{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45060"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45060","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Some aspects of vibration serviceability in wood floor systems","abstract":"Two related areas of research are presented in this thesis. In one area, 106 in-situ wood floor systems were subjectively rated and tested to determine fundamental frequency values. This database of wood floor systems was used to provide further validation of a recently proposed design criterion which uses fundamental frequency to predict acceptability of wood floor systems to vibrations resulting from human footfall impacts. Included in the database are floors tested previously unoccupied which were tested again with occupancy loading. Additional occupied and unoccupied wood floor systems not included in the original study were tested. A second area of research was conducted to quantify the changes in frequency content and modal damping values through construction of six typical wood residences. The data from these floors provided insight into the dynamic behavior of wood floor systems and provided further data to validate the above design criterion.","abstract_html":"Two related areas of research are presented in this thesis. In one area, 106 in-situ wood floor systems were subjectively rated and tested to determine fundamental frequency values. This database of wood floor systems was used to provide further validation of a recently proposed design criterion which uses fundamental frequency to predict acceptability of wood floor systems to vibrations resulting from human footfall impacts. Included in the database are floors tested previously unoccupied which were tested again with occupancy loading. Additional occupied and unoccupied wood floor systems not included in the original study were tested. A second area of research was conducted to quantify the changes in frequency content and modal damping values through construction of six typical wood residences. The data from these floors provided insight into the dynamic behavior of wood floor systems and provided further data to validate the above design criterion.","abstract_has_math":false,"creators":["Shue, Bruce C."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":1995,"date_issued":"1995","date_published":"1995","updated_at":"2026-11-18T20:25:03Z","subjects":[],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10072005-094826"],"render_values":[{"text":"etd-10072005-094826","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-10072005-094826/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-10072005-094826/","href":"http://scholar.lib.vt.edu/theses/available/etd-10072005-094826/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/45060","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/45060","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F45060","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Shue, Bruce C."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2005-10-07"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:47:02Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:47:02Z","2005-10-07"]},{"key":"dc:date.issued","label":"Date","values":["1995"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2005-10-07"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1995.S482.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 34371458"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1995.S482"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-10072005-094826"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-10072005-094826/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45060"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Two related areas of research are presented in this thesis. In one area, 106 in-situ wood floor systems were subjectively rated and tested to determine fundamental frequency values. This database of wood floor systems was used to provide further validation of a recently proposed design criterion which uses fundamental frequency to predict acceptability of wood floor systems to vibrations resulting from human footfall impacts. Included in the database are floors tested previously unoccupied which were tested again with occupancy loading. Additional occupied and unoccupied wood floor systems not included in the original study were tested. A second area of research was conducted to quantify the changes in frequency content and modal damping values through construction of six typical wood residences. The data from these floors provided insight into the dynamic behavior of wood floor systems and provided further data to validate the above design criterion."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["x, 138 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Some aspects of vibration serviceability in wood floor systems"]}]}],"canonical_facts":{"dc:contributor.department":["Civil Engineering"],"dc:creator":["Shue, Bruce C."],"dc:date.accepted":["2005-10-07"],"dc:date.accessioned":["2014-03-14T21:47:02Z"],"dc:date.available":["2014-03-14T21:47:02Z","2005-10-07"],"dc:date.issued":["1995"],"dc:date.submitted":["2005-10-07"],"dc:description.abstract":["Two related areas of research are presented in this thesis. In one area, 106 in-situ wood floor systems were subjectively rated and tested to determine fundamental frequency values. This database of wood floor systems was used to provide further validation of a recently proposed design criterion which uses fundamental frequency to predict acceptability of wood floor systems to vibrations resulting from human footfall impacts. Included in the database are floors tested previously unoccupied which were tested again with occupancy loading. Additional occupied and unoccupied wood floor systems not included in the original study were tested. A second area of research was conducted to quantify the changes in frequency content and modal damping values through construction of six typical wood residences. The data from these floors provided insight into the dynamic behavior of wood floor systems and provided further data to validate the above design criterion."],"dc:description.degree":["Master of Science"],"dc:format.extent":["x, 138 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-10072005-094826"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-10072005-094826/"],"dc:identifier.uri":["http://hdl.handle.net/10919/45060"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1995.S482.pdf"],"dc:relation.isformatof":["OCLC# 34371458"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1995.S482"],"dc:title":["Some aspects of vibration serviceability in wood floor systems"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:25:03Z"}