{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/42480"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/42480","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Uplift loaded standing seam roof systems","abstract":"The objective of this thesis is to further investigate the base test method and to develop an analytical model which can accurately predict the failure of an uplift-loaded standing seam roof system. Four sets of full-scale tests were conducted and their results were analyzed along with previous results (Anderson 1991). It was found that by normalizing the data, a reduction factor could be established for each test set configuration. This reduction factor applies to both the base test and confirming multi-span test in each test set. Three analytical models were applied to predict the failure of the purlin. It was found that only the LaBoube Method accurately predicted the yield stress for only the simple span tests. It was determined that a variance exists in the failure loads of uplift-loaded standing seam roof systems which need to be investigated through testing.","abstract_html":"The objective of this thesis is to further investigate the base test method and to develop an analytical model which can accurately predict the failure of an uplift-loaded standing seam roof system. Four sets of full-scale tests were conducted and their results were analyzed along with previous results (Anderson 1991). It was found that by normalizing the data, a reduction factor could be established for each test set configuration. This reduction factor applies to both the base test and confirming multi-span test in each test set. Three analytical models were applied to predict the failure of the purlin. It was found that only the LaBoube Method accurately predicted the yield stress for only the simple span tests. It was determined that a variance exists in the failure loads of uplift-loaded standing seam roof systems which need to be investigated through testing.","abstract_has_math":false,"creators":["Pugh, Archie D."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1992,"date_issued":"1992","date_published":"1992","updated_at":"2026-11-18T20:09:00Z","subjects":["Roofs -- Design and construction"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05042010-020247"],"render_values":[{"text":"etd-05042010-020247","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-05042010-020247/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-05042010-020247/","href":"http://scholar.lib.vt.edu/theses/available/etd-05042010-020247/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/42480","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/42480","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F42480","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Pugh, Archie D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2010-05-04"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:35:33Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:35:33Z","2010-05-04"]},{"key":"dc:date.issued","label":"Date","values":["1992"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2010-05-04"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1992.P833.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 25753550"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1992.P833"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Roofs -- Design and construction"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-05042010-020247"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-05042010-020247/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/42480"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this thesis is to further investigate the base test method and to develop an analytical model which can accurately predict the failure of an uplift-loaded standing seam roof system. Four sets of full-scale tests were conducted and their results were analyzed along with previous results (Anderson 1991). It was found that by normalizing the data, a reduction factor could be established for each test set configuration. This reduction factor applies to both the base test and confirming multi-span test in each test set. Three analytical models were applied to predict the failure of the purlin. It was found that only the LaBoube Method accurately predicted the yield stress for only the simple span tests. It was determined that a variance exists in the failure loads of uplift-loaded standing seam roof systems which need to be investigated through testing."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 146 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Uplift loaded standing seam roof systems"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Pugh, Archie D."],"dc:date.accepted":["2010-05-04"],"dc:date.accessioned":["2014-03-14T21:35:33Z"],"dc:date.available":["2014-03-14T21:35:33Z","2010-05-04"],"dc:date.issued":["1992"],"dc:date.submitted":["2010-05-04"],"dc:description.abstract":["The objective of this thesis is to further investigate the base test method and to develop an analytical model which can accurately predict the failure of an uplift-loaded standing seam roof system. Four sets of full-scale tests were conducted and their results were analyzed along with previous results (Anderson 1991). It was found that by normalizing the data, a reduction factor could be established for each test set configuration. This reduction factor applies to both the base test and confirming multi-span test in each test set. Three analytical models were applied to predict the failure of the purlin. It was found that only the LaBoube Method accurately predicted the yield stress for only the simple span tests. It was determined that a variance exists in the failure loads of uplift-loaded standing seam roof systems which need to be investigated through testing."],"dc:description.degree":["Master of Science"],"dc:format.extent":["ix, 146 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-05042010-020247"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-05042010-020247/"],"dc:identifier.uri":["http://hdl.handle.net/10919/42480"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1992.P833.pdf"],"dc:relation.isformatof":["OCLC# 25753550"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1992.P833"],"dc:subject.lcsh":["Roofs -- Design and construction"],"dc:title":["Uplift loaded standing seam roof systems"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:09:00Z"}