{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/44257"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/44257","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The effects of end restraint on steel deck reinforced concrete floor systems","abstract":"Extensive research to determine the strength of steel deck reinforced concrete floor systems has been carried out on single-span, single panel width test specimens. Little of this research has considered the benefits that actual field conditions have on overall strength and stiffness. This experimental study investigates typical field details at intermediate supports and end spans. In particular, the influence of adjacent spans and typical pour stop details are considered. Additionally, this study illustrates the applicability of simple analytical models, which can be used to determine the strength and stiffness of steel deck reinforced concrete floor systems.","abstract_html":"Extensive research to determine the strength of steel deck reinforced concrete floor systems has been carried out on single-span, single panel width test specimens. Little of this research has considered the benefits that actual field conditions have on overall strength and stiffness. This experimental study investigates typical field details at intermediate supports and end spans. In particular, the influence of adjacent spans and typical pour stop details are considered. Additionally, this study illustrates the applicability of simple analytical models, which can be used to determine the strength and stiffness of steel deck reinforced concrete floor systems.","abstract_has_math":false,"creators":["Young, Craig S."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1990,"date_issued":"1990","date_published":"1990","updated_at":"2026-11-18T20:07:53Z","subjects":["Flooring, Concrete -- Research"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08182009-040222"],"render_values":[{"text":"etd-08182009-040222","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-08182009-040222/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-08182009-040222/","href":"http://scholar.lib.vt.edu/theses/available/etd-08182009-040222/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/44257","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/44257","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F44257","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Young, Craig S."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-08-18"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:42:54Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:42:54Z","2009-08-18"]},{"key":"dc:date.issued","label":"Date","values":["1990"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-08-18"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1990.Y695.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 23818041"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1990.Y695"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Flooring, Concrete -- Research"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08182009-040222"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-08182009-040222/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/44257"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Extensive research to determine the strength of steel deck reinforced concrete floor systems has been carried out on single-span, single panel width test specimens. Little of this research has considered the benefits that actual field conditions have on overall strength and stiffness. This experimental study investigates typical field details at intermediate supports and end spans. In particular, the influence of adjacent spans and typical pour stop details are considered. Additionally, this study illustrates the applicability of simple analytical models, which can be used to determine the strength and stiffness of steel deck reinforced concrete floor systems."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiii, 144 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The effects of end restraint on steel deck reinforced concrete floor systems"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Young, Craig S."],"dc:date.accepted":["2009-08-18"],"dc:date.accessioned":["2014-03-14T21:42:54Z"],"dc:date.available":["2014-03-14T21:42:54Z","2009-08-18"],"dc:date.issued":["1990"],"dc:date.submitted":["2009-08-18"],"dc:description.abstract":["Extensive research to determine the strength of steel deck reinforced concrete floor systems has been carried out on single-span, single panel width test specimens. Little of this research has considered the benefits that actual field conditions have on overall strength and stiffness. This experimental study investigates typical field details at intermediate supports and end spans. In particular, the influence of adjacent spans and typical pour stop details are considered. Additionally, this study illustrates the applicability of simple analytical models, which can be used to determine the strength and stiffness of steel deck reinforced concrete floor systems."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xiii, 144 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-08182009-040222"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-08182009-040222/"],"dc:identifier.uri":["http://hdl.handle.net/10919/44257"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1990.Y695.pdf"],"dc:relation.isformatof":["OCLC# 23818041"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1990.Y695"],"dc:subject.lcsh":["Flooring, Concrete -- Research"],"dc:title":["The effects of end restraint on steel deck reinforced concrete floor systems"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:07:53Z"}