{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43148"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43148","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Evaluation of GFRP framing connections","abstract":"The objective of this thesis is to verify the assumption of designing the connection as simply supported in a GFRP bonded-bolted framing angle configuration. To achieve this, nine framing angle connection tests were performed. The assumption was found to be valid for the 2 bolt bonded, the 2 bolt unbonded, and the 3 bolt unbonded framing angle connections tested, however, more tests are needed varying different parameters before final conclusions can be reached. Suggestions are made for different areas of possible research into GFRP.","abstract_html":"The objective of this thesis is to verify the assumption of designing the connection as simply supported in a GFRP bonded-bolted framing angle configuration. To achieve this, nine framing angle connection tests were performed. The assumption was found to be valid for the 2 bolt bonded, the 2 bolt unbonded, and the 3 bolt unbonded framing angle connections tested, however, more tests are needed varying different parameters before final conclusions can be reached. Suggestions are made for different areas of possible research into GFRP.","abstract_has_math":false,"creators":["Larson, Karl W."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-18T20:21:42Z","subjects":["Glass-reinforced plastics -- Testing"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063336"],"render_values":[{"text":"etd-06112009-063336","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06112009-063336/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-06112009-063336/","href":"http://scholar.lib.vt.edu/theses/available/etd-06112009-063336/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/43148","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/43148","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F43148","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Larson, Karl W."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-06-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:37:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:37:55Z","2009-06-11"]},{"key":"dc:date.issued","label":"Date","values":["1994"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-06-11"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1994.L377.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 31053863"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1994.L377"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Glass-reinforced plastics -- Testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063336"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06112009-063336/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43148"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this thesis is to verify the assumption of designing the connection as simply supported in a GFRP bonded-bolted framing angle configuration. To achieve this, nine framing angle connection tests were performed. The assumption was found to be valid for the 2 bolt bonded, the 2 bolt unbonded, and the 3 bolt unbonded framing angle connections tested, however, more tests are needed varying different parameters before final conclusions can be reached. Suggestions are made for different areas of possible research into GFRP."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xi, 161 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluation of GFRP framing connections"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Larson, Karl W."],"dc:date.accepted":["2009-06-11"],"dc:date.accessioned":["2014-03-14T21:37:55Z"],"dc:date.available":["2014-03-14T21:37:55Z","2009-06-11"],"dc:date.issued":["1994"],"dc:date.submitted":["2009-06-11"],"dc:description.abstract":["The objective of this thesis is to verify the assumption of designing the connection as simply supported in a GFRP bonded-bolted framing angle configuration. To achieve this, nine framing angle connection tests were performed. The assumption was found to be valid for the 2 bolt bonded, the 2 bolt unbonded, and the 3 bolt unbonded framing angle connections tested, however, more tests are needed varying different parameters before final conclusions can be reached. Suggestions are made for different areas of possible research into GFRP."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xi, 161 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06112009-063336"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-06112009-063336/"],"dc:identifier.uri":["http://hdl.handle.net/10919/43148"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1994.L377.pdf"],"dc:relation.isformatof":["OCLC# 31053863"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1994.L377"],"dc:subject.lcsh":["Glass-reinforced plastics -- Testing"],"dc:title":["Evaluation of GFRP framing connections"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:21:42Z"}