{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43620"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43620","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Behavior of composite semi-rigid beam-to-girder connections","abstract":"Advancements in design technology and construction materials have allowed composite floor systems to become longer and shallower. As a result, serviceability considerations rather than strength considerations have started to control designs. Partial continuity in composite floor systems has been suggested as a means by which the serviceability aspects could be improved. A new beam-to-girder connection referred to as a composite semi-rigid beam-to-girder connection is investigated as a possible method to provide partial continuity in floor systems. Four of these connections are evaluated experimentally and analytically to determine their behavior and the feasibility of their use in typical composite floor systems. The results indicate that these connections would improve serviceability aspects of the floor system and would improve the general efficiency of the floor design.","abstract_html":"Advancements in design technology and construction materials have allowed composite floor systems to become longer and shallower. As a result, serviceability considerations rather than strength considerations have started to control designs. Partial continuity in composite floor systems has been suggested as a means by which the serviceability aspects could be improved. A new beam-to-girder connection referred to as a composite semi-rigid beam-to-girder connection is investigated as a possible method to provide partial continuity in floor systems. Four of these connections are evaluated experimentally and analytically to determine their behavior and the feasibility of their use in typical composite floor systems. The results indicate that these connections would improve serviceability aspects of the floor system and would improve the general efficiency of the floor design.","abstract_has_math":false,"creators":["Rex, Clinton O."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1994,"date_issued":"1994","date_published":"1994","updated_at":"2026-11-18T19:58:55Z","subjects":["Composite construction","Floors","Girders"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07102009-040338"],"render_values":[{"text":"etd-07102009-040338","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-07102009-040338/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-07102009-040338/","href":"http://scholar.lib.vt.edu/theses/available/etd-07102009-040338/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/43620","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/43620","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F43620","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Rex, Clinton O."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-07-10"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:39:55Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:39:55Z","2009-07-10"]},{"key":"dc:date.issued","label":"Date","values":["1994"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-07-10"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1994.R49.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 30505543"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1994.R49"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Composite construction","Floors","Girders"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07102009-040338"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-07102009-040338/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43620"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Advancements in design technology and construction materials have allowed composite floor systems to become longer and shallower. As a result, serviceability considerations rather than strength considerations have started to control designs. Partial continuity in composite floor systems has been suggested as a means by which the serviceability aspects could be improved. A new beam-to-girder connection referred to as a composite semi-rigid beam-to-girder connection is investigated as a possible method to provide partial continuity in floor systems. Four of these connections are evaluated experimentally and analytically to determine their behavior and the feasibility of their use in typical composite floor systems. The results indicate that these connections would improve serviceability aspects of the floor system and would improve the general efficiency of the floor design."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiii, 295 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Behavior of composite semi-rigid beam-to-girder connections"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Rex, Clinton O."],"dc:date.accepted":["2009-07-10"],"dc:date.accessioned":["2014-03-14T21:39:55Z"],"dc:date.available":["2014-03-14T21:39:55Z","2009-07-10"],"dc:date.issued":["1994"],"dc:date.submitted":["2009-07-10"],"dc:description.abstract":["Advancements in design technology and construction materials have allowed composite floor systems to become longer and shallower. As a result, serviceability considerations rather than strength considerations have started to control designs. Partial continuity in composite floor systems has been suggested as a means by which the serviceability aspects could be improved. A new beam-to-girder connection referred to as a composite semi-rigid beam-to-girder connection is investigated as a possible method to provide partial continuity in floor systems. Four of these connections are evaluated experimentally and analytically to determine their behavior and the feasibility of their use in typical composite floor systems. The results indicate that these connections would improve serviceability aspects of the floor system and would improve the general efficiency of the floor design."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xiii, 295 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-07102009-040338"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-07102009-040338/"],"dc:identifier.uri":["http://hdl.handle.net/10919/43620"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1994.R49.pdf"],"dc:relation.isformatof":["OCLC# 30505543"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1994.R49"],"dc:subject.lcsh":["Composite construction","Floors","Girders"],"dc:title":["Behavior of composite semi-rigid beam-to-girder connections"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T19:58:55Z"}