{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/45960"},"canonical_url":"https://search.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/45960","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A device for the treatment of adult Sleep Apnea Syndrome","abstract":"An electronically-controlled positive-displacement bellows-type air pump has been developed in the Bio-medical Engineering Laboratory for the treatment of adult Sleep Apnea Syndrome (SAS). An electronically-controlled positive-displacement pump has been employed in order to eliminate the pressure regulator and accompanying noise of present therapeutic devices. The positive-displacement pump is found to quietly and effectively provide the required airway pressures for the treatment of adult Sleep Apnea Syndrome. New developments in the reduction of the size and noise levels of current therapeutic devices, however, preclude mass production of the bellows-type pump because of its size disadvantage. The custom nasal mask and exhalation valve, control system, pressure-monitoring alarm system, and the controlled humidifier of the positive-displacement pump should be incorporated within the present fanâ type Nasal Continuous Positive Airway Pressure (NCPAP) system to provide quieter, more comfortable, and safer NCPAP therapy. Before the design and development of the positive displacement NCPAP pump is detailed in this thesis, however, the problem of adult Sleep Apnea Syndrome is introduced, available therapies are investigated, and the current NCPAP therapy system is examined.","abstract_html":"An electronically-controlled positive-displacement bellows-type air pump has been developed in the Bio-medical Engineering Laboratory for the treatment of adult Sleep Apnea Syndrome (SAS). An electronically-controlled positive-displacement pump has been employed in order to eliminate the pressure regulator and accompanying noise of present therapeutic devices. The positive-displacement pump is found to quietly and effectively provide the required airway pressures for the treatment of adult Sleep Apnea Syndrome. New developments in the reduction of the size and noise levels of current therapeutic devices, however, preclude mass production of the bellows-type pump because of its size disadvantage. The custom nasal mask and exhalation valve, control system, pressure-monitoring alarm system, and the controlled humidifier of the positive-displacement pump should be incorporated within the present fanâ type Nasal Continuous Positive Airway Pressure (NCPAP) system to provide quieter, more comfortable, and safer NCPAP therapy. Before the design and development of the positive displacement NCPAP pump is detailed in this thesis, however, the problem of adult Sleep Apnea Syndrome is introduced, available therapies are investigated, and the current NCPAP therapy system is examined.","abstract_has_math":false,"creators":["Wichmann, Mark William"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Arp, Leon J."],"committee_members":["Mitchell, Larry D.","Robertshaw, Harry H."],"year":1988,"date_issued":"1988-07-15","date_published":"1988-07-15","updated_at":"2026-11-18T20:18:55Z","subjects":["Sleep apnea syndromes","Sleep disorders"],"languages":["en"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11212012-040216"],"render_values":[{"text":"etd-11212012-040216","href":null,"code":true}]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11212012-040216/"],"render_values":[{"text":"http://scholar.lib.vt.edu/theses/available/etd-11212012-040216/","href":"http://scholar.lib.vt.edu/theses/available/etd-11212012-040216/","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"http://hdl.handle.net/10919/45960","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"http://hdl.handle.net/10919/45960","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://vtechworks.lib.vt.edu/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Avtechworks.lib.vt.edu%3A10919%2F45960","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Arp, Leon J."]},{"key":"dc:contributor.committeemember","label":"Committee Member","values":["Mitchell, Larry D.","Robertshaw, Harry H."