{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/43720"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/43720","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Design and calibration of a high temperature continuous run electric arc wind tunnel","abstract":"The purpose of this thesis project was to design, construct and evaluate the performance of a high temperature continuous-run electric arc wind tunnel. A pilot model of such a facility was designed assuming that equilibrium air was the working gas. The pilot model facility was constructed and consisted of the following components; arc chamber, stagnation chamber, nozzle section, test and diffusor sections. In the arc chamber, the air passes through the positive column of an electric arc there-by raising its stagnation temperature before entering the stagnation chamber. Also included in the design and construction were water cooling and waste disposal systems, air supply and vacuum systems, and electric arc power supply system and control. An examination of tests performed in the electric-arc facility showed that a low density supersonic flow with a stagnation temperature of approximately 10,000 F could be produced. The power level for this flow was 36 kw; however, with an expected increase of power to 72 kw the stagnation temperature should be raised to 15,000 F. Since no valid technique for measuring temperatures of this magnitude has been perfected to the author's knowledge, these temperatures were calculated according to a method as outlined in the present thesis. The present facility will present an opportunity for study in such topic areas as (1) Aerodynamic Ablation, (2) Magnetoaerodynamic studies and (3) Qualitative studies of chemically reacting gas flows.","abstract_html":"The purpose of this thesis project was to design, construct and evaluate the performance of a high temperature continuous-run electric arc wind tunnel. A pilot model of such a facility was designed assuming that equilibrium air was the working gas. The pilot model facility was constructed and consisted of the following components; arc chamber, stagnation chamber, nozzle section, test and diffusor sections. In the arc chamber, the air passes through the positive column of an electric arc there-by raising its stagnation temperature before entering the stagnation chamber. Also included in the design and construction were water cooling and waste disposal systems, air supply and vacuum systems, and electric arc power supply system and control. An examination of tests performed in the electric-arc facility showed that a low density supersonic flow with a stagnation temperature of approximately 10,000 F could be produced. The power level for this flow was 36 kw; however, with an expected increase of power to 72 kw the stagnation temperature should be raised to 15,000 F. Since no valid technique for measuring temperatures of this magnitude has been perfected to the author&#x27;s knowledge, these temperatures were calculated according to a method as outlined in the present thesis. The present facility will present an opportunity for study in such topic areas as (1) Aerodynamic Ablation, (2) Magnetoaerodynamic studies and (3) Qualitative studies of chemically reacting gas flows.","abstract_has_math":false,"creators":["Grossmann, William"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Aeronautical Engineering","degree_department":"Aeronautical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Truitt, Robert W."],"committee_members":["Bruce, Arthur C."],"year":1961,"date_issued":"1961-04-15","date_published":"1961-04-15","updated_at":"2026-11-18T20:10:06Z","subjects":["Wind tunnels -- Calibration"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07152010-020018"],"render_values":[{"text":"etd-07152010-020018","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-07152010-020018/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-07152010-020018/","href":"http://scholar.lib.vt.edu/theses/available/etd-07152010-020018/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/43720","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/43720","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F43720","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Truitt, Robert W."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Bruce, Arthur C."]},{"key":"dc:contributor.department","label":"Department","values":["Aeronautical Engineering"]},{"key":"dc:creator","label":"Author","values":["Grossmann, William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2010-07-15"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:40:26Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:40:26Z","2010-07-15"]},{"key":"dc:date.issued","label":"Date","values":["1961-04-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2010-07-15"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1961.G767.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 26923092"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Aeronautical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1961.G767"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Wind tunnels -- Calibration"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-07152010-020018"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-07152010-020018/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/43720"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The purpose of this thesis project was to design, construct and evaluate the performance of a high temperature continuous-run electric arc wind tunnel. A pilot model of such a facility was designed assuming that equilibrium air was the working gas. The pilot model facility was constructed and consisted of the following components; arc chamber, stagnation chamber, nozzle section, test and diffusor sections. In the arc chamber, the air passes through the positive column of an electric arc there-by raising its stagnation temperature before entering the stagnation chamber. Also included in the design and construction were water cooling and waste disposal systems, air supply and vacuum systems, and electric arc power supply system and control. An examination of tests performed in the electric-arc facility showed that a low density supersonic flow with a stagnation temperature of approximately 10,000 F could be produced. The power level for this flow was 36 kw; however, with an expected increase of power to 72 kw the stagnation temperature should be raised to 15,000 F. Since no valid technique for measuring temperatures of this magnitude has been perfected to the author's knowledge, these temperatures were calculated according to a method as outlined in the present thesis. The present facility will present an opportunity for study in such topic areas as (1) Aerodynamic Ablation, (2) Magnetoaerodynamic studies and (3) Qualitative studies of chemically reacting gas flows."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["66 pages, 2 unnumbered leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Design and calibration of a high temperature continuous run electric arc wind tunnel"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Truitt, Robert W."],"dc:contributor.committeemember":["Bruce, Arthur C."],"dc:contributor.department":["Aeronautical Engineering"],"dc:creator":["Grossmann, William"],"dc:date.accepted":["2010-07-15"],"dc:date.accessioned":["2014-03-14T21:40:26Z"],"dc:date.available":["2014-03-14T21:40:26Z","2010-07-15"],"dc:date.issued":["1961-04-15"],"dc:date.submitted":["2010-07-15"],"dc:description.abstract":["The purpose of this thesis project was to design, construct and evaluate the performance of a high temperature continuous-run electric arc wind tunnel. A pilot model of such a facility was designed assuming that equilibrium air was the working gas. The pilot model facility was constructed and consisted of the following components; arc chamber, stagnation chamber, nozzle section, test and diffusor sections. In the arc chamber, the air passes through the positive column of an electric arc there-by raising its stagnation temperature before entering the stagnation chamber. Also included in the design and construction were water cooling and waste disposal systems, air supply and vacuum systems, and electric arc power supply system and control. An examination of tests performed in the electric-arc facility showed that a low density supersonic flow with a stagnation temperature of approximately 10,000 F could be produced. The power level for this flow was 36 kw; however, with an expected increase of power to 72 kw the stagnation temperature should be raised to 15,000 F. Since no valid technique for measuring temperatures of this magnitude has been perfected to the author's knowledge, these temperatures were calculated according to a method as outlined in the present thesis. The present facility will present an opportunity for study in such topic areas as (1) Aerodynamic Ablation, (2) Magnetoaerodynamic studies and (3) Qualitative studies of chemically reacting gas flows."],"dc:description.degree":["Master of Science"],"dc:format.extent":["66 pages, 2 unnumbered leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-07152010-020018"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-07152010-020018/"],"dc:identifier.uri":["http://hdl.handle.net/10919/43720"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1961.G767.pdf"],"dc:relation.isformatof":["OCLC# 26923092"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1961.G767"],"dc:subject.lcsh":["Wind tunnels -- Calibration"],"dc:title":["Design and calibration of a high temperature continuous run electric arc wind tunnel"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Aeronautical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute"]},"updated_at":"2026-11-18T20:10:06Z"}