{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43036"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43036","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A comparison of oxygen utilization determination techniques for the activated sludge process","abstract":"Evaluation of the data from the series of batch experiments has led to the following conclusions: 1. Currently used methods of quantifying oxygen uptake rate, especially for batch reactors, yield values of oxygen utilization considerably lower than those predicted by mass balance considerations for these three wastes. In the face of Blok's published data indicating much better results with a short run reactor, it must be assumed that the length of run selected was at least partially responsible. 2. While quantitatively unsatisfactory, the methods for determining oxygen uptake used in these experiments seem to be of some use as monitors of biological systems. Changes in slope of the oxygen utilization curve were found to be more apparent at lower loadings.","abstract_html":"Evaluation of the data from the series of batch experiments has led to the following conclusions: 1. Currently used methods of quantifying oxygen uptake rate, especially for batch reactors, yield values of oxygen utilization considerably lower than those predicted by mass balance considerations for these three wastes. In the face of Blok&#x27;s published data indicating much better results with a short run reactor, it must be assumed that the length of run selected was at least partially responsible. 2. While quantitatively unsatisfactory, the methods for determining oxygen uptake used in these experiments seem to be of some use as monitors of biological systems. Changes in slope of the oxygen utilization curve were found to be more apparent at lower loadings.","abstract_has_math":false,"creators":["Stallard, Warren Michael"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Sanitary Engineering","degree_department":"Sanitary Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Randall, Clifford W."],"committee_members":["King, Paul H.","Sherrard, Joseph H."],"year":1976,"date_issued":"1976-09-15","date_published":"1976-09-15","updated_at":"2026-11-18T20:18:42Z","subjects":["wastes","oxygen utilization"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06102012-040141"],"render_values":[{"text":"etd-06102012-040141","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06102012-040141/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-06102012-040141/","href":"http://scholar.lib.vt.edu/theses/available/etd-06102012-040141/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/43036","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/43036","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F43036","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Randall, Clifford W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["King, Paul H.","Sherrard, Joseph H."]},{"key":"dc:contributor.department","label":"Department","values":["Sanitary Engineering"]},{"key":"dc:creator","label":"Author","values":["Stallard, Warren Michael"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2012-06-10"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:37:38Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:37:38Z","2012-06-10"]},{"key":"dc:date.issued","label":"Date","values":["1976-09-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012-06-10"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1976.S727.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 39285087"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Sanitary Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["wastes","oxygen utilization"]},{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1976.S727"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06102012-040141"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06102012-040141/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43036"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Evaluation of the data from the series of batch experiments has led to the following conclusions: 1. Currently used methods of quantifying oxygen uptake rate, especially for batch reactors, yield values of oxygen utilization considerably lower than those predicted by mass balance considerations for these three wastes. In the face of Blok's published data indicating much better results with a short run reactor, it must be assumed that the length of run selected was at least partially responsible. 2. While quantitatively unsatisfactory, the methods for determining oxygen uptake used in these experiments seem to be of some use as monitors of biological systems. Changes in slope of the oxygen utilization curve were found to be more apparent at lower loadings."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vi, 67 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A comparison of oxygen utilization determination techniques for the activated sludge process"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Randall, Clifford W."],"dc:contributor.committeemember":["King, Paul H.","Sherrard, Joseph H."],"dc:contributor.department":["Sanitary Engineering"],"dc:creator":["Stallard, Warren Michael"],"dc:date.accepted":["2012-06-10"],"dc:date.accessioned":["2014-03-14T21:37:38Z"],"dc:date.available":["2014-03-14T21:37:38Z","2012-06-10"],"dc:date.issued":["1976-09-15"],"dc:date.submitted":["2012-06-10"],"dc:description.abstract":["Evaluation of the data from the series of batch experiments has led to the following conclusions: 1. Currently used methods of quantifying oxygen uptake rate, especially for batch reactors, yield values of oxygen utilization considerably lower than those predicted by mass balance considerations for these three wastes. In the face of Blok's published data indicating much better results with a short run reactor, it must be assumed that the length of run selected was at least partially responsible. 2. While quantitatively unsatisfactory, the methods for determining oxygen uptake used in these experiments seem to be of some use as monitors of biological systems. Changes in slope of the oxygen utilization curve were found to be more apparent at lower loadings."],"dc:description.degree":["Master of Science"],"dc:format.extent":["vi, 67 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06102012-040141"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-06102012-040141/"],"dc:identifier.uri":["http://hdl.handle.net/10919/43036"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1976.S727.pdf"],"dc:relation.isformatof":["OCLC# 39285087"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["wastes","oxygen utilization"],"dc:subject.lcc":["LD5655.V855 1976.S727"],"dc:title":["A comparison of oxygen utilization determination techniques for the activated sludge process"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Sanitary Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:18:42Z"}