{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/44494"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/44494","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Physiological and perceptual assessment of thermal comfort and heat strain in garment wear tests using sleeves: an alternative to full-garment tests of chemical protective clothing","abstract":"This study was conducted to explore the feasibility of using sleeves, along with both physiological and perceptual measurements, to assess the thermal comfort and heat strain in chemical protective clothing wear tests. The effect of body sites, i.e. the arms and the chest, and the effect of a Tyvek® coverall on skin temperature and sweat amount were investigated as well. Ten male subjects were selected from college students. Each subject was assigned to wear a garment of either T-shirt and pants or a changeable left-sleeved Tyvek® coverall with or without an experimental sleeve on the left arm. Three experimental sleeves were of the same style, but made of three different fabrics: Tyvek®, Pro/Shield I®, and Pro/Shield II®. Each subject wore an assigned garment and pedaled on a cycle ergometer in an environmentally-controlled room. Skin temperature, sweat amount, and subjective comfort evaluations were recorded and later analyzed by repeated-measures ANOVA. Results showed there is a feasibility in using a sleeve with a T-shirt/pants standard garment for assessing thermal comfort in chemical protective garment wear tests. The T-shirt/pants standard garment yielded more consistent and reliable results than did the Tyvek®-coverall standard garment. Under the same conditions, there were no significant differences in skin temperature and sweat amount among the left and right upper arms and the chest. The Tyvek® sleeve in this study impeded the transfer of heat by the greatest amount, followed by the Pro/Shield II® sleeve and the Pro/Shield I® sleeve, respectively.","abstract_html":"This study was conducted to explore the feasibility of using sleeves, along with both physiological and perceptual measurements, to assess the thermal comfort and heat strain in chemical protective clothing wear tests. The effect of body sites, i.e. the arms and the chest, and the effect of a Tyvek® coverall on skin temperature and sweat amount were investigated as well. Ten male subjects were selected from college students. Each subject was assigned to wear a garment of either T-shirt and pants or a changeable left-sleeved Tyvek® coverall with or without an experimental sleeve on the left arm. Three experimental sleeves were of the same style, but made of three different fabrics: Tyvek®, Pro/Shield I®, and Pro/Shield II®. Each subject wore an assigned garment and pedaled on a cycle ergometer in an environmentally-controlled room. Skin temperature, sweat amount, and subjective comfort evaluations were recorded and later analyzed by repeated-measures ANOVA. Results showed there is a feasibility in using a sleeve with a T-shirt/pants standard garment for assessing thermal comfort in chemical protective garment wear tests. The T-shirt/pants standard garment yielded more consistent and reliable results than did the Tyvek®-coverall standard garment. Under the same conditions, there were no significant differences in skin temperature and sweat amount among the left and right upper arms and the chest. The Tyvek® sleeve in this study impeded the transfer of heat by the greatest amount, followed by the Pro/Shield II® sleeve and the Pro/Shield I® sleeve, respectively.","abstract_has_math":false,"creators":["Tultrairat, Angkhana"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Clothing and Textiles","degree_department":"Clothing and Textiles","school":null,"contributors":[],"advisors":[],"committee_chairs":["Norton, Marjorie","Cloud, Rinn M."],"committee_members":["Boles, Joann F.","Herbert, William G."],"year":1996,"date_issued":"1996","date_published":"1996","updated_at":"2026-11-18T20:21:10Z","subjects":["thermal comfort","heat stress","heat strain","protective clothing","skin temperature","sweat amount"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08292008-063420"],"render_values":[{"text":"etd-08292008-063420","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-08292008-063420/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-08292008-063420/","href":"http://scholar.lib.vt.edu/theses/available/etd-08292008-063420/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/44494","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/44494","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F44494","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Norton, Marjorie","Cloud, Rinn M."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Boles, Joann F.","Herbert, William G."]},{"key":"dc:contributor.department","label":"Department","values":["Clothing and Textiles"]},{"key":"dc:creator","label":"Author","values":["Tultrairat, Angkhana"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2008-08-29"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:44:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:44:02Z","2008-08-29"]},{"key":"dc:date.issued","label":"Date","values":["1996"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2008-08-29"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1996.T858.