{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/42921"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/42921","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Oxygen diffusion within arterioles and venules","abstract":"Oxygen transfer was studied within the arterioles and venules (40 to 100 μm in diameter) of a hamster cheek pouch retractor muscle. Previously obtained transluminal oxygen saturation, red blood cell velocity, and hemoglobin concentration were used for the analysis. Because of branching and transfer to the tissue, the measured oxygen profiles across the vessels were nonuniform. At each axial location, the profiles were converted to radial distributions using a convolution algorithm. The results were modeled using a numerical solution of the convective mass transport equation assuming the blood to be a homogenous mixture. Effective diffusion coefficients were found by matching the axial development of the radial oxygen distribution predicted by the analytical model with the experimental data. The resulting oxygen diffusion coefficients were an order of magnitude higher than have been measured in vitro. This appears to support other evidence relating to the higher than expected oxygen transport in the microcirculation.","abstract_html":"Oxygen transfer was studied within the arterioles and venules (40 to 100 μm in diameter) of a hamster cheek pouch retractor muscle. Previously obtained transluminal oxygen saturation, red blood cell velocity, and hemoglobin concentration were used for the analysis. Because of branching and transfer to the tissue, the measured oxygen profiles across the vessels were nonuniform. At each axial location, the profiles were converted to radial distributions using a convolution algorithm. The results were modeled using a numerical solution of the convective mass transport equation assuming the blood to be a homogenous mixture. Effective diffusion coefficients were found by matching the axial development of the radial oxygen distribution predicted by the analytical model with the experimental data. The resulting oxygen diffusion coefficients were an order of magnitude higher than have been measured in vitro. This appears to support other evidence relating to the higher than expected oxygen transport in the microcirculation.","abstract_has_math":false,"creators":["Mancuso, Thomas"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-18T20:24:36Z","subjects":["Oxygen -- Physiological transport -- Research"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06082009-171201"],"render_values":[{"text":"etd-06082009-171201","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06082009-171201/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-06082009-171201/","href":"http://scholar.lib.vt.edu/theses/available/etd-06082009-171201/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/42921","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/42921","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F42921","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Mancuso, Thomas"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-06-08"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:37:12Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:37:12Z","2009-06-08"]},{"key":"dc:date.issued","label":"Date","values":["1990"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-06-08"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1990.M364.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 22293955"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1990.M364"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Oxygen -- Physiological transport -- Research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06082009-171201"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06082009-171201/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/42921"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Oxygen transfer was studied within the arterioles and venules (40 to 100 μm in diameter) of a hamster cheek pouch retractor muscle. Previously obtained transluminal oxygen saturation, red blood cell velocity, and hemoglobin concentration were used for the analysis. Because of branching and transfer to the tissue, the measured oxygen profiles across the vessels were nonuniform. At each axial location, the profiles were converted to radial distributions using a convolution algorithm. The results were modeled using a numerical solution of the convective mass transport equation assuming the blood to be a homogenous mixture. Effective diffusion coefficients were found by matching the axial development of the radial oxygen distribution predicted by the analytical model with the experimental data. The resulting oxygen diffusion coefficients were an order of magnitude higher than have been measured in vitro. This appears to support other evidence relating to the higher than expected oxygen transport in the microcirculation."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xv, 182 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Oxygen diffusion within arterioles and venules"]}]}],"canonical_facts":{"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Mancuso, Thomas"],"dc:date.accepted":["2009-06-08"],"dc:date.accessioned":["2014-03-14T21:37:12Z"],"dc:date.available":["2014-03-14T21:37:12Z","2009-06-08"],"dc:date.issued":["1990"],"dc:date.submitted":["2009-06-08"],"dc:description.abstract":["Oxygen transfer was studied within the arterioles and venules (40 to 100 μm in diameter) of a hamster cheek pouch retractor muscle. Previously obtained transluminal oxygen saturation, red blood cell velocity, and hemoglobin concentration were used for the analysis. Because of branching and transfer to the tissue, the measured oxygen profiles across the vessels were nonuniform. At each axial location, the profiles were converted to radial distributions using a convolution algorithm. The results were modeled using a numerical solution of the convective mass transport equation assuming the blood to be a homogenous mixture. Effective diffusion coefficients were found by matching the axial development of the radial oxygen distribution predicted by the analytical model with the experimental data. The resulting oxygen diffusion coefficients were an order of magnitude higher than have been measured in vitro. This appears to support other evidence relating to the higher than expected oxygen transport in the microcirculation."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xv, 182 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06082009-171201"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-06082009-171201/"],"dc:identifier.uri":["http://hdl.handle.net/10919/42921"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1990.M364.pdf"],"dc:relation.isformatof":["OCLC# 22293955"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1990.M364"],"dc:subject.lcsh":["Oxygen -- Physiological transport -- Research"],"dc:title":["Oxygen diffusion within arterioles and venules"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:24:36Z"}