rayburn, Brian Lee"],"dc:date.accepted":["2010-03-17"],"dc:date.accessioned":["2014-03-14T21:32:04Z"],"dc:date.available":["2014-03-14T21:32:04Z","2010-03-17"],"dc:date.issued":["1991"],"dc:date.submitted":["2010-03-17"],"dc:description.abstract":["The base test method provides a means of determining the load-carrying capacity of multiple spans, multiple purlin line standing seam roof systems. The method uses results from a single span, simply supported, two purlin line experimental tests, the 1986 American Iron and Steel Institute Specifications, and stiffness analysis of the actual design system. Currently, a base test must be conducted for each combination of purlins, deck panels, and clips that a manufacturer uses. The objective of this thesis is to investigate the possibility of eliminating the size of purlins, the orientation of purlins, length of span, and the presence or absence of insulation from a manufacturer’s required base test matrix. The findings of the investigation are based on the results of four different series of gravity load base tests. It was found that a linear relationship exists between the percentage of through-fastened capacity obtained by the purlins and their effective section moduli. This relationship was found to exist regardless of the purlin type."],"dc:description.degree":["Master of Science"],"dc:format.extent":["viii, 140 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03172010-020611"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-03172010-020611/"],"dc:identifier.uri":["http://hdl.handle.net/10919/41712"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1991.R392.pdf"],"dc:relation.isformatof":["OCLC# 23810489"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1991.R392"],"dc:subject.lcsh":["Roofing","Roofs"],"dc:title":["Base test method for gravity loaded standing seam roof systems"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:03:10Z"}