{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/41949"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/41949","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Optical analysis of the ERBE scanning thermistor bolometer radiometer using the Monte Carlo method","abstract":"In 1984, the Earth Radiation Budget Experiment (ERBE) was started by the National Aeronautics and Space Administration (NASA) to provide data to the meteorological community to predict long-term weather and climate trends. Three satellites employing nonscanning active cavity and scanning thermistor bolometer radiometers are orbiting the Earth to monitor its radiative emission. A numerical model has been formulated to better understand the performance of the ERBE scanning radiometer and to aid future radiometric design and calibration procedures. The Monte Carlo method is applied to the ERBE scanning radiometer to spectrally characterize its optical and radiative performance. The optical analysis reveals that the ERBE scanning radiometer design successfully limits the amount of energy that reaches the active sensor to the designated instrument field of view. Distribution factors between the diffuse-specular surfaces of the scanning radiometer are calculated using the Monte Carlo method and are then used to perform the radiative analysis. This analysis shows that less than three percent of the radiation emitted from the passive surfaces of the radiometer reaches the active sensor, an acceptable level for radiometric instrumentation used in space.","abstract_html":"In 1984, the Earth Radiation Budget Experiment (ERBE) was started by the National Aeronautics and Space Administration (NASA) to provide data to the meteorological community to predict long-term weather and climate trends. Three satellites employing nonscanning active cavity and scanning thermistor bolometer radiometers are orbiting the Earth to monitor its radiative emission. A numerical model has been formulated to better understand the performance of the ERBE scanning radiometer and to aid future radiometric design and calibration procedures. The Monte Carlo method is applied to the ERBE scanning radiometer to spectrally characterize its optical and radiative performance. The optical analysis reveals that the ERBE scanning radiometer design successfully limits the amount of energy that reaches the active sensor to the designated instrument field of view. Distribution factors between the diffuse-specular surfaces of the scanning radiometer are calculated using the Monte Carlo method and are then used to perform the radiative analysis. This analysis shows that less than three percent of the radiation emitted from the passive surfaces of the radiometer reaches the active sensor, an acceptable level for radiometric instrumentation used in space.","abstract_has_math":false,"creators":["Meekins, Jeffrey L."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-18T20:14:29Z","subjects":["Radiometers -- Evaluation","Terrestrial radiation -- Measurement"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04072009-040939"],"render_values":[{"text":"etd-04072009-040939","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-04072009-040939/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-04072009-040939/","href":"http://scholar.lib.vt.edu/theses/available/etd-04072009-040939/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/41949","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/41949","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F41949","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Meekins, Jeffrey L."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-04-07"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:33:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:33:02Z","2009-04-07"]},{"key":"dc:date.issued","label":"Date","values":["1990"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-04-07"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1990.M437.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 22674937"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1990.M437"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Radiometers -- Evaluation","Terrestrial radiation -- Measurement"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04072009-040939"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-04072009-040939/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/41949"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In 1984, the Earth Radiation Budget Experiment (ERBE) was started by the National Aeronautics and Space Administration (NASA) to provide data to the meteorological community to predict long-term weather and climate trends. Three satellites employing nonscanning active cavity and scanning thermistor bolometer radiometers are orbiting the Earth to monitor its radiative emission. A numerical model has been formulated to better understand the performance of the ERBE scanning radiometer and to aid future radiometric design and calibration procedures. The Monte Carlo method is applied to the ERBE scanning radiometer to spectrally characterize its optical and radiative performance. The optical analysis reveals that the ERBE scanning radiometer design successfully limits the amount of energy that reaches the active sensor to the designated instrument field of view. Distribution factors between the diffuse-specular surfaces of the scanning radiometer are calculated using the Monte Carlo method and are then used to perform the radiative analysis. This analysis shows that less than three percent of the radiation emitted from the passive surfaces of the radiometer reaches the active sensor, an acceptable level for radiometric instrumentation used in space."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiii, 193 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Optical analysis of the ERBE scanning thermistor bolometer radiometer using the Monte Carlo method"]}]}],"canonical_facts":{"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Meekins, Jeffrey L."],"dc:date.accepted":["2009-04-07"],"dc:date.accessioned":["2014-03-14T21:33:02Z"],"dc:date.available":["2014-03-14T21:33:02Z","2009-04-07"],"dc:date.issued":["1990"],"dc:date.submitted":["2009-04-07"],"dc:description.abstract":["In 1984, the Earth Radiation Budget Experiment (ERBE) was started by the National Aeronautics and Space Administration (NASA) to provide data to the meteorological community to predict long-term weather and climate trends. Three satellites employing nonscanning active cavity and scanning thermistor bolometer radiometers are orbiting the Earth to monitor its radiative emission. A numerical model has been formulated to better understand the performance of the ERBE scanning radiometer and to aid future radiometric design and calibration procedures. The Monte Carlo method is applied to the ERBE scanning radiometer to spectrally characterize its optical and radiative performance. The optical analysis reveals that the ERBE scanning radiometer design successfully limits the amount of energy that reaches the active sensor to the designated instrument field of view. Distribution factors between the diffuse-specular surfaces of the scanning radiometer are calculated using the Monte Carlo method and are then used to perform the radiative analysis. This analysis shows that less than three percent of the radiation emitted from the passive surfaces of the radiometer reaches the active sensor, an acceptable level for radiometric instrumentation used in space."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xiii, 193 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-04072009-040939"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-04072009-040939/"],"dc:identifier.uri":["http://hdl.handle.net/10919/41949"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1990.M437.pdf"],"dc:relation.isformatof":["OCLC# 22674937"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1990.M437"],"dc:subject.lcsh":["Radiometers -- Evaluation","Terrestrial radiation -- Measurement"],"dc:title":["Optical analysis of the ERBE scanning thermistor bolometer radiometer using the Monte Carlo method"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:14:29Z"}