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 36801828"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Clothing and Textiles"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["thermal comfort","heat stress","heat strain","protective clothing","skin temperature","sweat amount"]},{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1996.T858"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-08292008-063420"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-08292008-063420/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/44494"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This study was conducted to explore the feasibility of using sleeves, along with both physiological and perceptual measurements, to assess the thermal comfort and heat strain in chemical protective clothing wear tests. The effect of body sites, i.e. the arms and the chest, and the effect of a Tyvek® coverall on skin temperature and sweat amount were investigated as well. Ten male subjects were selected from college students. Each subject was assigned to wear a garment of either T-shirt and pants or a changeable left-sleeved Tyvek® coverall with or without an experimental sleeve on the left arm. Three experimental sleeves were of the same style, but made of three different fabrics: Tyvek®, Pro/Shield I®, and Pro/Shield II®. Each subject wore an assigned garment and pedaled on a cycle ergometer in an environmentally-controlled room. Skin temperature, sweat amount, and subjective comfort evaluations were recorded and later analyzed by repeated-measures ANOVA. Results showed there is a feasibility in using a sleeve with a T-shirt/pants standard garment for assessing thermal comfort in chemical protective garment wear tests. The T-shirt/pants standard garment yielded more consistent and reliable results than did the Tyvek®-coverall standard garment. Under the same conditions, there were no significant differences in skin temperature and sweat amount among the left and right upper arms and the chest. The Tyvek® sleeve in this study impeded the transfer of heat by the greatest amount, followed by the Pro/Shield II® sleeve and the Pro/Shield I® sleeve, respectively."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["x, 179 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Physiological and perceptual assessment of thermal comfort and heat strain in garment wear tests using sleeves: an alternative to full-garment tests of chemical protective clothing"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Norton, Marjorie","Cloud, Rinn M."],"dc:contributor.committeemember":["Boles, Joann F.","Herbert, William G."],"dc:contributor.department":["Clothing and Textiles"],"dc:creator":["Tultrairat, Angkhana"],"dc:date.accepted":["2008-08-29"],"dc:date.accessioned":["2014-03-14T21:44:02Z"],"dc:date.available":["2014-03-14T21:44:02Z","2008-08-29"],"dc:date.issued":["1996"],"dc:date.submitted":["2008-08-29"],"dc:description.abstract":["This study was conducted to explore the feasibility of using sleeves, along with both physiological and perceptual measurements, to assess the thermal comfort and heat strain in chemical protective clothing wear tests. The effect of body sites, i.e. the arms and the chest, and the effect of a Tyvek® coverall on skin temperature and sweat amount were investigated as well. Ten male subjects were selected from college students. Each subject was assigned to wear a garment of either T-shirt and pants or a changeable left-sleeved Tyvek® coverall with or without an experimental sleeve on the left arm. Three experimental sleeves were of the same style, but made of three different fabrics: Tyvek®, Pro/Shield I®, and Pro/Shield II®. Each subject wore an assigned garment and pedaled on a cycle ergometer in an environmentally-controlled room. Skin temperature, sweat amount, and subjective comfort evaluations were recorded and later analyzed by repeated-measures ANOVA. Results showed there is a feasibility in using a sleeve with a T-shirt/pants standard garment for assessing thermal comfort in chemical protective garment wear tests. The T-shirt/pants standard garment yielded more consistent and reliable results than did the Tyvek®-coverall standard garment. Under the same conditions, there were no significant differences in skin temperature and sweat amount among the left and right upper arms and the chest. The Tyvek® sleeve in this study impeded the transfer of heat by the greatest amount, followed by the Pro/Shield II® sleeve and the Pro/Shield I® sleeve, respectively."],"dc:description.degree":["Master of Science"],"dc:format.extent":["x, 179 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-08292008-063420"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-08292008-063420/"],"dc:identifier.uri":["http://hdl.handle.net/10919/44494"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1996.T858.pdf"],"dc:relation.isformatof":["OCLC# 36801828"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["thermal comfort","heat stress","heat strain","protective clothing","skin temperature","sweat amount"],"dc:subject.lcc":["LD5655.V855 1996.T858"],"dc:title":["Physiological and perceptual assessment of thermal comfort and heat strain in garment wear tests using sleeves: an alternative to full-garment tests of chemical protective clothing"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Clothing and Textiles"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:21:10Z"}