{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43101"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43101","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Investigation of air control on chunkwood combustor","abstract":"Many small scale agricultural operations such as greenhouses, peanut drying and tobacco curing, use significant quantities of thermal energy. Direct combustion of biomass is a potential source of heat energy for those agricultural applications to substitute for the electricity or fossil fuels (principally LP gas) currently used. However, small scale combustion equipment often operates with low efficiency and high emissions. A prototype chunkwood combustor was installed and tested. The basis for controlling heat output, was the modulation of air supplied to the primary and secondary combustors. Exhaust gas CO and CO₂ concentrations, combustor efficiency, and useful heat output were measured. The cleanest burn was achieved during a forty minute test, where 50 percent of stoichiometric air was introduced at the primary, and 170 percent at the secondary, for a total of 220 percent stoichiometric. The overall average CO/CO₂ ratio for this test was 0.084, and 0.1 is considered to be an average rating for a combustion in a wood stove. Moreover, the efficiency during this test was 52 percent.","abstract_html":"Many small scale agricultural operations such as greenhouses, peanut drying and tobacco curing, use significant quantities of thermal energy. Direct combustion of biomass is a potential source of heat energy for those agricultural applications to substitute for the electricity or fossil fuels (principally LP gas) currently used. However, small scale combustion equipment often operates with low efficiency and high emissions. A prototype chunkwood combustor was installed and tested. The basis for controlling heat output, was the modulation of air supplied to the primary and secondary combustors. Exhaust gas CO and CO₂ concentrations, combustor efficiency, and useful heat output were measured. The cleanest burn was achieved during a forty minute test, where 50 percent of stoichiometric air was introduced at the primary, and 170 percent at the secondary, for a total of 220 percent stoichiometric. The overall average CO/CO₂ ratio for this test was 0.084, and 0.1 is considered to be an average rating for a combustion in a wood stove. Moreover, the efficiency during this test was 52 percent.","abstract_has_math":false,"creators":["Moscahlaidis, George"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Agricultural Engineering","degree_department":"Agricultural Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Cundiff, John S."],"committee_members":["Mason, J. P.","Jaasma, Dennis R."],"year":1989,"date_issued":"1989-03-05","date_published":"1989-03-05","updated_at":"2026-11-18T20:15:28Z","subjects":["Combustion -- Research"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06102012-040555"],"render_values":[{"text":"etd-06102012-040555","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06102012-040555/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-06102012-040555/","href":"http://scholar.lib.vt.edu/theses/available/etd-06102012-040555/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/43101","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/43101","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F43101","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Cundiff, John S."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mason, J. P.","Jaasma, Dennis R."]},{"key":"dc:contributor.department","label":"Department","values":["Agricultural Engineering"]},{"key":"dc:creator","label":"Author","values":["Moscahlaidis, George"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2012-06-10"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:37:47Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:37:47Z","2012-06-10"]},{"key":"dc:date.issued","label":"Date","values":["1989-03-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012-06-10"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1989.M682.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 19831042"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Agricultural Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1989.M682"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Combustion -- Research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06102012-040555"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06102012-040555/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43101"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Many small scale agricultural operations such as greenhouses, peanut drying and tobacco curing, use significant quantities of thermal energy. Direct combustion of biomass is a potential source of heat energy for those agricultural applications to substitute for the electricity or fossil fuels (principally LP gas) currently used. However, small scale combustion equipment often operates with low efficiency and high emissions. A prototype chunkwood combustor was installed and tested. The basis for controlling heat output, was the modulation of air supplied to the primary and secondary combustors. Exhaust gas CO and CO₂ concentrations, combustor efficiency, and useful heat output were measured. The cleanest burn was achieved during a forty minute test, where 50 percent of stoichiometric air was introduced at the primary, and 170 percent at the secondary, for a total of 220 percent stoichiometric. The overall average CO/CO₂ ratio for this test was 0.084, and 0.1 is considered to be an average rating for a combustion in a wood stove. Moreover, the efficiency during this test was 52 percent."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 120 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Investigation of air control on chunkwood combustor"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Cundiff, John S."],"dc:contributor.committeemember":["Mason, J. P.","Jaasma, Dennis R."],"dc:contributor.department":["Agricultural Engineering"],"dc:creator":["Moscahlaidis, George"],"dc:date.accepted":["2012-06-10"],"dc:date.accessioned":["2014-03-14T21:37:47Z"],"dc:date.available":["2014-03-14T21:37:47Z","2012-06-10"],"dc:date.issued":["1989-03-05"],"dc:date.submitted":["2012-06-10"],"dc:description.abstract":["Many small scale agricultural operations such as greenhouses, peanut drying and tobacco curing, use significant quantities of thermal energy. Direct combustion of biomass is a potential source of heat energy for those agricultural applications to substitute for the electricity or fossil fuels (principally LP gas) currently used. However, small scale combustion equipment often operates with low efficiency and high emissions. A prototype chunkwood combustor was installed and tested. The basis for controlling heat output, was the modulation of air supplied to the primary and secondary combustors. Exhaust gas CO and CO₂ concentrations, combustor efficiency, and useful heat output were measured. The cleanest burn was achieved during a forty minute test, where 50 percent of stoichiometric air was introduced at the primary, and 170 percent at the secondary, for a total of 220 percent stoichiometric. The overall average CO/CO₂ ratio for this test was 0.084, and 0.1 is considered to be an average rating for a combustion in a wood stove. Moreover, the efficiency during this test was 52 percent."],"dc:description.degree":["Master of Science"],"dc:format.extent":["ix, 120 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06102012-040555"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-06102012-040555/"],"dc:identifier.uri":["http://hdl.handle.net/10919/43101"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1989.M682.pdf"],"dc:relation.isformatof":["OCLC# 19831042"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1989.M682"],"dc:subject.lcsh":["Combustion -- Research"],"dc:title":["Investigation of air control on chunkwood combustor"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Agricultural Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:15:28Z"}