{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41723"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41723","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Design and testing of a sawdust dryer and a suspension sawdust burner","abstract":"The objectives of this research were to modify and test a prototype sawdust dryer designed by Arrowhead Forest Products and a sawdust-fueled suspension burner developed at Virginia Tech. The dryer was designed to process green sawdust at small to medium-sized sawmills and pallet mills. The sawdust burner was designed to be the heat source for the dryer and serve more general needs. A series of trials were conducted to develop the operating parameters of the dryer and measure the dryer's effectiveness at reducing moisture content to 0%. Separate tests were conducted on the burner to determine maximum heat outputs and combustor efficiencies using sawdust fuel of various moisture contents and particle sizes. The sawdust dryer proved capable of reducing the moisture content to 0% after several passes through the system. The sawdust burner produced close to 400,000 BTU's/HR at calculated efficiencies over 90% and proved relatively insensitive to ranges of fuel moisture contents and particle sizes.","abstract_html":"The objectives of this research were to modify and test a prototype sawdust dryer designed by Arrowhead Forest Products and a sawdust-fueled suspension burner developed at Virginia Tech. The dryer was designed to process green sawdust at small to medium-sized sawmills and pallet mills. The sawdust burner was designed to be the heat source for the dryer and serve more general needs. A series of trials were conducted to develop the operating parameters of the dryer and measure the dryer&#x27;s effectiveness at reducing moisture content to 0%. Separate tests were conducted on the burner to determine maximum heat outputs and combustor efficiencies using sawdust fuel of various moisture contents and particle sizes. The sawdust dryer proved capable of reducing the moisture content to 0% after several passes through the system. The sawdust burner produced close to 400,000 BTU&#x27;s/HR at calculated efficiencies over 90% and proved relatively insensitive to ranges of fuel moisture contents and particle sizes.","abstract_has_math":false,"creators":["Egolf, Arthur R."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Forestry","degree_department":"Forestry","school":null,"contributors":[],"advisors":[],"committee_chairs":["Stuart, William B."],"committee_members":["Mason, J. P. Jr.","Oderwald, Richard G."],"year":1992,"date_issued":"1992-05-05","date_published":"1992-05-05","updated_at":"2026-11-18T20:05:30Z","subjects":["Drying apparatus -- Testing","Wood waste as fuel","Wood waste -- Drying -- Equipment and supplies -- Testing"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03172010-020701"],"render_values":[{"text":"etd-03172010-020701","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03172010-020701/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-03172010-020701/","href":"http://scholar.lib.vt.edu/theses/available/etd-03172010-020701/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/41723","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/41723","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F41723","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Stuart, William B."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mason, J. P. Jr.","Oderwald, Richard G."]},{"key":"dc:contributor.department","label":"Department","values":["Forestry"]},{"key":"dc:creator","label":"Author","values":["Egolf, Arthur R."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2010-03-17"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:32:05Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:32:05Z","2010-03-17"]},{"key":"dc:date.issued","label":"Date","values":["1992-05-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2010-03-17"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1992.E364.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 26233788"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Forestry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1992.E364"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Drying apparatus -- Testing","Wood waste as fuel","Wood waste -- Drying -- Equipment and supplies -- Testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-03172010-020701"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-03172010-020701/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41723"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objectives of this research were to modify and test a prototype sawdust dryer designed by Arrowhead Forest Products and a sawdust-fueled suspension burner developed at Virginia Tech. The dryer was designed to process green sawdust at small to medium-sized sawmills and pallet mills. The sawdust burner was designed to be the heat source for the dryer and serve more general needs. A series of trials were conducted to develop the operating parameters of the dryer and measure the dryer's effectiveness at reducing moisture content to 0%. Separate tests were conducted on the burner to determine maximum heat outputs and combustor efficiencies using sawdust fuel of various moisture contents and particle sizes. The sawdust dryer proved capable of reducing the moisture content to 0% after several passes through the system. The sawdust burner produced close to 400,000 BTU's/HR at calculated efficiencies over 90% and proved relatively insensitive to ranges of fuel moisture contents and particle sizes."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 84 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and testing of a sawdust dryer and a suspension sawdust burner"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Stuart, William B."],"dc:contributor.committeemember":["Mason, J. P. Jr.","Oderwald, Richard G."],"dc:contributor.department":["Forestry"],"dc:creator":["Egolf, Arthur R."],"dc:date.accepted":["2010-03-17"],"dc:date.accessioned":["2014-03-14T21:32:05Z"],"dc:date.available":["2014-03-14T21:32:05Z","2010-03-17"],"dc:date.issued":["1992-05-05"],"dc:date.submitted":["2010-03-17"],"dc:description.abstract":["The objectives of this research were to modify and test a prototype sawdust dryer designed by Arrowhead Forest Products and a sawdust-fueled suspension burner developed at Virginia Tech. The dryer was designed to process green sawdust at small to medium-sized sawmills and pallet mills. The sawdust burner was designed to be the heat source for the dryer and serve more general needs. A series of trials were conducted to develop the operating parameters of the dryer and measure the dryer's effectiveness at reducing moisture content to 0%. Separate tests were conducted on the burner to determine maximum heat outputs and combustor efficiencies using sawdust fuel of various moisture contents and particle sizes. The sawdust dryer proved capable of reducing the moisture content to 0% after several passes through the system. The sawdust burner produced close to 400,000 BTU's/HR at calculated efficiencies over 90% and proved relatively insensitive to ranges of fuel moisture contents and particle sizes."],"dc:description.degree":["Master of Science"],"dc:format.extent":["ix, 84 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-03172010-020701"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-03172010-020701/"],"dc:identifier.uri":["http://hdl.handle.net/10919/41723"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1992.E364.pdf"],"dc:relation.isformatof":["OCLC# 26233788"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1992.E364"],"dc:subject.lcsh":["Drying apparatus -- Testing","Wood waste as fuel","Wood waste -- Drying -- Equipment and supplies -- Testing"],"dc:title":["Design and testing of a sawdust dryer and a suspension sawdust burner"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Forestry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:05:30Z"}