{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45886"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45886","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"The evaluation of a low powered microwave induced plasma as an atom cell for atomic spectrometry","abstract":"The range of plasma spectroscopy tends to increase with the introduction of more efficient plasma excitation sources. In this thesis the use of one such plasma excitation source, the microwave induced plasma is evaluated as an atom cell for atomic spectrometry. The modes of spectrometry evaluated are atomic emission and atomic fluoresence. Analytical merits of the microwave induced plasma using detection limits and studies of interelement effects (i.e. vaporization, ionizationâ and scatter interferences) are also presented.","abstract_html":"The range of plasma spectroscopy tends to increase with the introduction of more efficient plasma excitation sources. In this thesis the use of one such plasma excitation source, the microwave induced plasma is evaluated as an atom cell for atomic spectrometry. The modes of spectrometry evaluated are atomic emission and atomic fluoresence. Analytical merits of the microwave induced plasma using detection limits and studies of interelement effects (i.e. vaporization, ionizationâ and scatter interferences) are also presented.","abstract_has_math":false,"creators":["Perkins, Larry D."],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Analytical Chemistry","degree_department":"Analytical Chemistry","school":null,"contributors":[],"advisors":[],"committee_chairs":["Long, Gary L."],"committee_members":["McNair, Harold M.","Taylor, Larry T."],"year":1987,"date_issued":"1987-05-15","date_published":"1987-05-15","updated_at":"2026-11-18T20:17:04Z","subjects":["Atomic spectroscopy","Plasma chemistry","Plasma spectroscopy"],"languages":[],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11202012-040034"],"render_values":[{"text":"etd-11202012-040034","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11202012-040034/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-11202012-040034/","href":"http://scholar.lib.vt.edu/theses/available/etd-11202012-040034/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/45886","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/45886","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F45886","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Long, Gary L."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["McNair, Harold M.","Taylor, Larry T."]},{"key":"dc:contributor.department","label":"Department","values":["Analytical Chemistry"]},{"key":"dc:creator","label":"Author","values":["Perkins, Larry D."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2012-11-20"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:50:16Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:50:16Z","2012-11-20"]},{"key":"dc:date.issued","label":"Date","values":["1987-05-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012-11-20"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1987.P474.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 16817900"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Analytical Chemistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1987.P474"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Atomic spectroscopy","Plasma chemistry","Plasma spectroscopy"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11202012-040034"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11202012-040034/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45886"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The range of plasma spectroscopy tends to increase with the introduction of more efficient plasma excitation sources. In this thesis the use of one such plasma excitation source, the microwave induced plasma is evaluated as an atom cell for atomic spectrometry. The modes of spectrometry evaluated are atomic emission and atomic fluoresence. Analytical merits of the microwave induced plasma using detection limits and studies of interelement effects (i.e. vaporization, ionizationâ and scatter interferences) are also presented."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["vii, 64 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["The evaluation of a low powered microwave induced plasma as an atom cell for atomic spectrometry"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Long, Gary L."],"dc:contributor.committeemember":["McNair, Harold M.","Taylor, Larry T."],"dc:contributor.department":["Analytical Chemistry"],"dc:creator":["Perkins, Larry D."],"dc:date.accepted":["2012-11-20"],"dc:date.accessioned":["2014-03-14T21:50:16Z"],"dc:date.available":["2014-03-14T21:50:16Z","2012-11-20"],"dc:date.issued":["1987-05-15"],"dc:date.submitted":["2012-11-20"],"dc:description.abstract":["The range of plasma spectroscopy tends to increase with the introduction of more efficient plasma excitation sources. In this thesis the use of one such plasma excitation source, the microwave induced plasma is evaluated as an atom cell for atomic spectrometry. The modes of spectrometry evaluated are atomic emission and atomic fluoresence. Analytical merits of the microwave induced plasma using detection limits and studies of interelement effects (i.e. vaporization, ionizationâ and scatter interferences) are also presented."],"dc:description.degree":["Master of Science"],"dc:format.extent":["vii, 64 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-11202012-040034"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-11202012-040034/"],"dc:identifier.uri":["http://hdl.handle.net/10919/45886"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1987.P474.pdf"],"dc:relation.isformatof":["OCLC# 16817900"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1987.P474"],"dc:subject.lcsh":["Atomic spectroscopy","Plasma chemistry","Plasma spectroscopy"],"dc:title":["The evaluation of a low powered microwave induced plasma as an atom cell for atomic spectrometry"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Analytical Chemistry"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:17:04Z"}