{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45820"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45820","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"Evaluation of activated carbon processes for removing trihalomethane precursors from a surface water impoundment","abstract":"A pilot plant study was conducted in Newport News, Virginia to investigate the effectiveness of powdered activated carbon [PAC] and granular activated carbon [GAC], with and without preoxidation, for reducing trihalomethane [THM] precursor concentrations in Harwood's Mill Reservoir water. Preoxidation with ozone followed by GAC is referred to as the \"biological activated carbon\" [BAC] process. This study showed that the GAC and BAC processes obtained the same level of organic removal; however, BAC would provide longer bed life and require less carbon than the GAC process. PAC treatment of alum coagulated water provided significantly higher TOC and THMFP removals than alum coagulation alone. The use of a preoxidant (ozone) with PAC slightly improved the organic removal efficiency. While treatment by PAC increased THMFP removals, it was not as efficient as the GAC and BAC processes. UV absorbance measured at 254 nm and TOC were found to be good surrogates for THMFP in the GAC column, but not in the BAC column.","abstract_html":"A pilot plant study was conducted in Newport News, Virginia to investigate the effectiveness of powdered activated carbon [PAC] and granular activated carbon [GAC], with and without preoxidation, for reducing trihalomethane [THM] precursor concentrations in Harwood&#x27;s Mill Reservoir water. Preoxidation with ozone followed by GAC is referred to as the &quot;biological activated carbon&quot; [BAC] process. This study showed that the GAC and BAC processes obtained the same level of organic removal; however, BAC would provide longer bed life and require less carbon than the GAC process. PAC treatment of alum coagulated water provided significantly higher TOC and THMFP removals than alum coagulation alone. The use of a preoxidant (ozone) with PAC slightly improved the organic removal efficiency. While treatment by PAC increased THMFP removals, it was not as efficient as the GAC and BAC processes. UV absorbance measured at 254 nm and TOC were found to be good surrogates for THMFP in the GAC column, but not in the BAC column.","abstract_has_math":false,"creators":["Lavinder, Steven Robert"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Environmental Planning","degree_department":"Environmental Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Hoehn, Robert C."],"committee_members":["Novak, John T.","Sroeylok, Vernon"],"year":1987,"date_issued":"1987-06-05","date_published":"1987-06-05","updated_at":"2026-11-18T20:04:49Z","subjects":["Carbon, Activated","Trihalomethanes","Water -- Purification -- Adsorption"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11172012-040344"],"render_values":[{"text":"etd-11172012-040344","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11172012-040344/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-11172012-040344/","href":"http://scholar.lib.vt.edu/theses/available/etd-11172012-040344/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/45820","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/45820","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F45820","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Hoehn, Robert C."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Novak, John T.","Sroeylok, Vernon"]},{"key":"dc:contributor.department","label":"Department","values":["Environmental Engineering"]},{"key":"dc:creator","label":"Author","values":["Lavinder, Steven Robert"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2012-11-17"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:50:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:50:00Z","2012-11-17"]},{"key":"dc:date.issued","label":"Date","values":["1987-06-05"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012-11-17"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1987.L384.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 16796358"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Environmental Planning"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1987.L384"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Carbon, Activated","Trihalomethanes","Water -- Purification -- Adsorption"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11172012-040344"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11172012-040344/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45820"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A pilot plant study was conducted in Newport News, Virginia to investigate the effectiveness of powdered activated carbon [PAC] and granular activated carbon [GAC], with and without preoxidation, for reducing trihalomethane [THM] precursor concentrations in Harwood's Mill Reservoir water. Preoxidation with ozone followed by GAC is referred to as the \"biological activated carbon\" [BAC] process. This study showed that the GAC and BAC processes obtained the same level of organic removal; however, BAC would provide longer bed life and require less carbon than the GAC process. PAC treatment of alum coagulated water provided significantly higher TOC and THMFP removals than alum coagulation alone. The use of a preoxidant (ozone) with PAC slightly improved the organic removal efficiency. While treatment by PAC increased THMFP removals, it was not as efficient as the GAC and BAC processes. UV absorbance measured at 254 nm and TOC were found to be good surrogates for THMFP in the GAC column, but not in the BAC column."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["xiv, 176 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["Evaluation of activated carbon processes for removing trihalomethane precursors from a surface water impoundment"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Hoehn, Robert C."],"dc:contributor.committeemember":["Novak, John T.","Sroeylok, Vernon"],"dc:contributor.department":["Environmental Engineering"],"dc:creator":["Lavinder, Steven Robert"],"dc:date.accepted":["2012-11-17"],"dc:date.accessioned":["2014-03-14T21:50:00Z"],"dc:date.available":["2014-03-14T21:50:00Z","2012-11-17"],"dc:date.issued":["1987-06-05"],"dc:date.submitted":["2012-11-17"],"dc:description.abstract":["A pilot plant study was conducted in Newport News, Virginia to investigate the effectiveness of powdered activated carbon [PAC] and granular activated carbon [GAC], with and without preoxidation, for reducing trihalomethane [THM] precursor concentrations in Harwood's Mill Reservoir water. Preoxidation with ozone followed by GAC is referred to as the \"biological activated carbon\" [BAC] process. This study showed that the GAC and BAC processes obtained the same level of organic removal; however, BAC would provide longer bed life and require less carbon than the GAC process. PAC treatment of alum coagulated water provided significantly higher TOC and THMFP removals than alum coagulation alone. The use of a preoxidant (ozone) with PAC slightly improved the organic removal efficiency. While treatment by PAC increased THMFP removals, it was not as efficient as the GAC and BAC processes. UV absorbance measured at 254 nm and TOC were found to be good surrogates for THMFP in the GAC column, but not in the BAC column."],"dc:description.degree":["Master of Science"],"dc:format.extent":["xiv, 176 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-11172012-040344"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-11172012-040344/"],"dc:identifier.uri":["http://hdl.handle.net/10919/45820"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1987.L384.pdf"],"dc:relation.isformatof":["OCLC# 16796358"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1987.L384"],"dc:subject.lcsh":["Carbon, Activated","Trihalomethanes","Water -- Purification -- Adsorption"],"dc:title":["Evaluation of activated carbon processes for removing trihalomethane precursors from a surface water impoundment"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Environmental Planning"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:04:49Z"}