{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45600"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45600","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Analytical modeling of hybrid composite beams","abstract":"The main objective of this study is to develop an analytical model to explain the behavior of a hybrid structure under different loading conditions. The model developed for a simply supported beam on moment capacity, stiffness, and deflection can be generalized to deal with any type of material combination. The dependence of moment capacity of the hybrid beam on the thickness of the composite sheet was investigated. The inherent property of a high Young's modulus and strain-to-failure properties of the composite material increased the moment capacity of the RC beam dramatically. The moment model showed a percentage increase of 284% for KFRP while on the other hand the percentage increases for CFRP and GFRP were 191% and 174% respectively when using a FRP sheet of thickness 0.025 mm. KFRP showed the highest increase in moment capacity because of its high strain-to-failure. CFRP on the other hand has a high Young's modulus, but its strain to failure is low, causing it to lie in the middle range. The analytical model is that the ability of a beam to handle moment is strongly dependent on the strength characteristics and the thickness of the FRP sheet.","abstract_html":"The main objective of this study is to develop an analytical model to explain the behavior of a hybrid structure under different loading conditions. The model developed for a simply supported beam on moment capacity, stiffness, and deflection can be generalized to deal with any type of material combination. The dependence of moment capacity of the hybrid beam on the thickness of the composite sheet was investigated. The inherent property of a high Young&#x27;s modulus and strain-to-failure properties of the composite material increased the moment capacity of the RC beam dramatically. The moment model showed a percentage increase of 284% for KFRP while on the other hand the percentage increases for CFRP and GFRP were 191% and 174% respectively when using a FRP sheet of thickness 0.025 mm. KFRP showed the highest increase in moment capacity because of its high strain-to-failure. CFRP on the other hand has a high Young&#x27;s modulus, but its strain to failure is low, causing it to lie in the middle range. The analytical model is that the ability of a beam to handle moment is strongly dependent on the strength characteristics and the thickness of the FRP sheet.","abstract_has_math":false,"creators":["Bhutta, Salman Ahmed"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Civil Engineering","degree_department":"Civil Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Al-Qadi, Imadeddin L."],"committee_members":["Reifsnider, Kenneth L.","Weyers, Richard E."],"year":1993,"date_issued":"1993-12-06","date_published":"1993-12-06","updated_at":"2026-11-18T20:23:49Z","subjects":["Composite-reinforced concrete","Fibrous composites","Materials -- Dynamic testing"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11102009-020112"],"render_values":[{"text":"etd-11102009-020112","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11102009-020112/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-11102009-020112/","href":"http://scholar.lib.vt.edu/theses/available/etd-11102009-020112/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/45600","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/45600","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F45600","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Al-Qadi, Imadeddin L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Reifsnider, Kenneth L.","Weyers, Richard E."]},{"key":"dc:contributor.department","label":"Department","values":["Civil Engineering"]},{"key":"dc:creator","label":"Author","values":["Bhutta, Salman Ahmed"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2009-11-10"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:49:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:49:23Z","2009-11-10"]},{"key":"dc:date.issued","label":"Date","values":["1993-12-06"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2009-11-10"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1993.B587.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 30443384"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1993.B587"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Composite-reinforced concrete","Fibrous composites","Materials -- Dynamic testing"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11102009-020112"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11102009-020112/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45600"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The main objective of this study is to develop an analytical model to explain the behavior of a hybrid structure under different loading conditions. The model developed for a simply supported beam on moment capacity, stiffness, and deflection can be generalized to deal with any type of material combination. The dependence of moment capacity of the hybrid beam on the thickness of the composite sheet was investigated. The inherent property of a high Young's modulus and strain-to-failure properties of the composite material increased the moment capacity of the RC beam dramatically. The moment model showed a percentage increase of 284% for KFRP while on the other hand the percentage increases for CFRP and GFRP were 191% and 174% respectively when using a FRP sheet of thickness 0.025 mm. KFRP showed the highest increase in moment capacity because of its high strain-to-failure. CFRP on the other hand has a high Young's modulus, but its strain to failure is low, causing it to lie in the middle range. The analytical model is that the ability of a beam to handle moment is strongly dependent on the strength characteristics and the thickness of the FRP sheet."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["x, 101 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Analytical modeling of hybrid composite beams"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Al-Qadi, Imadeddin L."],"dc:contributor.committeemember":["Reifsnider, Kenneth L.","Weyers, Richard E."],"dc:contributor.department":["Civil Engineering"],"dc:creator":["Bhutta, Salman Ahmed"],"dc:date.accepted":["2009-11-10"],"dc:date.accessioned":["2014-03-14T21:49:23Z"],"dc:date.available":["2014-03-14T21:49:23Z","2009-11-10"],"dc:date.issued":["1993-12-06"],"dc:date.submitted":["2009-11-10"],"dc:description.abstract":["The main objective of this study is to develop an analytical model to explain the behavior of a hybrid structure under different loading conditions. The model developed for a simply supported beam on moment capacity, stiffness, and deflection can be generalized to deal with any type of material combination. The dependence of moment capacity of the hybrid beam on the thickness of the composite sheet was investigated. The inherent property of a high Young's modulus and strain-to-failure properties of the composite material increased the moment capacity of the RC beam dramatically. The moment model showed a percentage increase of 284% for KFRP while on the other hand the percentage increases for CFRP and GFRP were 191% and 174% respectively when using a FRP sheet of thickness 0.025 mm. KFRP showed the highest increase in moment capacity because of its high strain-to-failure. CFRP on the other hand has a high Young's modulus, but its strain to failure is low, causing it to lie in the middle range. The analytical model is that the ability of a beam to handle moment is strongly dependent on the strength characteristics and the thickness of the FRP sheet."],"dc:description.degree":["Master of Science"],"dc:format.extent":["x, 101 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-11102009-020112"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-11102009-020112/"],"dc:identifier.uri":["http://hdl.handle.net/10919/45600"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1993.B587.pdf"],"dc:relation.isformatof":["OCLC# 30443384"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1993.B587"],"dc:subject.lcsh":["Composite-reinforced concrete","Fibrous composites","Materials -- Dynamic testing"],"dc:title":["Analytical modeling of hybrid composite beams"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:23:49Z"}