{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43193"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43193","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Utilization of a combined activated sludge fixed film media system for treatment of a high strength, high ammonia, industrial wastewater","abstract":"Combined activated sludge-fixed film media treatment systems are an interesting innovation in treatment technology. By adding media into the aeration basin, increased biomass concentrations may be maintained with little or no increase in solids loading to the clarifier. The ideal combined system can treat higher organic and ammonia loadings than a conventional system, and is more resistant to temperature changes and shock loadings. Overloaded plants can be outfitted with media as an alternative to plant expansion, and initial designs of combined systems can result in smaller aeration basins and clarifiers in places of land scarcity.","abstract_html":"Combined activated sludge-fixed film media treatment systems are an interesting innovation in treatment technology. By adding media into the aeration basin, increased biomass concentrations may be maintained with little or no increase in solids loading to the clarifier. The ideal combined system can treat higher organic and ammonia loadings than a conventional system, and is more resistant to temperature changes and shock loadings. Overloaded plants can be outfitted with media as an alternative to plant expansion, and initial designs of combined systems can result in smaller aeration basins and clarifiers in places of land scarcity.","abstract_has_math":false,"creators":["Louis, Richard Joseph"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Environmental Planning","degree_department":"Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Randall, Clifford W."],"committee_members":["Knocke, William R.","Novak, John T."],"year":1993,"date_issued":"1993-05-05","date_published":"1993-05-05","updated_at":"2026-11-18T20:24:45Z","subjects":["Factory and trade waste -- Environmental aspects","Sewage -- Purification -- Activated sludge process"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063901"],"render_values":[{"text":"etd-06112009-063901","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06112009-063901/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-06112009-063901/","href":"http://scholar.lib.vt.edu/theses/available/etd-06112009-063901/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/43193","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/43193","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F43193","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Randall, Clifford W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Knocke, William R.","Novak, John T."]},{"key":"dc:contributor.department","label":"Department","values":["Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Louis, Richard Joseph"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-06-11"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:38:07Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:38:07Z","2009-06-11"]},{"key":"dc:date.issued","label":"Date","values":["1993-05-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-06-11"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1993.L684.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 29741659"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Planning"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1993.L684"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Factory and trade waste -- Environmental aspects","Sewage -- Purification -- Activated sludge process"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-06112009-063901"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-06112009-063901/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43193"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Combined activated sludge-fixed film media treatment systems are an interesting innovation in treatment technology. By adding media into the aeration basin, increased biomass concentrations may be maintained with little or no increase in solids loading to the clarifier. The ideal combined system can treat higher organic and ammonia loadings than a conventional system, and is more resistant to temperature changes and shock loadings. Overloaded plants can be outfitted with media as an alternative to plant expansion, and initial designs of combined systems can result in smaller aeration basins and clarifiers in places of land scarcity."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xi, 143 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Utilization of a combined activated sludge fixed film media system for treatment of a high strength, high ammonia, industrial wastewater"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Randall, Clifford W."],"dc:contributor.committeemember":["Knocke, William R.","Novak, John T."],"dc:contributor.department":["Environmental Engineering"],"dc:creator":["Louis, Richard Joseph"],"dc:date.accepted":["2009-06-11"],"dc:date.accessioned":["2014-03-14T21:38:07Z"],"dc:date.available":["2014-03-14T21:38:07Z","2009-06-11"],"dc:date.issued":["1993-05-05"],"dc:date.submitted":["2009-06-11"],"dc:description.abstract":["Combined activated sludge-fixed film media treatment systems are an interesting innovation in treatment technology. By adding media into the aeration basin, increased biomass concentrations may be maintained with little or no increase in solids loading to the clarifier. The ideal combined system can treat higher organic and ammonia loadings than a conventional system, and is more resistant to temperature changes and shock loadings. Overloaded plants can be outfitted with media as an alternative to plant expansion, and initial designs of combined systems can result in smaller aeration basins and clarifiers in places of land scarcity."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xi, 143 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-06112009-063901"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-06112009-063901/"],"dc:identifier.uri":["http://hdl.handle.net/10919/43193"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1993.L684.pdf"],"dc:relation.isformatof":["OCLC# 29741659"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1993.L684"],"dc:subject.lcsh":["Factory and trade waste -- Environmental aspects","Sewage -- Purification -- Activated sludge process"],"dc:title":["Utilization of a combined activated sludge fixed film media system for treatment of a high strength, high ammonia, industrial wastewater"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Environmental Planning"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:24:45Z"}