{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/42120"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/42120","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Study of photogrammetric self-calibration adjustment method","abstract":"The development of a viable self-calibration approach for use with non-metric cameras was investigated. Both computer generated and actual test camera data were generated to determine the effectiveness of the math model and computer program. A twenty-seven parameter bundle adjustment routine was proposed because of its versatility and compatible use in an existing aerotriangulation package. For the camera and test configuration considered, the focal length was recovered to within two percent, and the principal point location was recovered to wi thin O. 3 to twelve percent. When the computer generated data was used, the focal length and principal point offset were recovered to within 0.2 percent. Modeling and software has been made available for a future comparative study between the self-calibration and Direct Linear Transformation adjustment parameters. The self-calibration modeling and former Direct Linear Transformation modeling software is a promising tool for mensuration tests and experiments with video and Charge Coupled Device (CCD) imagery.","abstract_html":"The development of a viable self-calibration approach for use with non-metric cameras was investigated. Both computer generated and actual test camera data were generated to determine the effectiveness of the math model and computer program. A twenty-seven parameter bundle adjustment routine was proposed because of its versatility and compatible use in an existing aerotriangulation package. For the camera and test configuration considered, the focal length was recovered to within two percent, and the principal point location was recovered to wi thin O. 3 to twelve percent. When the computer generated data was used, the focal length and principal point offset were recovered to within 0.2 percent. Modeling and software has been made available for a future comparative study between the self-calibration and Direct Linear Transformation adjustment parameters. The self-calibration modeling and former Direct Linear Transformation modeling software is a promising tool for mensuration tests and experiments with video and Charge Coupled Device (CCD) imagery.","abstract_has_math":false,"creators":["Long, Barrington"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Johnson, Steven D.","Bender, Lee U."],"committee_members":["Baker, James R."],"year":1990,"date_issued":"1990-05-05","date_published":"1990-05-05","updated_at":"2026-11-18T20:24:29Z","subjects":["Photogrammetry -- Calibration -- Mathematical models"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04182009-041025"],"render_values":[{"text":"etd-04182009-041025","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-04182009-041025/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-04182009-041025/","href":"http://scholar.lib.vt.edu/theses/available/etd-04182009-041025/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/42120","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/42120","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F42120","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Johnson, Steven D.","Bender, Lee U."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Baker, James R."]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Long, Barrington"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-04-18"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:34:01Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:34:01Z","2009-04-18"]},{"key":"dc:date.issued","label":"Date","values":["1990-05-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-04-18"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1990.L663.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 22437803"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1990.L663"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Photogrammetry -- Calibration -- Mathematical models"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-04182009-041025"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-04182009-041025/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/42120"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The development of a viable self-calibration approach for use with non-metric cameras was investigated. Both computer generated and actual test camera data were generated to determine the effectiveness of the math model and computer program. A twenty-seven parameter bundle adjustment routine was proposed because of its versatility and compatible use in an existing aerotriangulation package. For the camera and test configuration considered, the focal length was recovered to within two percent, and the principal point location was recovered to wi thin O. 3 to twelve percent. When the computer generated data was used, the focal length and principal point offset were recovered to within 0.2 percent. Modeling and software has been made available for a future comparative study between the self-calibration and Direct Linear Transformation adjustment parameters. The self-calibration modeling and former Direct Linear Transformation modeling software is a promising tool for mensuration tests and experiments with video and Charge Coupled Device (CCD) imagery."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 176 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Study of photogrammetric self-calibration adjustment method"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Johnson, Steven D.","Bender, Lee U."],"dc:contributor.committeemember":["Baker, James R."],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Long, Barrington"],"dc:date.accepted":["2009-04-18"],"dc:date.accessioned":["2014-03-14T21:34:01Z"],"dc:date.available":["2014-03-14T21:34:01Z","2009-04-18"],"dc:date.issued":["1990-05-05"],"dc:date.submitted":["2009-04-18"],"dc:description.abstract":["The development of a viable self-calibration approach for use with non-metric cameras was investigated. Both computer generated and actual test camera data were generated to determine the effectiveness of the math model and computer program. A twenty-seven parameter bundle adjustment routine was proposed because of its versatility and compatible use in an existing aerotriangulation package. For the camera and test configuration considered, the focal length was recovered to within two percent, and the principal point location was recovered to wi thin O. 3 to twelve percent. When the computer generated data was used, the focal length and principal point offset were recovered to within 0.2 percent. Modeling and software has been made available for a future comparative study between the self-calibration and Direct Linear Transformation adjustment parameters. The self-calibration modeling and former Direct Linear Transformation modeling software is a promising tool for mensuration tests and experiments with video and Charge Coupled Device (CCD) imagery."],"dc:description.degree":["Master of Science"],"dc:format.extent":["ix, 176 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-04182009-041025"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-04182009-041025/"],"dc:identifier.uri":["http://hdl.handle.net/10919/42120"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1990.L663.pdf"],"dc:relation.isformatof":["OCLC# 22437803"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1990.L663"],"dc:subject.lcsh":["Photogrammetry -- Calibration -- Mathematical models"],"dc:title":["Study of photogrammetric self-calibration adjustment method"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:24:29Z"}