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Wichmann, Mark William"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accepted","label":"Dc Date Accepted","values":["2012-11-21"]},{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2014-03-14T21:50:28Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2014-03-14T21:50:28Z","2012-11-21"]},{"key":"dc:date.issued","label":"Date","values":["1988-07-15"]},{"key":"dc:date.submitted","label":"Dc Date Submitted","values":["2012-11-21"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:relation.haspart","label":"Dc Relation Haspart","values":["LD5655.V855_1988.W538.pdf"]},{"key":"dc:relation.isformatof","label":"Dc Relation Isformatof","values":["OCLC# 18706218"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject.lcc","label":"Dc Subject Lcc","values":["LD5655.V855 1988.W538"]},{"key":"dc:subject.lcsh","label":"Dc Subject Lcsh","values":["Sleep apnea syndromes","Sleep disorders"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-11212012-040216"]},{"key":"dc:identifier.sourceurl","label":"Source URL","values":["http://scholar.lib.vt.edu/theses/available/etd-11212012-040216/"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/45960"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An electronically-controlled positive-displacement bellows-type air pump has been developed in the Bio-medical Engineering Laboratory for the treatment of adult Sleep Apnea Syndrome (SAS). An electronically-controlled positive-displacement pump has been employed in order to eliminate the pressure regulator and accompanying noise of present therapeutic devices. The positive-displacement pump is found to quietly and effectively provide the required airway pressures for the treatment of adult Sleep Apnea Syndrome. New developments in the reduction of the size and noise levels of current therapeutic devices, however, preclude mass production of the bellows-type pump because of its size disadvantage. The custom nasal mask and exhalation valve, control system, pressure-monitoring alarm system, and the controlled humidifier of the positive-displacement pump should be incorporated within the present fanâ type Nasal Continuous Positive Airway Pressure (NCPAP) system to provide quieter, more comfortable, and safer NCPAP therapy. Before the design and development of the positive displacement NCPAP pump is detailed in this thesis, however, the problem of adult Sleep Apnea Syndrome is introduced, available therapies are investigated, and the current NCPAP therapy system is examined."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:format.extent","label":"Dc Format Extent","values":["ix, 93 leaves"]},{"key":"dc:format.medium","label":"Dc Format Medium","values":["BTD"]},{"key":"dc:format.mimetype","label":"Dc Format Mimetype","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["A device for the treatment of adult Sleep Apnea Syndrome"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Arp, Leon J."],"dc:contributor.committeemember":["Mitchell, Larry D.","Robertshaw, Harry H."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Wichmann, Mark William"],"dc:date.accepted":["2012-11-21"],"dc:date.accessioned":["2014-03-14T21:50:28Z"],"dc:date.available":["2014-03-14T21:50:28Z","2012-11-21"],"dc:date.issued":["1988-07-15"],"dc:date.submitted":["2012-11-21"],"dc:description.abstract":["An electronically-controlled positive-displacement bellows-type air pump has been developed in the Bio-medical Engineering Laboratory for the treatment of adult Sleep Apnea Syndrome (SAS). An electronically-controlled positive-displacement pump has been employed in order to eliminate the pressure regulator and accompanying noise of present therapeutic devices. The positive-displacement pump is found to quietly and effectively provide the required airway pressures for the treatment of adult Sleep Apnea Syndrome. New developments in the reduction of the size and noise levels of current therapeutic devices, however, preclude mass production of the bellows-type pump because of its size disadvantage. The custom nasal mask and exhalation valve, control system, pressure-monitoring alarm system, and the controlled humidifier of the positive-displacement pump should be incorporated within the present fanâ type Nasal Continuous Positive Airway Pressure (NCPAP) system to provide quieter, more comfortable, and safer NCPAP therapy. Before the design and development of the positive displacement NCPAP pump is detailed in this thesis, however, the problem of adult Sleep Apnea Syndrome is introduced, available therapies are investigated, and the current NCPAP therapy system is examined."],"dc:description.degree":["Master of Science"],"dc:format.extent":["ix, 93 leaves"],"dc:format.medium":["BTD"],"dc:format.mimetype":["application/pdf"],"dc:identifier.other":["etd-11212012-040216"],"dc:identifier.sourceurl":["http://scholar.lib.vt.edu/theses/available/etd-11212012-040216/"],"dc:identifier.uri":["http://hdl.handle.net/10919/45960"],"dc:language.iso":["en"],"dc:publisher":["Virginia Tech"],"dc:relation.haspart":["LD5655.V855_1988.W538.pdf"],"dc:relation.isformatof":["OCLC# 18706218"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject.lcc":["LD5655.V855 1988.W538"],"dc:subject.lcsh":["Sleep apnea syndromes","Sleep disorders"],"dc:title":["A device for the treatment of adult Sleep Apnea Syndrome"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-11-18T20:18:55Z"}